Dynamic assessment of normal aortic valve throughout the cardiac cycle with dual-source computed tomography

被引:2
|
作者
Peng, Li-qing [1 ]
Yang, Zhi-gang [1 ]
Shao, Heng [1 ]
Deng, Wen [1 ]
Yu, Jian-qun [1 ]
Chu, Zhi-gang [1 ]
Chaudhary, Rajesh [1 ]
机构
[1] Sichuan Univ, W China Hosp, Dept Radiol, Chengdu 610041, Sichuan, Peoples R China
关键词
Cardiac valve; Aortic valve; Dual-source computed tomography; Cardiac-gated imaging technique; PLANIMETRY; STENOSIS;
D O I
10.1016/j.ijcard.2011.06.085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:358 / 360
页数:3
相关论文
共 50 条
  • [1] Dynamic assessment of aortic annulus in patients with aortic stenosis throughout cardiac cycle with dual-source computed tomography
    Peng, Li-qing
    Yang, Zhi-gang
    Yu, Jian-qun
    Chu, Zhi-gang
    Deng, Wen
    Shao, Heng
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (02) : 304 - 307
  • [2] Morphological and dynamic features of normal mitral valve evaluated by dual-source computed tomography
    Deng, Wen
    Yang, Zhi-gang
    Peng, Li-qing
    Dong, Zhi-hui
    Chu, Zhi-gang
    Wang, Qi-ling
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (03) : 633 - 636
  • [3] Dual-Source Computed Tomography Assessment of Malfunctioning Mechanical Prosthetic Valve
    Bastarrika, Gorka
    Brabham, William W.
    Brien, Terrence X. O'
    Costello, Philip
    Schoepf, U. Joseph
    ANNALS OF THORACIC SURGERY, 2009, 87 (05): : E50 - E50
  • [4] Subvalvular aortic stenosis: Comprehensive cardiac evaluation with dual-source computed tomography
    Stolzmann, Paul
    Scheffel, Hans
    Bettex, Dominique
    Karlo, Christoph
    Frauenfelder, Thomas
    Pretre, Rene
    Marincek, Borut
    Alkadhi, Hatem
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (01): : 240 - U31
  • [5] Comparison of Aortic Valve Area Measured by Magnetic Resonance Imaging and Dual-Source Computed Tomography
    Bruder, O.
    Jochims, M.
    Hunold, P.
    Jensen, C.
    Forsting, M.
    Sabin, G. V.
    Barkhausen, J.
    Schlosser, T.
    ACTA RADIOLOGICA, 2009, 50 (06) : 645 - 651
  • [6] Heterogeneity of Electron Density in Aortic Valve Calcification of Aortic Stenosis Based on Dual-Source, Dual-Energy Computed Tomography
    Kanisawa, Mitsuru
    Iguchi, Nobuo
    Machida, Haruhiko
    Hagiya, Kenichi
    Higuchi, Ryosuke
    Saji, Mike
    Takamisawa, Itaru
    Nanasato, Mamoru
    Takada, Kaori
    Mizutani, Yoshiyuki
    Isobe, Mitsuaki
    CIRCULATION, 2019, 140
  • [7] Dynamic Myocardial Perfusion Imaging by Dual-Source Computed Tomography
    Parga Filho, Jose Rodrigues
    Lima Moraes Lima, Cintia Souza
    Lima, Felipe Gallego
    Jaques, Tiago da Silveira
    Rodrigues de Avila, Luiz Francisco
    Kalil Filho, Roberto
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 98 (03) : E54 - E58
  • [8] Dynamic dual-source computed tomography imaging for myocardial perfusion
    Li, Allen
    Chan, Y. H.
    Wu, B. E.
    Lam, C. S.
    HONG KONG MEDICAL JOURNAL, 2019, 25 (01)
  • [9] Comparison of Dual-Source Computed Tomography for the Quantification of the Aortic Valve Area in Patients With Aortic Stenosis Versus Transthoracic Echocardiography and Invasive Hemodynamic Assessment
    Ropers, Dieter
    Ropers, Ulrike
    Marwan, Mohammed
    Schepis, Titiano
    Pflederer, Tobias
    Wechsel, Martin
    Klinghammer, Lutz
    Flachskampf, Frank A.
    Daniel, Werner G.
    Achenbach, Stephan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (11): : 1561 - 1567
  • [10] Primary cardiac synovial sarcoma and dual-source cardiac computed tomography findings
    Xu, Yiming
    Xin, Chang
    Huang, Wei
    Shi, Yuzhen
    Bo, Genji
    ACTA CARDIOLOGICA, 2017, 72 (02) : 228 - 229