Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity

被引:258
|
作者
Lamia, Bouchra
Ochagavia, Ana
Monnet, Xavier
Chemla, Denis
Richard, Christian
Teboul, Jean-Louis
机构
[1] Univ Paris 11, Serv Reanimat Med, AP HP, Ctr Hosp Univ Bicetre,EA 4046, F-94270 Le Kremlin Bicetre, France
[2] Univ Paris 11, Serv Explorat Fonctionnelles, AP HP, Ctr Hosp Univ Bicetre,EA 4046, F-94270 Le Kremlin Bicetre, France
关键词
volume responsiveness; passive leg raising; stroke volume; echocardiography; cardiac preload; spontaneous breathing;
D O I
10.1007/s00134-007-0646-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: In hemodynamically unstable patients with spontaneous breathing activity, predicting volume responsiveness is a difficult challenge since the respiratory variation in arterial pressure cannot be used. Our objective was to test whether volume responsiveness can be predicted by the response of stroke volume measured with transthoracic echocardiography to passive leg raising in patients with spontaneous breathing activity. We also examined whether common echocardiographic indices of cardiac filling status are valuable to predict volume responsiveness in this category of patients. Design and setting: Prospective study in the medical intensive care unit of a university hospital. Patients: 24 patients with spontaneously breathing activity considered for volume expansion. Measurements: We measured the response of the echocardiographic stroke volume to passive leg raising and to saline infusion (500ml over 15min). The left ventricular end-diastolic area and the ratio of mitral inflow E wave velocity to early diastolic mitral annulus velocity (E/Ea) were also measured before and after saline infusion. Results: A passive leg raising induced increase in stroke volume of 12.5% or more predicted an increase in stroke volume of 15% or more after volume expansion with a sensitivity of 77% and a specificity of 100%. Neither left ventricular end-diastolic area nor E/Ea predicted volume responsiveness. Conclusions: In our critically ill patients with spontaneous breathing activity the response of echocardiographic stroke volume to passive leg raising was a good predictor of volume responsiveness. On the other hand, the common echocardiographic markers of cardiac filling status were not valuable for this purpose.
引用
收藏
页码:1125 / 1132
页数:8
相关论文
共 50 条
  • [1] Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity
    Bouchra Lamia
    Ana Ochagavia
    Xavier Monnet
    Denis Chemla
    Christian Richard
    Jean-Louis Teboul
    [J]. Intensive Care Medicine, 2007, 33 : 1125 - 1132
  • [2] Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity
    Teboul, Jean-Louis
    Monnet, Xavier
    [J]. CURRENT OPINION IN CRITICAL CARE, 2008, 14 (03) : 334 - 339
  • [3] Assessment of fluid responsiveness in spontaneously breathing critically ill patients
    Renato CF Chaves
    Murillo SC Assunção
    [J]. Critical Care, 19 (Suppl 2):
  • [4] Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
    Soubrier, Stephane
    Saulnier, Fabienne
    Hubert, Herve
    Delour, Pierre
    Lenci, Helene
    Onimus, Thierry
    Nseir, Saad
    Durocher, Alain
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1117 - 1124
  • [5] Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
    Stéphane Soubrier
    Fabienne Saulnier
    Hervé Hubert
    Pierre Delour
    Hélène Lenci
    Thierry Onimus
    Saad Nseir
    Alain Durocher
    [J]. Intensive Care Medicine, 2007, 33 : 1117 - 1124
  • [6] Utilization of stroke volume variation (SVV) in spontaneously breathing critically ill patients to predict fluid responsiveness.
    Grier, Laurie R.
    [J]. CRITICAL CARE MEDICINE, 2006, 34 (12) : A56 - A56
  • [7] Echocardiographic Assessment of Preload Responsiveness in Critically Ill Patients
    Levitov, Alexander
    Marik, Paul E.
    [J]. CARDIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [8] Prediction of fluid responsiveness in spontaneously breathing patients
    Monnet, Xavier
    Teboul, Jean-Louis
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (12)
  • [9] NON-INVASIVE PREDICTION OF VOLUME RESPONSIVENESS USING BIOREACTANCE IN HEMODYNAMICALLY UNSTABLE PATIENTS WITH SPONTANEOUSLY BREATHING ACTIVITY
    Lamia, B.
    Molano, L. -C.
    Cuvelier, A.
    Muir, J. -F.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 : 230 - 230
  • [10] Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients
    Corl, Keith A.
    George, Naomi R.
    Romanoff, Justin
    Levinson, Andrew T.
    Chheng, Darin B.
    Merchant, Roland C.
    Levy, Mitchell M.
    Napoli, Anthony M.
    [J]. JOURNAL OF CRITICAL CARE, 2017, 41 : 130 - 137