Determination of Methylene Blue and Its Metabolite Residues in Aquatic Products by High-Performance Liquid Chromatography-Tandem Mass Spectrometry

被引:10
|
作者
Zhang, Xuan [1 ,2 ]
Hui, Yunhua [1 ]
Fang, Changling [1 ,2 ]
Wang, Yuan [1 ]
Han, Feng [1 ,2 ]
Lou, Xiaoyi [1 ,2 ]
Fodjo, Essy Kouadio [3 ]
Cai, Youqiong [1 ]
Kong, Cong [1 ,2 ]
机构
[1] Chinese Acad Fishery Sci, East China Sea Fisheries Res Inst, Shanghai 200090, Peoples R China
[2] Chinese Acad Fishery Sci, Key Lab East China, Sea Fisheries Res Inst, Shanghai 200090, Peoples R China
[3] Univ Felix Houphouet Boigny, Phys Chem Lab, UFR SSMT, 22 BP 582, Abidjan, Cote Ivoire
来源
MOLECULES | 2021年 / 26卷 / 16期
关键词
high-performance liquid chromatography-tandem mass spectrometry; methylene blue; disinfectant; aquatic products; VETERINARY DRUG RESIDUES; FISH-TISSUES; DYES; FOOD; TRIARYLMETHANE; PHENOTHIAZINE;
D O I
10.3390/molecules26164975
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and reliable method was developed to determine methylene blue (MB) and its metabolite residues, including azure A (AZA), azure B (AZB), and azure C (AZC) in aquatic products by HPLC-MS/MS. The samples were extracted by acetonitrile and cleaned up by alumina-neutral (ALN) cartridges. The analytes were separated on a Sunfire C18 column (150 mm x 2.1 mm, 5 mu m). The method was validated according to the European criteria of Commission Decision 2002/657/CE. Good linearity between 1-500 mu g/L was obtained with correlation coefficients (R-2) greater than 0.99. The limit of quantification (LOQ) was 1.0 mu g/kg. The average recoveries at three levels of each compound (1, 5, and 10 mu g/kg) were demonstrated to be in the range of 71.8-97.5%, with relative standard deviations (RSDs) from 1.05% to 8.63%. This method was suitable for the detection of methylene blue and its metabolite residues in aquatic products.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Determination of methylene blue residues in aquatic products by liquid chromatography-tandem mass spectrometry
    Xu, Jin-Zhong
    Dai, Lin
    Wu, Bin
    Ding, Tao
    Zhu, Jun-Jie
    Lin, Hong
    Chen, Hui-Lan
    Shen, Chong-Yu
    Jiang, Yuan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (23-24) : 4193 - 4199
  • [2] Determination of Monepantel and Its Metabolite Residues in Dairy Products by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Yingxuan
    Lin, Feng
    Chen, Simin
    [J]. Shipin Kexue/Food Science, 2019, 40 (10): : 325 - 330
  • [3] Determination of metabolite residues of nitrofuran antibiotics in aquatic products by liquid chromatography-tandem mass spectrometry
    Wang Chuanxian
    Huang Fan
    Wang Min
    Sheng Yonggang
    Zhang Jin
    Han Li
    Song Qing
    Li Xiaohong
    Xu Dunming
    Ding Zhuoping
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (03) : 206 - 210
  • [4] Highly Sensitive Determination of Antibiotic Residues in Aquatic Products by High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ye, Hongli
    Li, Siman
    Xi, Yinfeng
    Shi, Yongfu
    Shang, Xiaorui
    Huang, Dongmei
    [J]. ANTIBIOTICS-BASEL, 2022, 11 (10):
  • [5] Determination of Tranquilizer and Their Metabolites Residues in Aquatic Products by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Zhang, Xuan
    Yang, Guang-Xin
    Kong, Cong
    Zhai, Wen-Lei
    Feng, Hua-Feng
    Shen, Xiao-Sheng
    Yu, Hui-Juan
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (03) : 460 - 467
  • [6] Determination of 17α-methyltestosterone in aquatic products using high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Xuan
    Fang, Changling
    Lou, Xiaoyi
    Yang, Guangxin
    Kong, Cong
    Shi, Yongfu
    Huang, Dongmei
    [J]. MICROCHEMICAL JOURNAL, 2022, 183
  • [7] Determination of trichlorfon and dichlorvos residues in aquatic products by liquid chromatography-tandem mass spectrometry
    Huang, Dongmei
    Cai, Youqiong
    Yu, Huijuan
    Shi, Yongfu
    Huang, Xuanyun
    [J]. ADVANCES IN CHEMISTRY RESEARCH II, PTS 1-3, 2012, 554-556 : 1943 - 1946
  • [8] Determination of Matrine and Rotenone Residues in Aquatic Products by Liquid Chromatography-Tandem Mass Spectrometry
    Yang Fang
    Zhen Dan-Ping
    Liu Zhen-Cai
    Lin Yong-Hui
    Chen Jian
    Chen Shou-Ping
    Chen Guo-Nan
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (04) : 556 - 559
  • [9] Determination of 6 Eugenol Residues in Aquatic Products by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Shaoming
    Cai, Xiaoming
    Zhou, Peng
    Cai, Huiqin
    Liang, Min
    Chen, Yankai
    Li, Yanping
    Feng, Lifeng
    Lin, Haoxue
    Huang, Yuan
    [J]. Shipin Kexue/Food Science, 2020, 41 (16): : 320 - 326
  • [10] Determination of etoxazole and its metabolite residues in citrus by ultra-high performance liquid chromatography-tandem mass spectrometry
    Zuo, Wei
    Li, Jing
    Kang, Xiali
    Dong, Chao
    Wang, Chengqiu
    Jiao, Bining
    [J]. Chinese Journal of Analysis Laboratory, 2021, 40 (11) : 1252 - 1256