Detection of Arcing and High Impedance with Electrical Weapons

被引:0
|
作者
Chiles, Bryan D. [1 ]
Nerheim, Max H. [2 ]
Markle, Ryan C. [3 ]
Brave, Michael A. [2 ]
Panescu, Dorin [4 ]
Kroll, Mark W. [5 ]
机构
[1] Axon Enterprise Inc, Axon, Scottsdale, AZ 85255 USA
[2] Axon, Scottsdale, AZ USA
[3] LAAW Int LLC, Mesa, AZ USA
[4] HeartBeam Inc, Santa Clara, CA USA
[5] Calif Polytech Univ, Biomed Engn, San Luis Obispo, CA USA
关键词
POLICE USE;
D O I
10.1109/EMBC46164.2021.9629836
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Conducted electrical weapons are primarily designed to stop subjects from endangering themselves or others by deploying 2, or more, probes to conduct current via the body to induce motor-nerve mediated muscle contractions, but probe impedance can vary significantly including open circuits from probes failing to complete or maintain a circuit. Methods: We tested 10 units of the TASER (R) 7 model with a range of impedances and open circuit conditions. Pulse data (stored in the device's memory) were used to predict the load resistances and detect arcing conditions. Acoustical data (recorded externally) was evaluated on an exploratory basis as a secondary goal. Results: The average error of predicted resistance, over the physiological load range of 400-1000 Omega, was 8% Arcing conditions was predicted with an accuracy of 97%. An arcing condition increases the duration of the sound generation. Conclusions: The TASER 7 electronic control device stored pulse-log data for charge and arc voltage yielded forensic analysis of the load resistance with reliable accuracy.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 50 条
  • [1] DETECTION OF HIGH IMPEDANCE ARCING FAULTS USING A MULTILAYER PERCEPTRON
    SULTAN, AF
    SWIFT, GW
    FEDIRCHUK, DJ
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) : 1871 - 1877
  • [2] Wavelet transform in the accurate detection of high impedance arcing faults in high voltage transmission lines
    Kim, CH
    Kim, H
    Aggarwal, RK
    Johns, AT
    [J]. SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 422 - 425
  • [3] New insight into the detection of high-impedance arcing faults on DC trolley systems
    Li, JC
    Kohler, JL
    [J]. IAS '96 - CONFERENCE RECORD OF THE 1996 IEEE INDUSTRY APPLICATIONS CONFERENCE, THIRTY-FIRST IAS ANNUAL MEETING, VOLS 1-4, 1996, : 2506 - 2513
  • [4] New insight into the detection of high-impedance arcing faults an dc trolley systems
    Li, JC
    Kohler, JL
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (05) : 1169 - 1173
  • [5] A novel selectivity technique for high impedance arcing fault detection in compensated MV networks
    Elkalashy, Nagy I.
    Lehtonen, Matti
    Darwish, Hatem A.
    Taalab, Abdel-Maksoud I.
    Izzularab, Mohamed A.
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2008, 18 (04): : 344 - 363
  • [6] Study on High Impedance Fault Arcing Current Characteristics
    Chen, J. C.
    Phung, B. T.
    Zhang, D. M.
    Blackburn, T.
    Ambikairajah, E.
    [J]. 2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [7] Detection of High Impedance Faults in Electrical Power Network
    Aliouat, Sihem
    Korzet, Wafia
    Nacer, Azzedine
    Boudjit, Kamel
    Moulai, Houcine
    [J]. 3RD INTERNATIONAL CONFERENCE ON CONTROL, ENGINEERING & INFORMATION TECHNOLOGY (CEIT 2015), 2015,
  • [8] IMPEDANCE CHANGES DURING CATHETER ABLATION AND THEIR RELATIONSHIP TO ELECTRICAL ARCING AND CLINICAL EFFICACY
    CUNNINGHAM, D
    AHSAN, AJ
    ROWLAND, E
    RICKARDS, AF
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01): : 144 - 149
  • [9] Detection of series arcing in low-voltage electrical installations
    Hadziefendic, Nedzad
    Kostic, Miomir
    Radakovic, Zoran
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (03): : 423 - 432
  • [10] Discussion of "A novel fault detection technique of high impedance arcing faults in transmission lines using the wavelet transform"
    Lazkano, A
    Ruiz, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) : 1596 - 1596