Effect of the Pulsed Electromagnetic Field (PEMF) on Dental Implants Stability: A Randomized Controlled Clinical Trial

被引:17
|
作者
Nayak, Bhukya P. [1 ]
Dolkart, Oleg [2 ]
Satwalekar, Parth [1 ]
Kumar, Yeramala P. [1 ]
Chandrasekar, Anam [1 ]
Fromovich, Ophir [3 ]
Yakobson, Elad [4 ]
Barak, Shlomo [4 ]
Dayube, Ulisses [5 ]
Shibli, Jamil A. [5 ]
机构
[1] Kaloji Narayana Rao Univ Hlth Sci, SVS Inst Dent Sci, Hyderabad 509001, Telangana, India
[2] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sackler Fac Med, Div Orthoped Surg, IL-6423906 Tel Aviv, Israel
[3] Nordau 83, IL-62381 Tel Aviv, Israel
[4] Magdent Ltd, IL-5120109 Bnei Braq, Israel
[5] Univ Guarulhos, Dept Periodontol & Oral Implantol, Dent Res Div, BR-07023040 Guarulhos, SP, Brazil
关键词
pulsed electromagnetic field; osseointegration; implant stability; healing abutment; OSSEOINTEGRATION; IMMEDIATE;
D O I
10.3390/ma13071667
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A pulsed electromagnetic field (PEMF) has been shown to contribute to heightening bone regeneration in a range of clinical areas, including dentistry. Due to the scarcity of studies using PEMF in oral implantology, the present experiment scrutinized the effect of PEMF can lead to improving the stability of the implant. A total of 19 subjects (40 implants in total) were selected to participate in the current study and were randomly allocated to either the PEMF group or control group. Subjects in the PEMF group received an activated miniaturized electromagnetic device (MED) while the control group received a sham healing cup. Implants stability was assessed by resonance frequency analyses (RFA) via implant stability quotient (ISQ) calculations. RFA were recorded as following: immediately after procedure, and then 2, 4, 6, 8 and 12 weeks later. Radiographic analysis was performed at baseline, 6 and 12 weeks after implant placement. Proinflammatory cytokines were evaluated in peri-implant crevicular fluid (PICF). The PEMF group presented higher ISQ mean values when compared to the control group. The primary stability time frame (the first 2 weeks) MED group depicted an increase in stability of 6.8%, compared to a decrease of 7.6% in the control group related to the baseline. An overall stability increase of 13% was found in MED treated group (p = 0.02), in contrast, the overall stability in the control group decreased by 2% (p = 0.008). TNF-alpha concentration during first 4 weeks was lower in the MED treated group. The data strongly suggests that MED generated continuing a PEMF may be considered as a new way to stimulate the stability of the implants at the early healing period.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Randomized, prospective, and controlled clinical trial of pulsed electromagnetic field stimulation for cervical fusion
    Foley, Kevin T.
    Mroz, Thomas E.
    Arnold, Paul M.
    Chandler, Howard C., Jr.
    Dixon, Robert A.
    Girasole, Gerard J.
    Renkens, Kenneth L., Jr.
    Riew, K. Daniel
    Sasso, Rick C.
    Smith, Richard C.
    Tung, Howard
    Wecht, Daniel A.
    Whiting, Donald M.
    SPINE JOURNAL, 2008, 8 (03): : 436 - 442
  • [3] Effect of pulsed electromagnetic field on nonspecific low back pain patients: a randomized controlled trial
    Eishiwi, Ahmed Mohamed
    Hamada, Hamada Ahmed
    Mosaad, Dalia
    Ragab, Ibrahim Mohammed A.
    Koura, Ghada Mohamed
    Alrawaili, Saud Mashi
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2019, 23 (03) : 244 - 249
  • [4] Pulsed electromagnetic field (PEMF) treatment for fracture healing
    Boopalan, P. R. J. V. C.
    Chittaranjan, Samuel B.
    Balamurugan, Ramadass
    Nandakumar, N. S.
    Sabareeswaran, A.
    Mohanty, Mira
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (04): : 423 - 428
  • [5] Randomized controlled clinical trial comparing two dental implants with different neck configurations
    Sanz-Martin, Ignacio
    Sanz-Sanchez, Ignacio
    Noguerol, Fernando
    Cok, Susy
    Ortiz-Vigon, Alberto
    Sanz, Mariano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (03) : 512 - 522
  • [6] Effect of 4 Hz and multifrequency pulsed electromagnetic field (PEMF) on bone fracture healing
    Akdag, Mehmet Zulkuf
    Dasdag, Suleyman
    Gelir, Ali
    Akdag, Mahmut Berat
    Gem, Mehmet
    Baksi, Nazan
    Akpinar, Fuat
    Bicak, Tugcem
    Arica, Enes
    Kutluer, Serdar
    Arican, Rukiye
    Kilinc, Halil
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2024, 38 (01)
  • [7] Effect of Targeted Pulsed Electromagnetic Field Therapy on Canine Postoperative Hemilaminectomy: A Double-Blind, Randomized, Placebo-Controlled Clinical Trial
    Alvarez, Leilani X.
    McCue, John
    Lam, Nathaniel K.
    Askin, Gulce
    Fox, Philip R.
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2019, 55 (02) : 83 - 91
  • [8] Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial
    Parviz Torkzaban
    Shahin Kasraei
    Sara Torabi
    Maryam Farhadian
    Lasers in Medical Science, 2018, 33 : 287 - 293
  • [9] Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial
    Torkzaban, Parviz
    Kasraei, Shahin
    Torabi, Sara
    Farhadian, Maryam
    LASERS IN MEDICAL SCIENCE, 2018, 33 (02) : 287 - 293
  • [10] Effect of Pulsed Electromagnetic Field (PEMF) on Infarct Size and Inflammation After Cerebral Ischemia in Mice
    Juan Carlos Pena-Philippides
    Yirong Yang
    Olga Bragina
    Sean Hagberg
    Edwin Nemoto
    Tamara Roitbak
    Translational Stroke Research, 2014, 5 : 491 - 500