Simplified model of low energy x-ray backscattering

被引:3
|
作者
Davidovic, DM
Vukanic, J
Arsenovic, D
机构
[1] Vinca Inst Nucl Sci, Belgrade, Yugoslavia
[2] Inst Phys, Belgrade, Yugoslavia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 15期
关键词
D O I
10.1088/0031-9155/48/15/402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reflection of x-rays from a half space is studied within the framework of a model that assumes multiple isotropic scattering of photons without energy loss. An exactly solvable analytical expression for the angular distribution of reflected photons is derived. The range of validity of the model was determined by the Monte Carlo simulation thereby incorporating energy loss and angular dependences. For water as a scatterer, in the energy range from 10 to 60 keV, which is often used in x-ray diagnostics, the two approaches differ by at most 5%. The analytic results, confirmed by the Monte Carlo simulation, show that the angular distribution of reflected photons for energies greater than 30 keV-where multiple scattering events dominate-may be represented by a cosine law, within a few per cent of accuracy.
引用
收藏
页码:N213 / N221
页数:9
相关论文
共 50 条
  • [1] AN X-RAY BACKSCATTERING INSTRUMENT WITH VERY-HIGH-ENERGY RESOLUTION
    DORNER, B
    BURKEL, E
    PEISL, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 450 - 451
  • [2] X-RAY BACKSCATTERING INSTRUMENT WITH VERY HIGH ENERGY RESOLUTION.
    Dorner, B.
    Burkel, E.
    Peisl, J.
    Nuclear instruments and methods in physics research, 1985, A246 (1-3): : 450 - 451
  • [3] STUDY OF X-RAY SURFACE BACKSCATTERING
    NOVIKOV, DV
    KONDRASHKINA, EA
    STEPANOV, SA
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1989, 114 (01): : K7 - K10
  • [4] X-ray diffraction simplified
    Anon
    European Semiconductor, 2000, 22 (11): : 47 - 48
  • [5] A SIMPLIFIED X-RAY SPECTROGRAPH
    DITSMAN, SA
    BOGDANOV, VG
    INDUSTRIAL LABORATORY, 1965, 31 (04): : 618 - &
  • [6] A LOW-ENERGY X-RAY POLARIMETER
    RIEGLER, GR
    GARMIRE, G
    MOORE, W
    STEVENS, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 635 - &
  • [7] ON LOW ENERGY X-RAY ABSORPTION BY NUCLEI
    MCFARLAND, RH
    PHYSICAL REVIEW, 1951, 83 (03): : 666 - 666
  • [8] A Low Energy X-Ray Fluorescence Spectrometer for Elemental Mapping X-Ray Microscopy
    Alberti, R.
    Longoni, A.
    Klatka, T.
    Guazzoni, C.
    Gianoncelli, A.
    Bacescu, D.
    Kaulich, B.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 839 - +
  • [9] Materials Testing with X-Ray Backscattering.
    Kosanetzky, J.
    Harding, G.
    Materialpruefung/Materials Testing, 1987, 29 (7-8): : 217 - 221
  • [10] SIMPLIFIED CALIBRATION PROCEDURE FOR ENERGY-SENSITIVE X-RAY DETECTORS
    SKELTON, EF
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1977, 10 (APR1) : 123 - 123