TIPS for Refractory Ascites: A 6-Year Single-Center Experience With Expanded Polytetrafluoroethylene-Covered Stent-Grafts

被引:29
|
作者
Bercu, Zachary L. [1 ]
Fischman, Aaron M. [1 ]
Kim, Edward [1 ]
Nowakowski, F. Scott [1 ]
Patel, Rahul S. [1 ]
Schiano, Thomas D. [2 ]
Chang, Charissa Y. [2 ]
Lookstein, Robert A. [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Div Intervent Radiol, Dept Radiol, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Recanati Miller Transplantat Inst, Div Liver Dis, New York, NY 10029 USA
关键词
cirrhosis; expanded polytetrafluoroethylene (ePTFE)-covered stent; portal hypertension; refractory ascites; transjugular intrahepatic portosystemic shunt (TIPS); INTRAHEPATIC PORTOSYSTEMIC SHUNT; PARACENTESIS PLUS ALBUMIN; PORTAL-HYPERTENSION; CONSENSUS WORKSHOP; CURRENT MANAGEMENT; COMPLICATIONS; CIRRHOSIS; METAANALYSIS; METHODOLOGY; DIAGNOSIS;
D O I
10.2214/AJR.14.12885
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This single-center study evaluated the use of expanded polytetrafluoroethylene (ePTFE)-covered stent-grafts for transjugular intrahepatic portosystemic shunt (TIPS) placement to manage portal hypertension-related refractory ascites. MATERIALS AND METHODS. One hundred patients at a single tertiary care center in a major metropolitan hospital underwent TIPS placement with an ePTFE-covered stent-graft (Viatorr TIPS Endoprosthesis). Patients with portal hypertension-related ascites and preexisting hepatocellular carcinoma or liver transplant were excluded from the analysis. Records were reviewed for demographic characteristics, technical success of the TIPS procedures, and stent follow-up findings. Clinical results were assessed at 90- and 180-day intervals. RESULTS. Immediate technical success of the TIPS procedure was 100%. Of the 61 patients with documented follow-up, 55 (90.2%) had a partial or complete ascites response to TIPS creation. Of these 55 patients, nine experienced severe encephalopathy. Six of 61 patients (9.8%) did not experience a significant ascites response. Overall survival was 78.7% at 365-day follow-up. The 365-day survival was 84.2% for patients with a model for end-stage liver disease (MELD) score of less than 15, 67.0% for those with a score of 15-18, and 53.8% for those with a score of greater than 18 (p = 0.01). For patients with a MELD score of less than 18, the 365-day survival was 88.0% for those with an albumin value of 3 mg/dL or greater and 72.8% for those with an albumin value of less than 3 mg/dL (p = 0.04). CONCLUSION. TIPS placement using an ePTFE-covered stent-graft is an efficacious therapy for refractory ascites. Patients with preserved liver function-characterized by a MELD score of less than 15 or a MELD score of less than 18 and an albumin value of 3 mg/dL or greater-experience the greatest survival benefit.
引用
收藏
页码:654 / 661
页数:8
相关论文
共 50 条
  • [1] Viatorr TIPS Endoprosthesis Versus Generic Expanded Polytetrafluoroethylene-Covered Stent-Grafts
    Tsauo, Jiaywei
    Li, Xiao
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (04) : W463 - W463
  • [2] Reply to "Viatorr TIPS Endoprosthesis Versus Generic Expanded Polytetrafluoroethylene-Covered Stent-Grafts"
    Bercu, Zachary L.
    Fischman, Aaron M.
    Lookstein, Robert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (04) : W464 - W464
  • [3] COST-EFFECTIVENESS OF EARLY TIPS WITH EXPANDED POLYTETRAFLUOROETHYLENE (EPTFE) COVERED STENT-GRAFTS COMPARED
    Perez-Mitru, A.
    Villacampa Lordan, A.
    Scarpa, F.
    VALUE IN HEALTH, 2016, 19 (07) : A692 - A693
  • [4] TIPS with expanded polytetrafluoroethylene-covered stent: Results of an Italian multicenter study
    Vignali, C
    Bargellini, I
    Grosso, M
    Passalacqua, G
    Maglione, F
    Pedrazzini, F
    Filauri, P
    Niola, R
    Cioni, R
    Petruzzi, P
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 472 - 480
  • [5] Polytetrafluoroethylene-covered stent grafts for TIPS procedure: 1-year patency and clinical results
    Angeloni, S
    Merli, M
    Salvatori, FM
    De Santis, A
    Fanelli, F
    Pepino, D
    Attili, AF
    Rossi, P
    Riggio, O
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (02): : 280 - 285
  • [6] COST-EFFECTIVENESS EVALUATION OF TIPS PROCEDURES WITH EXPANDED POLYTETRAFLUOROETHYLENE (EPTFE) COVERED STENT-GRAFTS COMPARED TO LARGE VOLUME PARACENTESIS IN PATIENTS WITH REFRACTORY ASCITES - A SPANISH SCENARIO
    Perez-Mitru, A.
    Villacampa Lordan, A.
    Scarpa, F.
    VALUE IN HEALTH, 2016, 19 (07) : A693 - A693
  • [7] Refractory Ascites and TIPS with Covered-stents: A Single Center Experience
    Christenson, B.
    Ray, C.
    Gupta, R.
    Kondo, K.
    Forman, L.
    Durham, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [8] Creation of transjugular intrahepatic portosystemic shunts with stent-grafts: Initial experiences with a polytetrafluoroethylene-covered nitinol endoprosthesis
    Cejna, M
    Peck-Radosavljevic, M
    Thurnher, SA
    Hittmair, K
    Schoder, M
    Lammer, J
    RADIOLOGY, 2001, 221 (02) : 437 - 446
  • [9] Expanded polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunts in cirrhotic patients: Long-term patency and clinical outcome results
    Barbara Geeroms
    Wim Laleman
    Annouschka Laenen
    Sam Heye
    Chris Verslype
    Schalk van der Merwe
    Frederik Nevens
    Geert Maleux
    European Radiology, 2017, 27 : 1795 - 1803
  • [10] Limb thrombosis of modular bifurcated aortic stent-grafts: 4-year single-center experience
    Ziegler, P
    Stelter, W
    Umscheid, T
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (02): : 213 - 213