Experimental Verification for Cable Force Estimation Using Handheld Shooting of Smartphones

被引:31
|
作者
Zhao, Xuefeng [1 ]
Ri, Kwang [1 ,2 ]
Wang, Niannian [1 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Pyongyang Univ Architecture, Sch Civil Engn, Pyongyang 1001, North Korea
基金
中国国家自然科学基金;
关键词
HOUGH TRANSFORM; DISPLACEMENT MEASUREMENT; LINE DETECTION; SYSTEM; IDENTIFICATION; TENSION; SENSORS;
D O I
10.1155/2017/5625396
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, due to the rapid development and popularization of smartphones, the usage of ubiquitous smartphones has attracted growing interest in the field of structural health monitoring (SHM). The portable and rapid cable force measurement for cable-supported structures, such as a cable-stayed bridge and a suspension bridge, has an important and practical significance in the evaluation of initial damage and the recovery of transportation networks. The extraction of dynamic characteristics (natural frequencies) of cable is considered as an essential issue in the cable force estimation. Therefore, in this study, a vision-based approach is proposed for identifying the natural frequencies of cable using handheld shooting of smartphone camera. The boundary of cable is selected as a target to be tracked in the region of interest (ROI) of video image sequence captured by smartphone camera, and the dynamic characteristics of cable are identified according to its dynamic displacement responses in frequency domain. The moving average is adopted to eliminate the noise associated with the shaking of smartphone camera during measurement. A laboratory scale cable model test and a pedestrian cable-stayed bridge test are carried out to evaluate the proposed approach. The results demonstrate the feasibility of using smartphone camera for cable force estimation.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental verification and rapid estimation of uncalibrated cable force via video-based and vibration-based measurements
    Li, Yanhao
    Udi, Ufuoma Joseph
    Yussof, Mustafasanie M.
    Tan, Xing
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (03):
  • [2] Oscillometric blood pressure measurements on smartphones using vibrometric force estimation
    Barry, Colin
    Xuan, Yinan
    Fascetti, Ava
    Moore, Alison
    Wang, Edward Jay
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] Experimental verification of smart cable damping
    Christenson, RE
    Spencer, BF
    Johnson, EA
    JOURNAL OF ENGINEERING MECHANICS, 2006, 132 (03) : 268 - 278
  • [4] Experimental Study for Crowdsourced Ride Quality Index Estimation Using Smartphones
    Medina, Jose R.
    Salim, Ramadan
    Underwood, B. Shane
    Kaloush, Kamil
    JOURNAL OF TRANSPORTATION ENGINEERING PART B-PAVEMENTS, 2020, 146 (04)
  • [5] Experimental Study on Cable Force of Grouted Prestressed Cable
    Chen Y.
    Xia Z.
    Lin Y.
    Zhang F.
    Tiedao Xuebao/Journal of the China Railway Society, 2019, 41 (04): : 151 - 158
  • [6] Tensile force identification in cable-stayed structures: Hybrid system identification algorithm and experimental verification
    Noh, Myung-Hyun
    Hu, Jong Wan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (11) : 4563 - 4572
  • [7] Tensile force identification in cable-stayed structures: Hybrid system identification algorithm and experimental verification
    Myung-Hyun Noh
    Jong Wan Hu
    Journal of Mechanical Science and Technology, 2014, 28 : 4563 - 4572
  • [8] User Verification using Safe Handwritten Passwords on Smartphones
    Kutzner, Tobias
    Ye, Fanyu
    Boenninger, Ingrid
    Travieso, Carlos
    Dutta, Malay Kishore
    Singh, Anushikha
    2015 EIGHTH INTERNATIONAL CONFERENCE ON CONTEMPORARY COMPUTING (IC3), 2015, : 48 - 53
  • [9] Experimental verification of a stay cable delta frame model
    Nimse, Parag S.
    Nims, Douglas K.
    Helmicki, Arthur
    Hunt, Victor J.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-BRIDGE ENGINEERING, 2013, 166 (01) : 5 - 15
  • [10] Development and experimental verification of C-arm camera shooting locator
    Jun Yang
    Lin Yang
    Tae Gyong Jon
    Zejun Fang
    Peng Jin
    Zhenghua Hong
    Fei Ye
    Jiawen Wang
    Scientific Reports, 12 (1)