Multiple Reference Frame-Based Torque Ripple Reduction in DFIG-DC System

被引:20
|
作者
Xiao, Yan [1 ]
Fahimi, Babak [1 ]
Rotea, Mario A. [2 ]
Li, Yaoyu [2 ]
机构
[1] Univ Texas Dallas, Dept Elect Engn, Richardson, TX 75080 USA
[2] Univ Texas Dallas, Dept Mech Engn, Richardson, TX 75080 USA
关键词
DC link; doubly fed induction generator (DFIG); multiple reference frame; torque ripple mitigation; OPERATION; MINIMIZATION; FREQUENCY;
D O I
10.1109/TPEL.2019.2941957
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a multiple reference frame (MRF)-based approach is proposed to mitigate the torque ripple of the DFIG-dc system. The DFIG-dc system uses a diode bridge rectifier between the stator winding of DFIG and dc link. A reduced-power three-phase pulsewidth modulation converter is connected between the rotor winding of DFIG and dc link. Due to the diode commutation, the stator current and stator flux linkage are distorted with harmonics. To reduce the resulting torque ripple, the rotor currents need to track a pulsating reference signal to compensate the distortion of the stator flux. To improve the current tracking performance, MRF-based estimators are used to calculate the main harmonics in both the command value and actual value of the rotor current. Then, an MRF-based regulator is implemented to achieve an accurate tracking for the harmonics of the rotor current command. Both simulation and experimental results demonstrate the effectiveness of the proposed scheme in reducing the torque ripple. The robustness of the proposed algorithm against deviation of stator frequency is also supported by the simulation and experimental results.
引用
收藏
页码:4971 / 4983
页数:13
相关论文
共 50 条
  • [1] Torque Ripple Reduction in a DFIG-DC System by Resonant Current Controllers
    Iacchetti, Matteo F.
    Marques, Gil D.
    Perini, Roberto
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (08) : 4244 - 4254
  • [2] An Improved Repetitive Control of DFIG-DC System for Torque Ripple Suppression
    Wu, Chao
    Nian, Heng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) : 7634 - 7644
  • [3] Minimization of Torque Ripple in the DFIG-DC System Via Predictive Delay Compensation
    Marques, Gil D.
    Iacchetti, Matteo F.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) : 103 - 113
  • [4] Optimizing DFIG-DC system performance via model predictive control: Torque ripple, DC voltage drop, and THD reduction
    Babaei, Mojtaba
    Marashi, Abbas Nazari
    Liasi, Sahand Ghaseminejad
    ENERGY SCIENCE & ENGINEERING, 2024, 12 (08) : 3550 - 3571
  • [5] Torque ripple and harmonic current suppression of stand-alone DFIG-DC system
    Wang D.
    Zhang F.
    Jing Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (08): : 154 - 163
  • [6] Predictive Torque and Rotor Flux Control of a DFIG-DC System for Torque Ripple Compensation and Loss Minimization
    Cruz, Sergio M. A.
    Marques, Gil D.
    Goncalves, Pedro F. C.
    Iacchetti, Matteo F.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) : 9301 - 9310
  • [7] Mathematical Modeling and Control of Standalone DFIG-DC System in Rotor Flux Reference Frame
    Misra, Himanshu
    Jain, Amit Kumar
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (05) : 3708 - 3719
  • [8] Harmonics reduction in standalone DFIG-DC system by shunt active filter controlled in stator flux reference frame
    Himanshu Misra
    Amit Kumar Jain
    Sādhanā, 2018, 43
  • [9] Harmonics reduction in standalone DFIG-DC system by shunt active filter controlled in stator flux reference frame
    Misra, Himanshu
    Jain, Amit Kumar
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2018, 43 (06):
  • [10] Improved Direct Resonant Control for Suppressing Torque Ripple and Reducing Harmonic Current Losses of DFIG-DC System
    Wu, Chao
    Nian, Heng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (09) : 8739 - 8748