A numerical analysis of continuous glucose monitoring method using a microdialysis technique

被引:0
|
作者
Koseki, O [1 ]
Tamura, T [1 ]
Sumino, T [1 ]
Ogawa, M [1 ]
Togawa, T [1 ]
Tsuchiya, K [1 ]
机构
[1] Waseda Univ, Dept Mech Engn, Shinjuku Ku, Tokyo 1698555, Japan
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Monitoring of subcutaneous tissue glucose concentration is an attractive tool to detect a continuous glucose concentration, and has been studied by several researchers. We have proposed a new method, which can measure the concentration of subcutaneous tissue continuously, even when the recovery rate and the biosensor output current decreased. Two reference solutions were prepared with concentrations above and below the object concentration. These were perfused alternately with the some ratio of two periods. The output detected at the sensor, multiplied by the constant gain, was provided as feedback to the ratio. The glucose concentration in the subcutaneous tissue was calculated using the ratio of the two perfusion periods. To analyze the diffusion between the microdialysis probe and subcutaneous tissue, a compartment model was established. The numerical study was performed with a compartment model and control theory. In the simulation, the 90 % response time to step change was about 7 min, which is fast enough when compared with the sharp fluctuations of a blood glucose level. This result suggested that our method was effective.
引用
收藏
页码:1771 / 1774
页数:4
相关论文
共 50 条
  • [1] Continuous on-line glucose monitoring using pattern recognition: the comparative microdialysis technique
    Hoss, U
    Gessler, R
    Kalatz, B
    Sternberg, F
    Salgado, M
    Lohmann, S
    Fussgaenger, RD
    DIABETES, 1999, 48 : A103 - A104
  • [2] A method for continuous glucose monitoring in interstitial fluid based on microdialysis
    Li, D. (dchli@tju.edu.cn), 1600, Tianjin University (46):
  • [3] Ex vivo continuous glucose monitoring with microdialysis technique:: The example of GlucoDay
    Ricci, Francesco
    Moscone, Danila
    Palleschi, Giuseppe
    IEEE SENSORS JOURNAL, 2008, 8 (1-2) : 63 - 70
  • [4] Continuous glucose monitoring by intravenous microdialysis
    Rooyackers, O.
    Blixt, C.
    Mattsson, P.
    Wernerman, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (07) : 841 - 847
  • [5] Microdialysis system for continuous glucose monitoring
    Steinkuhl, R
    Sundermeier, C
    Hinkers, H
    Dumschat, C
    Cammann, K
    Knoll, M
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 19 - 24
  • [6] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72
  • [7] INVIVO CONTINUOUS MONITORING OF GLUCOSE BY MICRODIALYSIS AND A GLUCOSE BIOSENSOR
    MASCINI, M
    MOSCONE, D
    BERNARDI, L
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) : 143 - 145
  • [8] A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)
    Poscia, A
    Mascini, M
    Moscone, D
    Luzzana, M
    Caramenti, G
    Cremonesi, P
    Valgimigli, F
    Bongiovanni, C
    Varalli, M
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (07): : 891 - 898
  • [9] Preliminary study of calibration-free continuous glucose monitoring with microdialysis technique
    Sumino, OT
    Tamura, T
    Koseki, K
    Nawata, M
    Ogawa, M
    Togawa, T
    Tsuchiya, K
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1775 - 1778
  • [10] A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2)
    Varalli, M
    Marelli, G
    Maran, A
    Bistoni, S
    Luzzana, M
    Cremonesi, P
    Caramenti, G
    Valgimigli, F
    Poscia, A
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (07): : 899 - 905