Membrane filtration for particles removal after ozonation-biofiltration

被引:5
|
作者
Osterhus, S. [1 ]
Azrague, K. [1 ]
Leiknes, T. [1 ]
Odegaard, H. [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Hydraul & Environm Engn, N-7491 Trondheim, Norway
关键词
biofiltration; drinking water treatment; fouling; membrane filtration; ozonation;
D O I
10.2166/wst.2007.780
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the process combination Ozonation-Biofiltration-Membranefiltration (the OBM-process) an average removal of 63% for UV-absorbance (UV254), 79% for color, and 28% for DOC was obtained treating NOM containing surface water. In this paper, focus has been made on the removal of particles after the ozonation and biofiltration treatment steps, using a submerged hollow fiber ultrafiltration membrane reactor. For this purpose the membrane performed adequately. The ultrafiltration step did not have a significant impact on the removal of color, UV254, and DOC. However, the SS and the heterotrophic plate count (HPC) was almost completely removed, and the turbidity was reduced by 65% by the membrane filtration, even at very high fluxes. Fouling occurred during operation, and operational factors of both the ozonation/biofiltration and the membrane reactor were important for controlling this. The experiments at pH 6.5 gave a higher permanent fouling than at pH 8.5, which was caused by the different oxidation pathways and consequently by the change in size and hydrophobicity of the by-products. On the other hand, the reversible fouling was less important at low pH. The mechanical cleaning was efficient, however, it seemed that the air scouring participated to the formation of submicron particles which favored the fouling.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 50 条
  • [1] Removal of humic acids by the ozonation-biofiltration process
    Seredynska-Sobecka, Boena
    Tomaszewska, Maria
    Morawski, Antoni W.
    DESALINATION, 2006, 198 (1-3) : 265 - 273
  • [2] Formation and removal of biodegradable ozonation by-products during ozonation-biofiltration treatment: Pilot-scale evaluation
    Griffini, O
    Bao, ML
    Barbieri, K
    Burrini, D
    Santianni, D
    Pantani, F
    OZONE-SCIENCE & ENGINEERING, 1999, 21 (01) : 79 - 98
  • [3] Study on control of Trihalomethane Formation potential in Ozonation-Biofiltration Process
    Huang Jian-jun
    Zhang Zhao-hui
    2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 3, PROCEEDINGS, 2009, : 543 - +
  • [4] Investigating machine learning models to predict microbial activity during ozonation-biofiltration
    Farzanehsa, Mahshid S. Z.
    Carvajal, Guido
    Mieog, John
    Khan, Stuart J.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2023, 9 (02) : 396 - 405
  • [5] NOM - Removal by biofiltration after ozonation - Results of a pilot plant test
    Wricke, B
    Petzoldt, H
    Heiser, H
    Bornmann, K
    ADVANCES IN SLOW SAND AND ALTERNATIVE BIOLOGICAL FILTRATION, 1996, : 51 - 60
  • [6] The development of an ozonation/biofiltration process for the removal of humic substances
    Odegaard, H
    ADVANCES IN SLOW SAND AND ALTERNATIVE BIOLOGICAL FILTRATION, 1996, : 39 - 49
  • [7] Removal of micropollutants from water by ozonation/biofiltration process
    Seredynska-Sobecka, B
    Tomaszewska, M
    Morawski, AW
    DESALINATION, 2005, 182 (1-3) : 151 - 157
  • [8] Effect of Membrane Filtration on Ozonation Efficiency for Removal of Atrazine from Surface Water
    Luis, Patricia
    Saquib, Mohd
    Vinckier, Chris
    Van der Bruggen, Bart
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (14) : 8686 - 8692
  • [9] Ozonation, biofiltration and the role of membrane surface charge and hydrophobicity in removal and destruction of algal toxins at basic pH values
    Eke, Joyner
    Wagh, Priyesh
    Escobar, Isabel C.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 194 : 56 - 63
  • [10] Combining Ozonation and Ceramic Membrane Filtration for Tertiary Treatment
    Stueber, Johan
    Miehe, Ulf
    Stein, Robert
    Koehler, Mirco
    Lesjean, Boris
    CHEMIE INGENIEUR TECHNIK, 2013, 85 (08) : 1237 - 1242