Pyrometric determination of temperature in rich flames and wavelength dependence of their emissivity

被引:14
|
作者
Block, B
Hentschel, W
Ertmer, W
机构
[1] Volkswagen AG, Res & Dev, D-38436 Wolfsburg, Germany
[2] Univ Hannover, Inst Quantenopt, D-30167 Hannover, Germany
关键词
D O I
10.1016/S0010-2180(97)00294-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new experimental and theoretical method is described to determine the temperature of a rich flame from its luminosity in a time-resolved way. It differs from existing methods in supplying the wavelength dependence of the flame emissivity <(epsilon)over cap>. The light emitted by the combustion is collected by a spectrograph and an image-intensifying streak-camera. Temperatures are derived from the spectral data. This pyrometric method is more precise and more meaningful than previous ones because it is free of any arbitrary assumptions on the wavelength dependence of <(epsilon)over cap>. The experimental scheme is relatively simple and very well suited for various applications. It was tested by investigating a candle light: a butane gas burner, and a series production diesel engine. It yielded temperatures with a total error of about 4%. (C) 1998 by The Combustion Institute.