Automated Analysis of Alignment in Long-Leg Radiographs by Using a Fully Automated Support System Based on Artificial Intelligence

被引:38
|
作者
Schock, Justus [1 ,2 ]
Truhn, Daniel [3 ]
Abrar, Daniel B. [1 ]
Merhof, Dorit [2 ]
Conrad, Stefan [4 ]
Post, Manuel [3 ]
Mittelstrass, Felix [3 ]
Kuhl, Christiane [3 ]
Nebelung, Sven [1 ,3 ]
机构
[1] Univ Hosp Dusseldorf, Dept Diagnost & Intervent Radiol, Dusseldorf, Germany
[2] Rhein Westfal TH Aachen, Inst Comp Vis & Imaging, Pauwelsstr 30, D-52072 Aachen, Germany
[3] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[4] Heinrich Heine Univ Dusseldorf, Inst Informat, Fac Math & Nat Sci, Dusseldorf, Germany
关键词
TOTAL KNEE ARTHROPLASTY; LOWER-LIMB; INTRAOBSERVER RELIABILITY; OSTEOARTHRITIS; INTEROBSERVER;
D O I
10.1148/ryai.2020200198
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop and validate a deep learning-based method for automatic quantitative analysis of lower-extremity alignment. Materials and Methods: In this retrospective study, bilateral long-leg radiographs (LLRs) from 255 patients that were obtained between January and September of 2018 were included. For training data (n = 109), a U-Net convolutional neural network was trained to segment the femur and tibia versus manual segmentation. For validation data (n = 40), model parameters were optimized. Following identification of anatomic landmarks, anatomic and mechanical axes were identified and used to quantify alignment through the hipknee-ankle angle (HKAA) and femoral anatomic-mechanical angle (AMA). For testing data (n = 106), algorithm-based angle measurements were compared with reference measurements by two radiologists. Angles and time for 30 random radiographs were compared by using repeated-measures analysis of variance and one-way analysis of variance, whereas correlations were quantified by using Pearson r and intraclass correlation coefficients. Results: Bilateral LLRs of 255 patients (mean age, 26 years 6 23 [standard deviation]; range, 0-88 years; 157 male patients) were included. Mean Sorensen-Dice coefficients for segmentation were 0.97 6 0.09 for the femur and 0.96 6 0.11 for the tibia. Mean HKAAs and AMAs as measured by the readers and the algorithm ranged from 0.05 degrees to 0.11 degrees (P = .5) and from 4.82 degrees to 5.43 degrees (P < .001). Interreader correlation coefficients ranged from 0.918 to 0.995 (r range, P < .001), and agreement was almost perfect (intraclass correlation coefficient range, 0.87-0.99). Automatic analysis was faster than the two radiologists' manual measurements (3 vs 36 vs 35 seconds, P,.001). Conclusion: Fully automated analysis of LLRs yielded accurate results across a wide range of clinical and pathologic indications and is fast enough to enhance and accelerate clinical workflows. Supplemental material is available for this article. (C) RSNA, 2020.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Body height estimation from automated length measurements on standing long leg radiographs using artificial intelligence
    Simon, Sebastian
    Fischer, Barbara
    Rinner, Alexandra
    Hummer, Allan
    Frank, Bernhard J. H.
    Mitterer, Jennyfer A.
    Huber, Stephanie
    Aichmair, Alexander
    Schwarz, Gilbert M.
    Hofstaetter, Jochen G.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Body height estimation from automated length measurements on standing long leg radiographs using artificial intelligence
    Sebastian Simon
    Barbara Fischer
    Alexandra Rinner
    Allan Hummer
    Bernhard J. H. Frank
    Jennyfer A. Mitterer
    Stephanie Huber
    Alexander Aichmair
    Gilbert M. Schwarz
    Jochen G. Hofstaetter
    Scientific Reports, 13
  • [3] Automated analysis of knee joint alignment using detailed angular values in long leg radiographs based on deep learning
    Lee H.S.
    Hwang S.
    Kim S.-H.
    Joon N.B.
    Kim H.
    Hong Y.S.
    Kim S.
    Scientific Reports, 14 (1)
  • [4] EXTERNAL VALIDATION FOR A FULLY AUTOMATED URINE CYTOLOGY SUPPORT ARTIFICIAL INTELLIGENCE SYSTEM
    Kaneko, Masatomo
    Harada, Yuki
    Tsuji, Keisuke
    Paralkar, Divyangi
    Fujihara, Atsuko
    Ueno, Kengo
    Nakanishi, Masaya
    Konishi, Eiichi
    Takamatsu, Tetsuro
    Horiguchi, Go
    Teramukai, Satoshi
    Ito-Ihara, Toshiko
    Abreu, Andre Luis
    Ukimura, Osamu
    JOURNAL OF UROLOGY, 2024, 211 (05): : E628 - E629
  • [5] Fully automated assessment of the knee alignment on long leg radiographs following corrective knee osteotomies in patients with valgus or varus deformities
    Jennyfer A. Mitterer
    Stephanie Huber
    Gilbert M. Schwarz
    Sebastian Simon
    Matthias Pallamar
    Florian Kissler
    Bernhard J. H. Frank
    Jochen G. Hofstaetter
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1029 - 1038
  • [6] Fully automated assessment of the knee alignment on long leg radiographs following corrective knee osteotomies in patients with valgus or varus deformities
    Mitterer, Jennyfer A.
    Huber, Stephanie
    Schwarz, Gilbert M.
    Simon, Sebastian
    Pallamar, Matthias
    Kissler, Florian
    Frank, Bernhard J. H.
    Hofstaetter, Jochen G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (03) : 1029 - 1038
  • [7] Automated Artificial Intelligence-Based Assessment of Lower Limb Alignment Validated on Weight-Bearing Pre- and Postoperative Full-Leg Radiographs
    Erne, Felix
    Grover, Priyanka
    Dreischarf, Marcel
    Reumann, Marie K.
    Saul, Dominik
    Histing, Tina
    Nuessler, Andreas K.
    Springer, Fabian
    Scholl, Carolin
    DIAGNOSTICS, 2022, 12 (11)
  • [8] Comparison of semi and fully automated artificial intelligence driven softwares and manual system for cephalometric analysis
    Zaheer, Rumeesha
    Shafique, Hafiza Zobia
    Khalid, Zahra
    Shahid, Rooma
    Jan, Abdullah
    Zahoor, Tooba
    Nawaz, Ramsha
    ul Hassan, Mehak
    BMC MEDICAL INFORMATICS AND DECISION MAKING, 2024, 24 (01)
  • [9] A FULLY AUTOMATED ARTIFICIAL INTELLIGENCE SUPPORT SYSTEM FOR URINE CYTOLOGY: MULTI-CENTER EXTERNAL VALIDATION STUDY
    Kaneko, Masatomo
    Tsuji, Keisuke
    Harada, Yuki
    Fujihara, Atsuko
    Ueno, Kengo
    Nakanishi, Masaya
    Konishi, Eiichi
    Takamatsu, Tetsuro
    Teramukai, Satoshi
    Ito-Ihara, Toshiko
    Abreu, Andre
    Ukimura, Osamu
    JOURNAL OF UROLOGY, 2023, 209 : E410 - E411
  • [10] An automated diagnostics system for eddy current analysis using artificial intelligence techniques
    Upadhyaya, BR
    Behravesh, MM
    Yan, W
    Henry, G
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1859 - 1862