Small-volume radial flow cell for all-solid-state ion-selective electrodes

被引:30
|
作者
Vázquez, M [1 ]
Bobacka, J [1 ]
Ivaska, A [1 ]
Lewenstam, A [1 ]
机构
[1] Abo Akad Univ, Proc Chem Grp, Ctr Proc Analyt Chem & Sensor Technol ProSens, FIN-20500 Turku, Finland
关键词
flow cell; ion-selective electrode; conducting polymer; poly(3,4-ethylenedioxythiophene); Baytron P; clinical analysis;
D O I
10.1016/S0039-9140(03)00408-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow cell with a radial distribution of four all-solid-state ion selective electrodes (ISEs), or alternatively three ISEs and one reference electrode, was designed and optimized for mass production. The radial distribution of the electrodes reduces the cell volume and is expected to minimize cross-contamination between different electrodes. Two different cell prototypes were developed and tested for all-solid-state K+-ISEs based on a solvent polymeric ion-selective membrane (ISM) and a conducting polymer, poly(3,4-ethylenedioxythiophene), as solid internal contact. In the first prototype, PEDOT was electropolymerized from an aqueous solution of the monomer and the doping ion salt, sodium polystyrenesulfonate (NaPSS). The second prototype employed an aqueous dispersion of PEDOT(PSS) that is commercially available (Baytron P. Bayer AG). Compared to electrochemical synthesis, solution casting of the polymer dispersion was found to be a more advantageous method to deposit the conducting polymer layer aiming at mass production. The resulting prototypes of the flow cell had a small volume (ca. 17-37 mul), which makes them suitable for application in clinical analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] All-solid-state ion-selective electrodes for determining amiodarone
    Kholoshenko N.M.
    Ryasenskii S.S.
    Gorelov I.P.
    Pharmaceutical Chemistry Journal, 2006, 40 (5) : 289 - 292
  • [2] All-solid-state ion-selective electrodes reversible to propranolol
    Kartamyshev S.V.
    Kuznetsova M.V.
    Ryasenskii S.S.
    Gorelov I.P.
    Pharmaceutical Chemistry Journal, 2005, 39 (1) : 43 - 45
  • [3] Rational design of all-solid-state ion-selective electrodes and reference electrodes
    Hu, Jinbo
    Stein, Andreas
    Buehlmann, Philippe
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 76 : 102 - 114
  • [4] All-Solid-State Ion-Selective Electrodes: A Tutorial for Correct Practice
    Criscuolo, Francesca
    Hanitra, Mandresy Ivan Ny
    Taurino, Irene
    Carrara, Sandro
    De Micheli, Giovanni
    IEEE SENSORS JOURNAL, 2021, 21 (20) : 22143 - 22154
  • [5] All-Solid-State Ion Selective and All-Solid-State Reference Electrodes
    Michalska, Agata
    ELECTROANALYSIS, 2012, 24 (06) : 1253 - 1265
  • [6] ALL-SOLID-STATE FLUORIDE ELECTRODE AND PROSPECTS OF DEVELOPING SOLID-STATE ION-SELECTIVE ELECTRODES
    LYALIN, OO
    TURAEVA, MS
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1976, 31 (10): : 1356 - 1361
  • [7] All-solid-state ion-selective electrodes with ion-to-electron transducers for dopamine determination
    Kholoshenko N.M.
    Ryasenskii S.S.
    Gorelov I.P.
    Pharmaceutical Chemistry Journal, 2006, 40 (6) : 334 - 336
  • [8] Application of polyaniline nanofibers for the construction of nitrate all-solid-state ion-selective electrodes
    Pietrzak, Karolina
    Wardak, Cecylia
    Malinowski, Szymon
    APPLIED NANOSCIENCE, 2021, 11 (12) : 2823 - 2835
  • [9] Application of polyaniline nanofibers for the construction of nitrate all-solid-state ion-selective electrodes
    Karolina Pietrzak
    Cecylia Wardak
    Szymon Malinowski
    Applied Nanoscience, 2021, 11 : 2823 - 2835
  • [10] Robust fabrication of nanomaterial-based all-solid-state ion-selective electrodes
    Liu, Kaikai
    Jiang, Xiaojing
    Song, Yuehai
    Liang, Rongning
    RSC ADVANCES, 2019, 9 (29) : 16713 - 16717