Acquisition of Priori Tissue Optical Structure Based on Non-rigid Image Registration

被引:0
|
作者
Wan, Wenbo [1 ]
Li, Jiao [1 ,2 ]
Liu, Lingling [1 ]
Wang, Yihan [1 ]
Zhang, Yan [1 ]
Gao, Feng [1 ,2 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Key Lab Biomed Detecting Tech & Instrumen, Tianjin 300072, Peoples R China
来源
关键词
Priori tissue optical structure; Mouse model; Non-rigid image registration; Shape-parameterized diffuse optical tomography;
D O I
10.1117/12.2075710
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Shape-parameterized diffuse optical tomography (DOT), which is based on a priori that assumes the uniform distribution of the optical properties in the each region, shows the effectiveness of complex biological tissue optical heterogeneities reconstruction. The priori tissue optical structure could be acquired with the assistance of anatomical imaging methods such as X-ray computed tomography (XCT) which suffers from low-contrast for soft tissues including different optical characteristic regions. For the mouse model, a feasible strategy of a priori tissue optical structure acquisition is proposed based on a non-rigid image registration algorithm. During registration, a mapping matrix is calculated to elastically align the XCT image of reference mouse to the XCT image of target mouse. Applying the matrix to the reference atlas which is a detailed mesh of organs/tissues in reference mouse, registered atlas can be obtained as the anatomical structure of target mouse. By assigning the literature published optical parameters of each organ to the corresponding anatomical structure, optical structure of the target organism can be obtained as a priori information for DOT reconstruction algorithm. By applying the non-rigid image registration algorithm to a target mouse which is transformed from the reference mouse, the results show that the minimum correlation coefficient can be improved from 0.2781 (before registration) to 0.9032 (after fine registration), and the maximum average Euclid distances can be decreased from 12.80mm (before registration) to 1.02mm (after fine registration), which has verified the effectiveness of the algorithm.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Non-rigid Image Registration with Spatial Structure Preservation
    Bi, Dongsheng
    Zhu, Yanhui
    2018 26TH INTERNATIONAL CONFERENCE ON GEOINFORMATICS (GEOINFORMATICS 2018), 2018,
  • [2] A non-rigid cardiac image registration method based on an optical flow model
    Lu, Xiaoqi
    Zhao, Yongjie
    Zhang, Baohua
    Wu, Jianshuai
    Li, Na
    Jia, Weitao
    OPTIK, 2013, 124 (20): : 4266 - 4273
  • [3] Study on Non-rigid Medical Image Registration Based on Optical Flow Model
    Lu Xiaoqi
    Zhao Yongjie
    Zhang Baohua
    Ma Hongli
    2012 INTERNATIONAL WORKSHOP ON IMAGE PROCESSING AND OPTICAL ENGINEERING, 2012, 8335
  • [4] A Non-rigid Image Registration Algorithm Based on NURBS
    Wang, Jingjing
    Wang, Hongjun
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 3521 - +
  • [5] Multimodal non-rigid image registration based on elastodynamics
    Ahmad, Sahar
    Khan, Muhammad Faisal
    VISUAL COMPUTER, 2018, 34 (01): : 21 - 27
  • [6] Multimodal non-rigid image registration based on elastodynamics
    Sahar Ahmad
    Muhammad Faisal Khan
    The Visual Computer, 2018, 34 : 21 - 27
  • [7] Non-rigid Image Registration with Uniform Spherical Structure Patterns
    Liao, Shu
    Chung, Albert C. S.
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 163 - 175
  • [8] Rigid and non-rigid medical image registration methods
    Dhawan, Atam P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 200 - 219
  • [9] Non-Rigid Multimodal Image Registration Based on Local Variability Measures and Optical Flow
    Reducindo, I.
    Arce-Santana, E.
    Campos-Delgado, D. U.
    Vigueras-Gomez, F.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1133 - 1136
  • [10] A Non-rigid Multimodal Image Registration Method Based on Particle Filter and Optical Flow
    Arce-Santana, Edgar
    Campos-Delgado, Daniel U.
    Alba, Alfonso
    ADVANCES IN VISUAL COMPUTING, PT I, 2010, 6453 : 35 - 44