Tests on bond of galvanized rebar and concrete cured in seawater

被引:6
|
作者
Andrade, C
Arteaga, A
López-Hombrados, C
Vázquez, A
机构
[1] CSIC, IETcc, Madrid 28033, Spain
[2] CSIC, CENIM, Madrid 28003, Spain
关键词
Bond strength (materials) - Cements - Chlorine - Concrete reinforcements - Galvanizing - Seawater;
D O I
10.1061/(ASCE)0899-1561(2001)13:5(319)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been claimed in the past that one of the main concerns regarding the use of galvanized reinforcement is a possible decrease of the rebar/concrete bond strength. The available results in the literature are contradictory to this. Besides, no long-term-study results have been found. In this paper, a series of tests is presented that compares the bond of deformed bare rebars with galvanized ones, exposed up to 10 years to a chloride environment in natural seawater (Mediterranean). In the case of galvanized rebars, the action of an H-2 inhibitor has been considered as well. The results show that galvanized rebars maintain bond characteristics throughout the test period, with values much higher than the minimum requirements. The addition of an H-2 inhibitor or the use of cements with a high alkali content has shown to be irrelevant in the long term.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [1] Bond Behavior between BFRP Rebar and Seawater Sea Sand Concrete
    Wu, Chao
    Meng, Bing-Chen
    Cheng, Xianfeng
    Korayem, Asghar Habibnejad
    Tam, Lik-Ho
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [2] Heterogeneous crystallization of zinc hydroxystannate on galvanized steel for enhancing the bond strength at the rebar/concrete interface
    Di Franco, Francesco
    Zaffora, Andrea
    Megna, Bartolomeo
    Santamaria, Monica
    CHEMICAL ENGINEERING JOURNAL, 2021, 405
  • [3] Passivation Mechanism of Galvanized Steel Rebar in Fresh Concrete
    Maeda, Mari
    Li, Xiuyang
    Ooi, Azusa
    Tada, Eiji
    Nishikata, Atsushi
    ISIJ INTERNATIONAL, 2020, 60 (02) : 337 - 345
  • [4] Modelling bond of GFRP rebar and concrete
    Rezazadeh, Mohammadali
    Carvelli, Valter
    Veljkovic, Ana
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 153 : 102 - 116
  • [5] Numerical modelling of the concrete/rebar bond
    Phan, Thanh Song
    Rossi, Pierre
    Tailhan, Jean-Louis
    CEMENT & CONCRETE COMPOSITES, 2015, 59 : 1 - 9
  • [6] BOND OF GALVANIZED STEEL REINFORCEMENT IN CONCRETE
    BIRD, CE
    NATURE, 1962, 194 (4830) : 798 - &
  • [7] Corrosion of rebar in concrete using seawater as mixing water
    Yamaji, Toru
    Miyasaka, Matsuho
    Husain, Adel
    Zairyo to Kankyo/ Corrosion Engineering, 2019, 68 (10): : 284 - 287
  • [8] Bond Strength of FRP Rebar to Concrete: Effect of Concrete Confinement
    Quayyum, Shahriar
    Rteil, Ahmad
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 581 - 584
  • [9] Bond of ribbed galvanized reinforcing steel in concrete
    Kayali, O
    Yeomans, SR
    CEMENT & CONCRETE COMPOSITES, 2000, 22 (06): : 459 - 467
  • [10] Improving the bond strength between steel rebar and concrete by oxidation treatments of the rebar
    Fu, X
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 1996, 26 (10) : 1499 - 1503