A Simple Technique for Imaging the Human Skeleton Using a Flatbed Scanner

被引:2
|
作者
Fox, Sherry C. [1 ]
Eliopoulos, Constantine [2 ]
Moutafi, Ioanna [3 ]
Manolis, Sotiris K. [4 ]
机构
[1] Amer Sch Class Studies Athens, Wiener Lab, GR-10676 Athens, Greece
[2] Liverpool John Moores Univ, Sch Nat Sci & Psychol, Res Ctr Evolutionary Anthropol & Palaeoecol, Liverpool L3 3AF, Merseyside, England
[3] Univ Sheffield, Dept Archaeol, Sheffield S1 4ET, S Yorkshire, England
[4] Univ Athens, Sch Sci, Fac Biol, Dept Anim & Human Physiol, GR-15701 Athens, Greece
来源
关键词
forensic science; forensic anthropology; digital image; scanner; photographic documentation; Lovejoy aging method; AGE;
D O I
10.1111/j.1556-4029.2010.01596.x
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A simple technique for imaging the human skeleton with a flatbed scanner is presented using the auricular surface of the ilium as an example. A flatbed scanner with resolution capabilities of 600 dpi or greater allows for images of human bones. The auricular surface of the ilium was selected to demonstrate this technique as it is a fairly three-dimensional area that can be difficult to record photographically. Fifty left ilia of various ages at death from the Athens Collection were selected from which three observers (SCF, CE, and IM) scored the morphology of the auricular surface using a well-established aging method. Observations were taken of the dry bone, of digital photographs of the bone, and of scanned images of the bone, and in that sequence. Results indicate that scores of scanned images are equivalent or better than digital images of the same ilia. This technique allows for sharing data electronically with ease.
引用
收藏
页码:S154 / S157
页数:4
相关论文
共 50 条
  • [1] Rapid, simple quantitation in thin-layer chromatography using a flatbed scanner
    Johnson, ME
    JOURNAL OF CHEMICAL EDUCATION, 2000, 77 (03) : 368 - 372
  • [2] Simple assessment of needleleaf and broadleaf chlorophyll content using a flatbed color scanner
    Eitel, Jan U. H.
    Vierling, Lee A.
    Long, Dan S.
    Litvak, Marcy
    Eitel, Karla C. B.
    CANADIAN JOURNAL OF FOREST RESEARCH, 2011, 41 (07) : 1445 - 1451
  • [3] Shadow moire topography using a flatbed scanner
    Ng, TW
    Tajuddin, A
    OPTICAL ENGINEERING, 2002, 41 (08) : 1908 - 1911
  • [4] Nitrite Quantification in Water Using a Flatbed Scanner
    Fabris, B. T.
    Joao, J. J.
    Borges, E. M.
    REVISTA VIRTUAL DE QUIMICA, 2020, 12 (03) : 569 - 582
  • [5] 0.5 gigapixel microscopy using a flatbed scanner
    Zheng, Guoan
    Ou, Xiaoze
    Yang, Changhuei
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 1 - 8
  • [6] A simple approach to fine wire diameter measurement using a high-resolution flatbed scanner
    C. W. Kee
    M. M. Ratnam
    The International Journal of Advanced Manufacturing Technology, 2009, 40 : 940 - 947
  • [7] QUANTIFICATION OF DOCKAGE IN CANOLA USING A FLATBED SCANNER
    Dilawari, G.
    Jones, C. L.
    TRANSACTIONS OF THE ASABE, 2013, 56 (05) : 1969 - 1975
  • [8] Quantification of dockage in canola using a flatbed scanner
    Jones, C.L. (jcarol@okstate.edu), 1969, American Society of Agricultural and Biological Engineers (56):
  • [9] Classification of cereal grains using a flatbed scanner
    Paliwal, J.
    Borhan, M.S.
    Jayas, D.S.
    Canadian Biosystems Engineering / Le Genie des biosystems au Canada, 2004, 46 : 1 - 3
  • [10] A simple approach to fine wire diameter measurement using a high-resolution flatbed scanner
    Kee, C. W.
    Ratnam, M. M.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 40 (9-10): : 940 - 947