Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

被引:4
|
作者
Van Keer, Karel [1 ]
Van Keer, Jan [2 ]
Breda, Joao Barbosa [1 ]
Nassiri, Vahid [3 ]
De Deyne, Cathy [4 ,5 ]
Genbrugge, Cornelia [4 ,5 ]
Pinto, Luis Abegao [6 ]
Stalmans, Ingeborg [1 ,7 ]
Vandewalle, Evelien [1 ]
机构
[1] Univ Hosp Leuven, Dept Ophthalmol, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Cardiol, Leuven, Belgium
[3] Katholieke Univ Leuven, I BioStat, Leuven, Belgium
[4] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium
[5] Ziekenhuis Oost Limburg, Dept Anesthesiol Intens Care Emergency Med & Pain, Genk, Belgium
[6] Ctr Hosp Lisboa Norte, Dept Ophthalmol, Lisbon, Portugal
[7] Katholieke Univ Leuven, Lab Ophthalmol, Dept Ophthalmol Neurosci, Leuven, Belgium
来源
PLOS ONE | 2018年 / 13卷 / 01期
关键词
NEAR-INFRARED SPECTROSCOPY; BLOOD-FLOW; THERAPEUTIC HYPOTHERMIA; CARDIOPULMONARY BYPASS; VENOUS CONTRIBUTIONS; HEALTHY-SUBJECTS; CARDIAC-SURGERY; SATURATION; ARTERIAL; METABOLISM;
D O I
10.1371/journal.pone.0190612
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO(2-retinal)) and venous (SvO(2-retinal)) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial: venous ratio as 0.3 x SaO(2-retinal) + 0.7 x SvO(2-retinal). The individual relative weight of SaO(2-retinal) and SvO(2-retinal) to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 +/- 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO(2-retinal) and SvO(2-retinal) (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO(2-retinal) and SvO(2-retinal) to obtain SO2-transcranial were 0.31 +/- 0.11 and 0.69 +/- 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial: venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Retinal oximetry as a novel parameter in the non-invasive assessment of cerebral oxygenation
    Van Keer, Karel
    De Deyne, Cathy
    Genbrugge, Cornelia
    Pinto, Luis
    Vandewalle, Evelien
    Stalmans, Ingeborg
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] A SYSTEM FOR NON-INVASIVE OXIMETRY OF RETINAL-VESSELS
    DELORI, FC
    ROGERS, FJ
    BURSELL, SE
    PARKER, JS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (08) : 604 - 604
  • [3] Non-invasive trans-abdominal monitoring of petal cerebral oxygenation using pulse oximetry
    Zourabian, A
    Siegel, A
    Ramanujam, N
    Chance, B
    Boas, DA
    Vishnoi, BG
    Choe, R
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 669 - 675
  • [4] Cerebral oximetry: another blow to non-invasive monitoring?
    Kunst, G.
    Milan, Z.
    [J]. ANAESTHESIA, 2017, 72 (12) : 1435 - 1438
  • [5] Non-invasive optical monitoring of cerebral oxygenation.
    Hintz, SR
    Benaron, DA
    Duckworth, JL
    Rhine, WD
    Cheong, WF
    Robbins, RC
    Stevenson, DK
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 1998, 46 (01) : 96A - 96A
  • [6] COMPARISON OF NON-INVASIVE METHODS OF ESTIMATING OXYGENATION IN INFANTS - TCO2 VS EAR OXIMETRY
    KRAUSS, AN
    WALDMAN, S
    FRAYER, WW
    AULD, PAM
    [J]. PEDIATRIC RESEARCH, 1977, 11 (04) : 573 - 573
  • [7] Non-invasive imaging of retinal blood flow and oximetry by a new retinal function imager
    Aloni, EH
    Pollack, A
    Grinvald, A
    Vanzetta, I
    Nelson, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U599 - U599
  • [8] Non-invasive cardiac output and cerebral oximetry compared with traditional measures
    Minnick, N.
    Wirnmer, C. J.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : S48 - S48
  • [9] Use of retinal oximetry in estimating cerebral tissue oxygenation
    Van Keer, K.
    Pinto, L. Abegao
    Stalmans, I.
    Vandewalle, E.
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93
  • [10] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Nils H. Petersen
    Santiago Ortega-Gutierrez
    Andres Reccius
    Arjun Masurkar
    Amy Huang
    Randolph S. Marshall
    [J]. Neurocritical Care, 2014, 20 : 60 - 68