Simultaneous Quantification of Plasma Catecholamines and Metanephrines by LC-MS/MS

被引:2
|
作者
Dikunets, Marina [1 ]
Dudko, Grigory [1 ]
Glagovsky, Pavel [2 ]
Mamedov, Ilgar [2 ]
机构
[1] Fed State Budgetary Inst Fed Sci Ctr Phys Culture, Moscow 105005, Russia
[2] OOO ChromsystemsLab, Moscow 119049, Russia
关键词
catecholamines; metanephrines; LC-MS/MS; plasma; overtraining; pheochromocytoma; TANDEM MASS-SPECTROMETRY; PHEOCHROMOCYTOMA; PERFORMANCE; DIAGNOSIS; NOREPINEPHRINE; EPINEPHRINE; METABOLISM; EXTRACTION; PARAMETERS; SEPARATION;
D O I
10.21577/0103-5053.20200033
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The quantification of the low levels of catecholamines and metanephrines in biological fluids is important for clinical screening of pheochromocytoma/paraganglioma and diagnosis of overtraining syndrome in athletes. We introduce a novel, accurate and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of these biogenic amines in human plasma. Simple protein precipitation combined with rapid 2-aminoethyl diphenylborinate-assisted liquid-liquid extraction allow us to quantify catecholamines and metanephrines over broad concentration ranges. Target analytes were monitored in positive electrospray ionization mode by multiple reaction monitoring. Method performance was validated for linearity, lower limit of quantification, limit of detection, intra-day and inter-assay precision, carry-over. recovery, and matrix effect. The assay was linear within analytical range 25-1000 pg mL(-1) for epinephrine, 30-2500 pg mL(-1) for norepinephrine. 15-1000 pg mL(-1) for dopamine. 25-2000 pg mL(-1) for metanephrine and 50-10000 pg mL(-1) for normetanephrine, with lower limits of quantification of 15, 20, 10, 15 and 30 pg mL(-1), respectively. The intra- and inter-day precisions for all compounds ranged from 0.4 to 6.9% and from 0.9 to 6.6%, respectively. The efficiency of novel method was confirmed by assaying external quality control samples which demonstrated consistent and accurate results.
引用
收藏
页码:1467 / 1474
页数:8
相关论文
共 50 条
  • [1] In Matrix Derivatization Combined with LC-MS/MS Results in Ultrasensitive Quantification of Plasma Free Metanephrines and Catecholamines
    van Faassen, Martijn
    Bischoff, Rainer
    Eijkelenkamp, Karin
    de Jong, Wilhelmina H. A.
    van der Ley, Claude P.
    Kema, Ido P.
    ANALYTICAL CHEMISTRY, 2020, 92 (13) : 9072 - 9078
  • [2] LC-MS based simultaneous profiling of adrenal hormones of steroids, catecholamines, and metanephrines
    Noh, Jongsung
    Lee, Chaelin
    Kim, Jung Hee
    Myung, Seung Woon
    Choi, Man Ho
    JOURNAL OF LIPID RESEARCH, 2023, 64 (11)
  • [3] Simultaneous quantification of thalidomide, lenalidomide and pomadomide in plasma by LC-MS/MS
    Wang, Bin
    Qiang, Wanting
    Yi, Jia
    Gao, Shouhong
    Meng, Bosu
    Mu, Yuhui
    Wang, Bolong
    Wang, Zhipeng
    Tao, Xia
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2023, 120
  • [4] Performance characteristics of an LC-MS/MS method for the determination of plasma metanephrines
    Petteys, Brian J.
    Graham, Kendon S.
    Parnas, M. Laura
    Holt, Crystal
    Frank, Elizabeth L.
    CLINICA CHIMICA ACTA, 2012, 413 (19-20) : 1459 - 1465
  • [5] An LC-MS/MS method for the simultaneous quantification of 32 steroids in human plasma
    Simkova, Marketa
    Kolatorova, Lucie
    Drasar, Pavel
    Vitku, Jana
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1201
  • [6] Highly sensitive LC-MS/MS analysis of catecholamines in plasma
    Bergmann, Marianne L.
    Schmedes, Anne
    CLINICAL BIOCHEMISTRY, 2020, 82 : 51 - 57
  • [7] Measurements of plasma metanephrines by immunoassay versus LC-MS/MS for diagnosis of pheochromocytoma
    Weismann, D.
    Raida, A.
    Deutschbein, T.
    Prejbisz, A.
    Januszewicz, A.
    Willenberg, H. S.
    Peitzsch, M.
    Daerr, R.
    Klemm, R.
    Manz, G.
    Bidlingmaier, M.
    Eisenhofer, G.
    Fassnacht, M.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2014, 122 (03)
  • [8] Simultaneous Quantification of Baricitinib and Methotrexate in at Plasma by LC-MS/MS: Application to a Pharmacokinetic Study
    Veeraraghavan, Sridhar
    Thappali, Satheeshmanikandan R. S.
    Viswanadha, Srikant
    Vakkalanka, Swaroop
    Rangaswamy, Manivannan
    SCIENTIA PHARMACEUTICA, 2016, 84 (02) : 347 - 359
  • [9] Development of an LC-MS/MS method for the simultaneous quantification of aripiprazole and dehydroaripiprazole in human plasma
    Song, Min
    Xu, Xinxin
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    ANALYTICAL BIOCHEMISTRY, 2009, 385 (02) : 270 - 277
  • [10] Simultaneous quantification of 51 steroids in pediatric plasma and urine samples by LC-MS/MS
    Wu, Xiaoyu
    Chen, Yao
    Li, Xiaoqing
    Xue, Peng
    Tang, Jingyi
    Yu, Xiaodan
    Zheng, Liang
    Wang, Xiumin
    Liu, Shijian
    HORMONE RESEARCH IN PAEDIATRICS, 2022, 95 (SUPPL 2): : 370 - 371