Heat stress in chemical protective clothing: porosity and vapour resistance

被引:57
|
作者
Havenith, George [1 ]
den Hartog, Emiel [2 ]
Martini, Svein [3 ]
机构
[1] Univ Loughborough, Environm Ergon Res Ctr, Loughborough Design Sch, Loughborough LE11 3TU, Leics, England
[2] TNO, CBRN Protect, NL-2280 AA Rijswijk, Netherlands
[3] Norwegian Def Res Estab, Forsvarets Forskningsinst, N-2007 Kjeller, Norway
关键词
chemical protection; clothing; evaporative resistance; heat strain; PPE; ENSEMBLES; VENTILATION; PERMEABILITY; RESPONSES; HUMIDITY; STRAIN; WORK;
D O I
10.1080/00140139.2011.558638
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Heat strain in chemical protective clothing is an important factor in industrial and military practice. Various improvements to the clothing to alleviate strain while maintaining protection have been attempted. More recently, selectively permeable membranes have been introduced to improve protection, but questions are raised regarding their effect on heat strain. In this paper the use of selectively permeable membranes with low vapour resistance was compared to textile-based outer layers with similar ensemble vapour resistance. For textile-based outer layers, the effect of increasing air permeability was investigated. When comparing ensembles with a textile vs. a membrane outer layer that have similar heat and vapour resistances measured for the sum of fabric samples, a higher heat strain is observed in the membrane ensemble, as in actual wear, and the air permeability of the textile version improves ventilation and allows better cooling by sweat evaporation. For garments with identical thickness and static dry heat resistance, but differing levels of air permeability, a strong correlation of microclimate ventilation due to wind and movement with air permeability was observed. This was reflected in lower values of core and skin temperatures and heart rate for garments with higher air permeability. For heart rate and core temperature the two lowest and the two highest air permeabilities formed two distinct groups, but they did not differ within these groups. Based on protection requirements, it is concluded that air permeability increases can reduce heat strain levels allowing optimisation of chemical protective clothing.
引用
收藏
页码:497 / 507
页数:11
相关论文
共 50 条
  • [1] CHEMICAL PROTECTIVE CLOTHING AND HEAT-STRESS
    WHITE, MK
    RONK, R
    PROFESSIONAL SAFETY, 1984, 29 (12): : 34 - 38
  • [2] PROTECTIVE CLOTHING AND HEAT-STRESS
    HOLMER, I
    ERGONOMICS, 1995, 38 (01) : 166 - 182
  • [3] Protective clothing and heat stress: Introduction
    Crockford, GW
    ANNALS OF OCCUPATIONAL HYGIENE, 1999, 43 (05): : 287 - 288
  • [4] Effects of chemical protective clothing and heat stress on army helicopter pilot performance
    Caldwell, JL
    Caldwell, JA
    Salter, CA
    MILITARY PSYCHOLOGY, 1997, 9 (04) : 315 - 328
  • [5] EFFECT OF HEAT AND CHEMICAL PROTECTIVE CLOTHING ON COGNITIVE PERFORMANCE
    FINE, BJ
    KOBRICK, JL
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1987, 58 (02): : 149 - 154
  • [6] A computational study on the resistance of protective clothing to chemical compounds
    Ubowska, Agnieszka
    PRZEMYSL CHEMICZNY, 2019, 98 (04): : 586 - 590
  • [7] Effects of metabolic rate and ambient vapour pressure on heat strain in protective clothing
    McLellan, TM
    Pope, JI
    Cain, JB
    Cheung, SS
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1996, 74 (06): : 518 - 527
  • [8] Comparison of conductive heat resistance and radiant heat resistance with thermal protective performance of fire fighter protective clothing
    Stull, JO
    PERFORMANCE OF PROTECTIVE CLOTHING, 6TH VOLUME, 1997, 1273 : 248 - 268
  • [9] Chemical Protective Clothing
    Lovasic, Susan
    CHEMICAL ENGINEERING, 2011, 118 (03) : 51 - 53
  • [10] CHEMICAL PROTECTIVE CLOTHING
    SCHWOPE, AD
    ASTM STANDARDIZATION NEWS, 1983, 11 (07): : 19 - 22