Self Calibrating pressure sensor for biomedical applications

被引:0
|
作者
Yameogo, P. [1 ]
Heiba, U. [1 ]
Al Bahri, M. [2 ]
Pons, P. [2 ]
机构
[1] Univ Toulouse 3, Lab Anal & Architecture Syst, F-31062 Toulouse, France
[2] CNRS, LAAS, Lab Anal & Architecture Syst, Toulouse, France
关键词
INTRACRANIAL-PRESSURE; DEVICES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we present for the first time a wireless self calibrating pressure sensor for biomedical applications. The proposed system consists of a piezoresistive pressure sensor implemented on a thin silicon membrane, a catheter tube and finally a protection capsule fabricated from a biocompatible polymer (PEEK). A double side flex with embedded conductors has been used to create the interconnections between the pressure sensor and the control circuit which is further connected to a wireless transceiver. The auto calibration capability of the proposed sensor enables to avoid the existing problem of drift with time and hence provides an excellent solution for long term monitoring. Moreover, the catheter of the proposed system has a reduced length of only 200mm in comparison to the 1m length for the existing wired solutions.
引用
收藏
页码:693 / +
页数:2
相关论文
共 50 条
  • [1] Self-calibrating pressure sensor for biomedical applications
    Yameogo, P.
    Pons, P.
    Vardon, G.
    Schmidt, E.
    [J]. IRBM, 2011, 32 (02) : 145 - 147
  • [2] A micromachined pressure sensor for biomedical applications
    Bistue, G
    Elizalde, JG
    GarciaAlonso, I
    Olaizola, S
    Castano, E
    Gracia, FJ
    GarciaAlonso, A
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) : 244 - 246
  • [3] ELECTROLYTIC PRESSURE SENSOR FOR BIOMEDICAL APPLICATIONS
    HOK, B
    GROTH, O
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 738 - &
  • [4] An implantable capacitive pressure sensor for biomedical applications
    Chiang, Chia-Chu
    Lin, Chou-Ching K.
    Ju, Ming-Shuang
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (02) : 382 - 388
  • [5] Analysis of Tongue Pressure Sensor for Biomedical Applications
    Sardini, E.
    Serpelloni, M.
    Pandini, S.
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 60 - 64
  • [6] Fiber optic pressure sensor for biomedical applications
    Narendran, N
    Corbo, MA
    Smith, W
    [J]. ASAIO JOURNAL, 1996, 42 (05) : M500 - M506
  • [7] A telemetric pressure sensor system for biomedical applications
    Ginggen, Alec
    Tardy, Yanik
    Crivelli, Rocco
    Bork, Toralf
    Renaud, Philippe
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (04) : 1374 - 1381
  • [8] Nanocomposite flexible pressure sensor for biomedical applications
    Sepulveda, A. T.
    Fachin, F.
    de Villoria, R. Guzman
    Wardle, B. L.
    Viana, J. C.
    Pontes, A. J.
    Rocha, L. A.
    [J]. EUROSENSORS XXV, 2011, 25
  • [9] Development of an Implantable Capacitive Pressure Sensor for Biomedical Applications
    Roh, Ji-Hyoung
    Shin, Kyu-Sik
    Song, Tae-Ha
    Kim, Jihong
    Lee, Dae-Sung
    [J]. MICROMACHINES, 2023, 14 (05)
  • [10] Interface pressure sensor for IVRA and other biomedical applications
    Casey, V
    O'Sullivan, S
    McEwen, JA
    [J]. MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) : 177 - 182