Effective dose to patient measurements for flat-detector computed tomography protocols in acute stroke care

被引:5
|
作者
Brehm, Alex [1 ]
Stamm, Georg [2 ]
Luepke, Matthias [3 ]
Riedel, Christian [4 ]
Stieltjes, Bram [5 ]
Psychogios, Marios-Nikos [1 ]
机构
[1] Univ Hosp Basel, Clin Radiol & Nucl Med, Dept Neuroradiol, Petersgraben 4, CH-4031 Basel, Switzerland
[2] Univ Med Ctr Goettingen, Dept Radiol, Gottingen, Germany
[3] Univ Vet Med Hannover, Dept Radiol & Med Phys, Hannover, Germany
[4] Univ Med Ctr Goettingen, Dept Neuroradiol, Gottingen, Germany
[5] Univl Hosp Base, Clin Radiol & Nucl Med, Dept Res, Basel, Switzerland
关键词
Cone-beam computed tomography; Stroke; Radiation dosage; Perfusion; Angiography; CT ANGIOGRAPHY; CATARACT; LENS; EYE;
D O I
10.1007/s00330-020-06891-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim was to measure the effective dose of flat-detector CT (FDCT) whole-brain imaging, biphasic FDCT angiography (FDCT-A), and FDCT perfusion (FDCT-P) protocols and compare it to previously reported effective dose values of multidetector CT (MDCT) applications. Materials We measured effective dose according to the IRCP 103 using an anthropomorphic phantom equipped with thermoluminescent dosimeters (TLDs). Placement was according to anatomical positions of each organ. In total, 60 TLDs (>= 4 TLDs/organ) were placed into and onto the phantom to account for all relevant organs. Organs within the primary beam were covered with more TLDs. Additionally, we measured dose to the eye lens with two TLDs per eye. Protocols which we routinely use in clinical practice were measured on a biplane angiography system. Results The effective dose of the 20-s protocol/7-s protocol for whole-brain imaging was 2.6 mSv/2.4 mSv. The radiation dose to the eye lens was 24/23 mGy. For the biphasic high-/low-dose FDCT-A protocol, the effective dose was 8.9/2.8 mSv respectively. The eye lens dose was 60/14 mGy. The contribution of bolus tracking to the effective dose was 0.66 mSv (assuming average duration of 14 s). The multisweep FDCT-P protocol had an effective dose of 5.9 mSv and an eye lens dose of 46 mGy. Conclusion Except for the high-dose biphasic FDCT-A protocol, FDCT applications used in neuroradiology have effective doses, which do not deviate more than 1 mSv from previously reported values for MDCT applications. However, the effective dose to the eye lens in commonly used stroke paradigms exceeds the recommended annual dose twofold.
引用
收藏
页码:5082 / 5088
页数:7
相关论文
共 50 条
  • [1] Effective dose to patient measurements for flat-detector computed tomography protocols in acute stroke care
    Alex Brehm
    Georg Stamm
    Matthias Lüpke
    Christian Riedel
    Bram Stieltjes
    Marios-Nikos Psychogios
    European Radiology, 2020, 30 : 5082 - 5088
  • [2] Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology
    Struffert, Tobias
    Hauer, Michael
    Banckwitz, Rosemarie
    Koehler, Christoph
    Royalty, Kevin
    Doerfler, Arnd
    EUROPEAN RADIOLOGY, 2014, 24 (06) : 1257 - 1265
  • [3] Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology
    Tobias Struffert
    Michael Hauer
    Rosemarie Banckwitz
    Christoph Köhler
    Kevin Royalty
    Arnd Doerfler
    European Radiology, 2014, 24 : 1257 - 1265
  • [4] Flat-detector computed tomography (FD-CT)
    Willi A. Kalender
    Yiannis Kyriakou
    European Radiology, 2007, 17 (11) : 2767 - 2779
  • [5] Flat-detector computed tomography in diagnostic and interventional neuroradiology
    Struffert, T.
    Doerfler, A.
    RADIOLOGE, 2009, 49 (09): : 820 - 829
  • [6] The value of flat-detector computed tomography during catheterisation of congenital heart disease
    Gloeckler, Martin
    Koch, Andreas
    Greim, Verena
    Shabaiek, Amira
    Rueffer, Andre
    Cesnjevar, Robert
    Achenbach, Stephan
    Dittrich, Sven
    EUROPEAN RADIOLOGY, 2011, 21 (12) : 2511 - 2520
  • [7] Intravenous flat-detector CT angiography in acute ischemic stroke management
    Blanc, Raphael
    Pistocchi, Silvia
    Babic, Drazenko
    Bartolini, Bruno
    Obadia, Michael
    Alamowitch, Sonia
    Piotin, Michel
    NEURORADIOLOGY, 2012, 54 (04) : 383 - 391
  • [8] Assessment of cavopulmonary connections by advanced imaging: value of flat-detector computed tomography
    Gloeckler, Martin
    Koch, Andreas
    Halbfass, Julia
    Greim, Verena
    Rueffer, Andre
    Cesnjevar, Robert
    Achenbach, Stephan
    Dittrich, Sven
    CARDIOLOGY IN THE YOUNG, 2013, 23 (01) : 18 - 26
  • [9] The value of flat-detector computed tomography during catheterisation of congenital heart disease
    Martin Glöckler
    Andreas Koch
    Verena Greim
    Amira Shabaiek
    Andrè Rüffer
    Robert Cesnjevar
    Stephan Achenbach
    Sven Dittrich
    European Radiology, 2011, 21 : 2511 - 2520
  • [10] Intravenous flat-detector CT angiography in acute ischemic stroke management
    Raphaël Blanc
    Silvia Pistocchi
    Drazenko Babic
    Bruno Bartolini
    Michaël Obadia
    Sonia Alamowitch
    Michel Piotin
    Neuroradiology, 2012, 54 : 383 - 391