Structural stability of different reconstruction techniques following total sacrectomy: A biomechanical study

被引:17
|
作者
Cheng, Liming [1 ]
Yu, Yan [1 ]
Zhu, Rui [1 ]
Lv, Haoxuan [1 ]
Jia, Yongwei [1 ]
Zeng, Zhili [1 ]
Chen, Bo [2 ]
Ding, Zuquan [2 ]
机构
[1] Tongji Univ, Sch Med, Tongji Hosp, Dept Spine Surg, Shanghai 200065, Peoples R China
[2] Tongji Univ, Sch Life Sci & Technol, Shanghai 200092, Peoples R China
关键词
Sacrum; Total sacrectomy; Reconstruction; Stability; Biomechanics; PELVIC FIXATION; INTERNAL-FIXATION; FRACTURES; NEOPLASMS; RING;
D O I
10.1016/j.clinbiomech.2011.06.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The biomechanical stability of spino-pelvis structure after varying reconstruction methods following total sacrectomy remains poorly defined. The objective of this study was to compare the structural stability of different reconstruction techniques. Methods: Six fresh human cadavers (L2-pelvis-femora) were used to compare biomechanical stability after reconstruction using four different techniques: (1) sacral rod reconstruction; (2) bilateral fibular flap reconstruction; (3) four-rod reconstruction; and (4) improved compound reconstruction. After total sacrectomy, the construction was carried out using each method once in each cadaver. Structural stiffness was evaluated by linear and angular ranges of motion. L5 relative shift-down displacement, abduction angle on the coronal plane and rotation angle on the sagittal plane, were calculated based on displacement of the identification point under 500 N axial loading. Overall stiffness was estimated using load displacement curve. Findings: Improved compound reconstruction resulted in significantly higher stiffness than all three other techniques. The structural stability following bilateral fibular flap reconstruction was superior to that after sacral rod reconstruction. Four-rod reconstruction achieved worst stability due to the lack of anterior bracing applied in three other methods. Interpretation: Improved compound reconstruction produces optimal structural stability after total sacrectomy. This finding suggests that both anterior bracing and alternation of screw trajectory are important in achieving optimal structural stability. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:977 / 981
页数:5
相关论文
共 50 条
  • [1] Biomechanical Comparison of Spinopelvic Reconstruction Techniques in the Setting of Total Sacrectomy
    Mindea, Stefan A.
    Chinthakunta, Suresh
    Moldavsky, Mark
    Gudipally, Manasa
    Khalil, Saif
    SPINE, 2012, 37 (26) : E1622 - E1627
  • [2] Comprehensive biomechanical analysis of three reconstruction techniques following total sacrectomy: an in vitro human cadaveric model
    Macki, Mohamed
    De la Garza-Ramos, Rafael
    Murgatroyd, Ashley A.
    Mullinix, Kenneth P.
    Sun, Xiaolei
    Cunningham, Bryan W.
    McCutcheon, Brandon A.
    Bydon, Mohamad
    Gokaslan, Ziya L.
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 27 (05) : 570 - 577
  • [3] Biomechanical evaluation of reconstruction after total sacrectomy
    Murakami, Hideki
    Tomita, Katsuro
    Kawahara, Norio
    Sakamoto, Jiro
    Oda, Jyuhati
    Funaki, Katsuyuki
    Critical Reviews in Biomedical Engineering, 1998, 26 (05): : 421 - 422
  • [4] The stability analysis of different reconstruction methods after total sacrectomy
    Yu, Yan
    Cheng, Liming
    Zhu, Rui
    Lv, Haoxuan
    Jia, Yongwei
    Zeng, Zhili
    Yu, Guangrong
    Chen, Bo
    Ding, Zuquan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2745 - +
  • [5] Surgical techniques for spinopelvic reconstruction following total sacrectomy: a systematic review
    S. Samuel Bederman
    Kalpit N. Shah
    Jeffrey M. Hassan
    Bang H. Hoang
    P. Douglas Kiester
    Nitin N. Bhatia
    European Spine Journal, 2014, 23 : 305 - 319
  • [6] Surgical techniques for spinopelvic reconstruction following total sacrectomy: a systematic review
    Bederman, S. Samuel
    Shah, Kalpit N.
    Hassan, Jeffrey M.
    Hoang, Bang H.
    Kiester, P. Douglas
    Bhatia, Nitin N.
    EUROPEAN SPINE JOURNAL, 2014, 23 (02) : 305 - 319
  • [7] Reconstruction of large sacral defects following total sacrectomy
    Miles, WK
    Chang, DW
    Kroll, SS
    Miller, MJ
    Langstein, HN
    Reece, GP
    Evans, GRD
    Robb, GL
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 105 (07) : 2387 - 2394
  • [8] Reconstruction after total sacrectomy using a new instrumentation technique - A biomechanical comparison
    Kawahara, N
    Murakami, H
    Yoshida, A
    Sakamoto, J
    Oda, J
    Tomita, K
    SPINE, 2003, 28 (14) : 1567 - 1572
  • [9] The biomechanical effect of lumbopelvic distance reduction on reconstruction after total sacrectomy: a comparative finite element analysis of four techniques
    Turbucz, Mate
    Pokorni, Agoston Jakab
    Hajnal, Benjamin
    Koch, Kristof
    Szoverfi, Zsolt
    Varga, Peter Pal
    Lazary, Aron
    Eltes, Peter Endre
    SPINE JOURNAL, 2024, 24 (10): : 1981 - 1992
  • [10] Total sacrectomy and reconstruction with structural allografts for neurofibrosarcoma of the sacrum - A case report
    Min, K
    Espinosa, N
    Bode, B
    Exner, GU
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04): : 864 - 869