Performance and design analyses of various configurations of dew point evaporative cooling-based desiccant air-conditioning (DAC) systems for hot and humid conditions

被引:1
|
作者
Lao, Marco [1 ]
Lin, Jie [2 ]
Miksik, Frantisek [1 ,3 ]
Thu, Kyaw [1 ,3 ]
Miyazaki, Takahiko [1 ,3 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
[2] UCL, Dept Chem Engn, Gower St, London WC1 6BT, England
[3] Kyushu Univ, Res Ctr Next Generat Refrigerant Properties NEXT, Int Inst Carbon Neutral Energy Res WPI I2CNER, Nishi Ward, 744 Motooka, Fukuoka 8190385, Japan
关键词
Desiccant air-conditioning; Dew point evaporative cooling; Space cooling; Regeneration temperature; Waste heat; Thermal comfort; SOLID-DESICCANT; COUNTER-FLOW; MAISOTSENKO CYCLE; DEHUMIDIFICATION;
D O I
10.1007/s44189-022-00011-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermally driven desiccant- and evaporative cooling-based technologies are promising greener and cheaper alternatives to compressor-based systems due to the separate handling of latent and sensible loads. Desiccant air-conditioning (DAC) systems comprise a desiccant dehumidifier, a sensible cooling unit, a heat source for regeneration, and a heat recovery unit. These components of a DAC system can be arranged in various ways to give different configurations with varying advantages and disadvantages. In this study, five configurations of thermally driven desiccant dehumidifier- and dew point evaporative cooling (DPEC)-based DAC systems were investigated. Seven evaluation criteria namely regeneration temperature, desiccant moisture removal capacity, COPt, DPEC L/H, heat exchanger UA, system size, and fan power requirement were employed. Results show that the standard cycle in ventilation mode offers the highest COPt despite having the highest regeneration temperature. Recirculation of the return room air can operate at a significantly lower regeneration temperature at the expense of larger equipment size and much lower COPt. DAC with an internally cooled dehumidification can operate at low regeneration temperature at the expense of higher fan power and slightly lower COPt. Dividing the dehumidification process into two stages can offer operation at moderately lower regeneration temperature without severely affecting the other criteria. This study can serve as a guide for the selection of an appropriate DAC configuration for space cooling depending on the objective criteria and the resources available.
引用
收藏
页数:14
相关论文
共 12 条
  • [1] Performance and design analyses of various configurations of dew point evaporative cooling-based desiccant air-conditioning (DAC) systems for hot and humid conditions
    Marco Lao
    Jie Lin
    František Mikšík
    Kyaw Thu
    Takahiko Miyazaki
    [J]. International Journal of Air-Conditioning and Refrigeration, 30
  • [2] Performance assessment of a desiccant air-conditioning system combined with dew-point indirect evaporative cooler and PV/T
    Olmus, Umutcan
    Guzelel, Yunus Emre
    Pinar, Engin
    Ozbek, Arif
    Buyukalaca, Orhan
    [J]. SOLAR ENERGY, 2022, 231 : 566 - 577
  • [3] Influence of the process and regeneration air conditions on the thermal performance of various desiccant air-conditioning systems
    Omar, Hani
    Sajjad, Uzair
    Hussain, Imtiyaz
    Bhat, Showkat Ahmad
    Sultan, Muhammad
    Ali, Hafiz Muhammad
    Hamid, Khalid
    Yan, Wei-Mon
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2024, 22
  • [4] Life cycle assessment of desiccant-Dew point evaporative cooling systems with water reclamation for poultry houses in hot and humid climate
    Harrouz, Jean Paul
    Katramiz, Elvire
    Ghali, Kamel
    Ouahrani, Djamel
    Ghaddar, Nesreen
    [J]. APPLIED THERMAL ENGINEERING, 2022, 210
  • [5] Exergy analysis of hybrid air-conditioning systems with different evaporative-cooling condensers under hot-humid climates
    Yang, Yang
    Yang, Boyu
    Zeng, Jun
    Yin, Linmao
    Xie, Zhiyi
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [6] Performance study on a hybrid solid desiccant-vapor compression air-conditioning system for hot-humid ambient conditions
    Venkatesh, R.
    Ganesh, Madhu
    Rudramoorthy, R.
    [J]. HEAT TRANSFER, 2024, : 507 - 529
  • [7] Application of desiccant systems for improving the performance of an evaporative cooling-assisted 100% outdoor air system in hot and humid climates
    Kim, Min-Hwi
    Park, Joon-Young
    Park, Jun-Seok
    Jeong, Jae-Weon
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2015, 8 (03) : 173 - 190
  • [8] Experimental assessment of the energy performance of a renewable air-cooling unit based on a dew-point indirect evaporative cooler and a desiccant wheel
    Romero-Lara, Maria Jesus
    Comino, Francisco
    de Adana, Manuel Ruiz
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 310
  • [9] Energy Performance of Liquid Desiccant and Evaporative Cooling-Assisted 100% Outdoor Air Systems under Various Climatic Conditions
    Li, Shiying
    Jeong, Jae-Weon
    [J]. ENERGIES, 2018, 11 (06):
  • [10] Solar-Powered Air Conditioning for Buildings in Hot Climates: Desiccant Evaporative Cooling vs. Absorption Chiller-based Systems
    Brumana, Giovanni
    Franchini, Giuseppe
    [J]. 71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016), 2016, 101 : 288 - 296