Assessment of corroded reinforced concrete beams: Cyclic load test and acoustic emission techniques

被引:18
|
作者
Shahid, K. A. [1 ,2 ]
Bunnori, N. Muhammad [3 ]
Johari, M. A. Megat [1 ]
Hassan, Mohd H. [1 ]
Sani, Ashiru [1 ]
机构
[1] Univ Sains Malaysia, Sch Civil Engn, Engn Campus, Nibong Tebal 14300, Pulau Pinang, Malaysia
[2] Univ Malaysia Pahang, Fac Civil Engn & Earth Resources, Kuantan 26300, Pahang, Malaysia
[3] Univ Malaya, Dept Civil Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
关键词
Acoustic emission; Reinforced concrete; Corrosion; Cyclic load test; Structural health monitoring; DAMAGE ASSESSMENT; CORROSION; CLASSIFICATION; CRACKING; STEEL; IDENTIFICATION; MECHANISMS; FRACTURE; AID;
D O I
10.1016/j.conbuildmat.2019.117291
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An acoustic emission (AE) technique has been used to monitor different initial conditions of corroded reinforced concrete beams under a cyclic load test (CLT) in accordance with ACI 437. Limited studies have assessed the validity of this test method for corroded reinforced concrete structural members, especially in a full-scale specimen. This study aimed to explore damage evaluation techniques based on CLT acceptance criteria and AE damage quantification techniques under different initial conditions of corroded reinforced concrete beam specimens. The beam specimens were subjected to three different corrosion durations (15, 30 and 45 days), to reflect the different extents of corrosion, which was accelerated using the impressed current method with 3.5% NaCl solution. This study also discussed the results obtained by both methods. Deviation from linearity (DFL) failed after loadset 3 based on the CLT acceptance criteria corresponding to the first visible crack in all of the specimens. The AE data analysis revealed that the cumulative signal strength (CSS) ratio was useful for identifying minor damage, whereas the felicity and calm ratios were suitable for determining moderate to heavy damage. Relaxation ratio analysis could be effectively performed to identify damage that corresponded to the first visible crack. Analysis on both methods showed that the DFL and relaxation ratio could be effectively used for damage identification because both methods corresponded to the first visible crack. Nonetheless, the AE method offered more advantages including damage detection and progression. Therefore, this method is promising for non-destructive evaluation in structural health monitoring. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Evaluation of strengthened reinforced concrete beams: Cyclic load test and acoustic emission methods
    Ridge, Adam R.
    Ziehl, Paul H.
    ACI STRUCTURAL JOURNAL, 2006, 103 (06) : 832 - 841
  • [2] Application of acoustic emission monitoring for assessment of bond performance of corroded reinforced concrete beams
    Abouhussien, Ahmed A.
    Hassan, Assem A. A.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2017, 16 (06): : 732 - 744
  • [3] Vibration monitoring and acoustic emission sensing during progressive load tests of corroded reinforced concrete beams
    van de Velde, Menno
    Vandecruys, Eline
    Verstrynge, Els
    Reynders, Edwin
    Lombaert, Geert
    ENGINEERING STRUCTURES, 2024, 306
  • [4] Evaluation of Reinforced Concrete Beam Specimens with Acoustic Emission and Cyclic Load Test Methods
    Liu, Zhiwei
    Ziehl, Paul H.
    ACI STRUCTURAL JOURNAL, 2009, 106 (03) : 288 - 299
  • [5] Damage Characteristics and Crack Monitoring of Corroded Reinforced Concrete Beams in Bending Process Based on Acoustic Emission Techniques
    Pan T.
    Zheng Y.
    Xu X.
    Lan X.
    Zhou Y.
    Tongji Daxue Xuebao/Journal of Tongji University, 2024, 52 (03): : 350 - 359
  • [6] Damage assessment of reinforced concrete beams qualified by acoustic emission
    Ohtsu, M
    Uchida, M
    Okamoto, T
    Yuyama, S
    ACI STRUCTURAL JOURNAL, 2002, 99 (04) : 411 - 417
  • [7] Acoustic emission characteristics of corroded reinforced concrete columns under low-cyclic loading
    Shaojie C.
    Jianxi R.
    Qiang L.
    Guang Y.
    Peilin Y.
    Journal of Engineering Science and Technology Review, 2019, 12 (03) : 21 - 29
  • [8] Acoustic Emission Assessment of Corroded RC Columns Jointly Reinforced with Concrete Canvas and CFRP
    Wang, Jingsong
    Niu, Jiangang
    Xiang, Zehui
    Zhou, Jie
    Wang, Jun
    COATINGS, 2022, 12 (12)
  • [9] LOAD CARRYING CAPACITY OF CORRODED REINFORCED CONCRETE BEAMS SUBJECTED TO REPEATED LOAD
    Fang, Congqi
    Yi, Meiying
    Cheng, Shujian
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2008, 22 (31-32): : 5515 - 5520
  • [10] LOAD CARRYING CAPACITY OF CORRODED REINFORCED CONCRETE BEAMS SUBJECTED TO REPEATED LOAD
    Fang, Congqi
    Yi, Meiying
    Cheng, Shujian
    ENGINEERING PLASTICITY AND ITS APPLICATIONS: FROM NANOSCALE TO MACROSCALE, 2009, : 143 - 148