Clinical efficacy of ultrasound-guided hyaluronic acid injections in patients with supraspinatus tendon tear

被引:0
|
作者
Cipolletta, E. [1 ]
Mirza, R. Mashadi [2 ]
Di Matteo, A. [1 ,3 ]
Di Carlo, M. [1 ]
Grassi, W. [1 ]
Filippucci, E. [1 ]
机构
[1] Polytech Univ Marche, Rheumatol Unit, Dept Clin & Mol Sci, Carlo Urbani Hosp, Jesi, Italy
[2] AO Osped Riuniti Marche Nord, Radiol Dept, Pesaro, Italy
[3] Univ Leeds, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
关键词
hyaluronic acid; ultrasonography; interventional ultrasonography; supraspinatus tendon tear; ROTATOR CUFF TEARS; NATURAL-HISTORY; SHOULDER; CORTICOSTEROIDS; BLIND;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the clinical efficacy of ultrasound (US)-guided soft tissue adapted biocompatible hyaluronic acid (STABHA) injections in the subacromial-subdeltoid bursa of patients with supraspinatus tendon tear. Methods In this prospective study, patients with a symptomatic partial-thickness or small full-thickness supraspinatus tendon tear, diagnosed by US, were consecutively enrolled. Patients received one injection at baseline visit and one after 2 weeks and performed rehabilitation therapy. Clinical assessment was performed with visual analogue scale (VAS) for pain, Constant-Murley Scale (CMS), and patient reported efficacy on a 0-4 Likert scale. Patients were examined at baseline, at week 2 and at week 12. Results Thirty patients were enrolled. Sixteen (53.3%) and 19 (63.3%) patients reported significant improvement at week 12 in pain and function, respectively. Reduction in VAS pain was statistically significant both at week 2 and at week 12 in comparison with baseline visit (mean-difference -27.2 and -36.8, respectively, p<0.01). The same trend was observed with CMS (mean-difference 17.7 and 19.8, respectively, p<0.01). At week 12, 18 patients (60.0%) reported a subjective improvement. At week 12, in non-responders (n=14) US detected inflammatory changes and/or progression of tendon tear in 7 (50.0%) patients and no relevant changes in 7 (50.0%). Conclusion US-guided STABHA injections followed by rehabilitation therapy were found effective in improving both pain and shoulder function at the 12-week follow-up. In half of the non-responders, US allowed the detection of US findings responsible for treatment failure.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 50 条
  • [1] Efficacy of ultrasound-guided hyaluronic acid injections in achilles and patellar tendinopathies: a prospective multicentric clinical trial
    Frizziero, A.
    Oliva, F.
    Vittadini, F.
    Vetrano, M.
    Bernetti, A.
    Giordan, N.
    Vulpiani, M. C.
    Santilli, V
    Masiero, S.
    Maffulli, N.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2019, 9 (03): : 305 - 313
  • [2] Efficacy of Ultrasound-Guided Corticosteroid Injections
    Jelsing E.J.
    Finnoff J.T.
    Current Physical Medicine and Rehabilitation Reports, 2016, 4 (2) : 132 - 137
  • [3] Clinical application of ultrasound-guided magnetic resonance arthrography for the diagnosis of supraspinatus tendon tears
    Zhang, Huimei
    Xu, Huajun
    Fan, Huihui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8489 - 8501
  • [4] A Novel Minimally Invasive Ultrasound-Guided Technique to Biopsy Supraspinatus Tendon
    Murphy, Richard J.
    Dean, Benjamin John Floyd
    Wheway, Kim
    Watkins, Bridget
    Morrey, Mark E.
    Carr, Andrew Jonathan
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2013, 23 (02) : 56 - 62
  • [5] Retrospective evaluation of the efficacy of ultrasound-guided intra-articular hyaluronic-acid-based injections (Hyalubrix®) in patients with glenohumeral osteoarthritis
    Monti, Lorenzo
    Franchi, Emanuele
    Verde, Francesco
    Sgherzi, Stefano
    Anghilieri, Filippo Maria
    REUMATISMO, 2025, 77 (01)
  • [6] EFFICACY OF ULTRASOUND-GUIDED INTRA-ARTICULAR INJECTIONS OF PLATELET-RICH PLASMA AND HYALURONIC ACID FOR HIP OSTEOARTHRITIS
    D'Avola, G. M.
    Tropea, S.
    Petralia, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 1186 - 1186
  • [7] Ultrasound-Guided Injection of a Tendon-Compatible Hyaluronic Acid Preparation for the Management of Partial Thickness Rotator Cuff Tear: A Case Report
    Santiago, Mariana
    Goncalves, Filipa
    Martins, Joana
    Lopes, Tiago
    Carvalho, Jose L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [8] The Accuracy of Ultrasound-Guided and Palpation-Guided Peroneal Tendon Sheath Injections
    Muir, Jeffery J.
    Curtiss, Heather M.
    Hollman, John
    Smith, Jay
    Finnoff, Jonathan T.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (07) : 564 - 571
  • [9] Efficacy of ultrasound-guided intra-articular injection with hyaluronic acid for the management of hip osteoarthritis patients
    Zucchi, B.
    Agostini, F.
    Paoloni, M.
    Bernetti, A.
    Mangone, M.
    Zucchi, S.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2021, 35 (04): : 1349 - 1353
  • [10] Efficacy of Ultrasound-guided Intra-articular Injections of Platelet-rich Plasma Versus Hyaluronic Acid for Hip Osteoarthritis
    Battaglia, Milva
    Guaraldi, Federica
    Vannini, Francesca
    Rossi, Giuseppe
    Timoncini, Antonio
    Buda, Roberto
    Giannini, Sandro
    ORTHOPEDICS, 2013, 36 (12) : E1501 - E1508