A simplified model for evaluating the energy saving potential of adopting demand controlled ventilation in office buildings in Hong Kong

被引:3
|
作者
Jia, Jie [1 ]
Lee, Wai-Ling [1 ]
Chen, Hua [2 ]
Li, Han [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin, Peoples R China
关键词
Demand controlled ventilation; Energy saving; In situ measurements; Site surveys; Building energy simulations; Simplified model; INDOOR AIR-QUALITY; VALIDATION; STRATEGY; SYSTEMS;
D O I
10.1177/1420326X16666620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Demand controlled ventilation (DCV) to conserve energy while maintaining an acceptable indoor environment has been used for over 30 years. However, little work has been done on evaluating its energy saving potential in cooling dominant office buildings in subtropical climate. In this study, the energy saving potential of DCV system for use in six representative office buildings in Hong Kong was investigated by simulations. Simulation validation was done based on in situ measurements and site surveys. The findings show that, based on their original design conditions, the use of DCV could lead to 12.5-26.1% energy saving. To facilitate quick estimation of the energy saving potential of DCV system, further simulations were performed for the development of a simplified model. The simplified model relates the energy saving potential to key air-conditioning system and design parameters. Based on the simplified model, sensitivity analysis was conducted to quantify the influences of different parameters on the energy saving potential of DCV system. The developed model method can be used for prediction on the energy saving potential in a wider application of DCV in Hong Kong.
引用
收藏
页码:47 / 58
页数:12
相关论文
共 50 条
  • [1] Evaluating the use heat pipe for dedicated ventilation of office buildings in Hong Kong
    Zhang, Lian
    Lee, W. L.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (04) : 1983 - 1989
  • [2] Analysis of energy saving potential in commercial buildings of Hong Kong
    Yang Jia
    Chan Kwok-tai
    Wu Xiang-sheng
    Yang Xiao-feng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2006, 13 : 60 - 64
  • [3] The rising energy efficiency of office buildings in Hong Kong
    Jia, Jie
    Lee, W. L.
    ENERGY AND BUILDINGS, 2018, 166 : 296 - 304
  • [4] A parametric analysis on energy and cost saving potentials of implementing demand side management (DSM) measures in Hong Kong's office buildings
    Ng, Ivan W.H.
    Deng, Shiming
    HKIE Transactions Hong Kong Institution of Engineers, 2002, 9 (03): : 34 - 38
  • [5] A study of energy efficiency of private office buildings in Hong Kong
    Chung, William
    Hui, Y. V.
    ENERGY AND BUILDINGS, 2009, 41 (06) : 696 - 701
  • [6] Simplified predicting models on Energy-saving Potential of Indirect Evaporative Coolers in Hong Kong
    Min Yunran
    Chen Yi
    Yang Hongxing
    RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID, 2019, 159 : 225 - 230
  • [7] A discussion on potentials of saving energy use for commercial buildings in Hong Kong
    Yu, Philip C. H.
    Chow, W. K.
    ENERGY, 2007, 32 (02) : 83 - 94
  • [8] Energy saving by realistic design data for commercial buildings in Hong Kong
    Lee, WL
    Yik, FWH
    Jones, P
    Burnett, J
    APPLIED ENERGY, 2001, 70 (01) : 59 - 75
  • [9] Energy Saving by Utilizing Natural Ventilation in Public Housing in Hong Kong
    Yik, Francis W. H.
    Lun, Yu Fat
    INDOOR AND BUILT ENVIRONMENT, 2010, 19 (01) : 73 - 87
  • [10] A study on energy performance of 30 commercial office buildings in Hong Kong
    Jing, Rui
    Wang, Meng
    Zhang, Ruoxi
    Li, Ning
    Zhao, Yingru