Inter-Rater and Intra-Rater Reliability of the INSPECT (Interactive Nutrition Specific Physical Exam Competency Tool) Measured in Multi-Site Acute Care Settings

被引:2
|
作者
Zechariah, Sunitha [1 ]
Waller, Jennifer L. [2 ]
Stallings, Judith [1 ]
Gess, Ashley J. [3 ]
Lehman, Leigh [4 ]
机构
[1] Augusta Univ, Coll Allied Hlth Sci, Augusta, GA 30912 USA
[2] Augusta Univ, Med Coll Georgia, Augusta, GA 30912 USA
[3] Augusta Univ, Coll Educ, Augusta, GA 30912 USA
[4] Brenau Univ, Sch Occupat Therapy, Gainesville, GA 30501 USA
关键词
competency; inter-rater reliability; intra-rater reliability; internal consistency; nutrition-focused physical exam; registered dietitian nutritionists; AMERICAN SOCIETY; CONSENSUS; DIETETICS; ACADEMY;
D O I
10.3390/healthcare10020212
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Even as new medical modalities, diagnostics, and technologies are rapidly changing healthcare, providing patients with safe, high-quality care remains the central focus. To provide safe patient care, healthcare providers are obligated to demonstrate and maintain the necessary competence. As more healthcare disciplines move toward a competency-based education model, it is essential to extend the competence verification from the academic educational level to the patient's bedside. The nutrition-focused physical exam (NFPE) is a competency recently adopted by registered dietitian nutritionists (RDNs) for assessing patients' nutritional status. Being a newly acquired skill, validated tools are required to measure NFPE competence during routine clinical practice. The Interactive Nutrition Specific Physical Exam Competency Tool (INSPECT) is a new tool developed specifically to observe and measure RDNs' NFPE competence in clinical settings. The INSPECT was designed and validated for content using expert RDNs' input in the first and second phases of the study. This current study aimed to assess the reliability of the INSPECT through multi-site observations by clinical supervisors evaluating RDNs' NFPE competency during patient assessment. The INSPECT exhibited good inter-rater reliability (ICC = 0.78 for the first assessment and ICC = 0.68 for the second assessment), moderate to strong intra-rater reliability for 37 of 41 items (Spearman rho = 0.54 to 1.0), and excellent internal consistency (Cronbach's alpha = 0.86 for the first assessment and alpha = 0.92 for the second assessment). In total, 10 out of the 11 INSPECT subsets showed good to excellent internal consistency (alpha ranging from 0.70 to 0.98). The results demonstrate that the INSPECT is a reliable tool, is stable over time, and has good agreement and excellent consistency between raters. The INSPECT can be a valuable tool to measure, promote and maintain RDNs' NFPE competence in authentic acute care settings.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [2] Intra-rater and inter-rater reliability of the rapid entire body assessment (REBA) tool
    Schwartz, Adam H.
    Albin, Thomas J.
    Gerberich, Susan G.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2019, 71 : 111 - 116
  • [3] The Scarbase Duo®: Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool
    Fell, Matthew
    Meirte, Jill
    Anthonissen, Mieke
    Maertens, Koen
    Pleat, Jonathon
    Moortgat, Peter
    BURNS, 2016, 42 (02) : 336 - 344
  • [4] Inter-rater and intra-rater reliability of finger goniometry measured from screenshots taken via video consultation
    Johnson, Dane
    Barradas, Rodrigo
    Newington, Lisa
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 459 - 465
  • [5] Intra-Rater and Inter-Rater Reliability of a Medical Record Abstraction Study on Transition of Care after Childhood Cancer
    Gianinazzi, Micol E.
    Rueegg, Corina S.
    Zimmerman, Karin
    Kuehni, Claudia E.
    Michel, Gisela
    PLOS ONE, 2015, 10 (05):
  • [6] Inter-Rater and Intra-Rater Reliability of Quantitative Upper Limb Spasticity Evaluation based on Modified Ashworth Scale Tool
    Puzi, Asmarani Ahmad
    Sidek, Shahrul Naim
    Khairuddin, Ismail Mohd
    Yusof, Hazlina Md.
    Rosly, Hadi Mat
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 126 - 130
  • [7] Assessing the inter-rater and intra-rater reliability of the Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS)
    Miller, Erin
    Brooks, Dina
    O'Brien, Kelly K.
    Beavers, Lindsay
    Stratford, Paul
    Nonoyama, Mika
    Mori, Brenda
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2022, 27 (02)
  • [8] Intra-rater and inter-rater reliability of neutral and target lumbar positioning tests in subjects with and without non-specific lower back pain
    Reddy, Ravi Shankar
    Alahmari, Khalid A.
    Samuel, Paul Silvian
    Tedla, Jaya Shanker
    Kakaraparthi, Venkata Nagaraj
    Rengaramanujam, Kanagaraj
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (02) : 289 - 299
  • [9] Assessment of inter-rater and intra-rater reliability of the Luna EMG robot as a tool for assessing upper limb proprioception in patients with stroke-a prospective observational study
    Leszczak, Justyna
    Pniak, Bogumila
    Druzbicki, Mariusz
    Poswiata, Anna
    Mikulski, Michal
    Roksela, Anna
    Guzik, Agnieszka
    PEERJ, 2024, 12
  • [10] The Intra- and Inter-rater Reliability of an Arm Care Screening Tool in High School Baseball Coaches
    Matsel, Kyle A.
    Brown, Stephanie N.
    Hoch, Matt C.
    Butler, Robert J.
    Westgate, Philip M.
    Malone, Terry R.
    Uhl, Tim L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2021, 16 (06): : 1532 - 1540