Influence of Structural Change by Water-tree Degradation on Electrical-tree Inception Voltage

被引:0
|
作者
Yamaguchi, Takanori [1 ]
Kato, Takeyoshi [1 ]
Suzuoki, Yasuo [1 ]
Komori, Fumitaka [2 ]
Tsuji, Taizo [3 ]
Mashima, Hironori [3 ]
机构
[1] Nagoya Univ, Nagoya, Aichi 4648601, Japan
[2] Toba Natl Coll Maritime Technol, Toba, Mie, Japan
[3] Chubu Elect Power Co Inc, Midori Ku, Nagoya, Aichi, Japan
关键词
Water-tree; Electrical-tree; CV power cable;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To improve accuracy of degradation diagnosis for CV power cables, it is important to clarify the mechanism of inception and propagation of electrical-tree from water-tree degradation. In our previous work, ac-electrical-tree inception voltage was measured at 303 K for the samples with water tree formed mainly at 363 K. As a result, the samples with water tree, in spite of the existence of water tree degradation, showed higher ac-electrical-tree inception voltage than those without water tree. This was attributed to electrical field relaxation. To study the effect of change in material structure itself, it is necessary to reduce the field relaxation effect. In the present work, therefore, we used the samples with dried water tree and applied impulse voltages, and discussed the effect of structural change due to water tree degradation. As a result, the impulse-tree inception voltage in the samples with dried water tree was lower than those with water tree but was slightly higher than those without water tree. In the sample with dried water tree, decrease in water molecule density which is considered to restrain the electron may lead to the lower impulse-tree inception voltage. However, the remaining degradation products and structural change may lead to the slightly higher impulse-tree inception voltage than those without water tree. The effect of prolonged ac voltage application prior to impulse voltage was also studied to discuss the effect of water tree degradation on long term deterioration of cable performance.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 50 条
  • [1] Influence of Structural Change by AC Voltage Prestressing on Electrical-tree Inception Voltage of LDPE with Water-tree Degradation
    Kato, T.
    Yamaguchi, T.
    Komori, F.
    Kawahara, T.
    Hidaka, T.
    Suzuoki, Y.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 847 - 850
  • [2] Influence of AC Voltage Prestressing on AC Electrical-tree Inception of Deteriorated LDPE with Dried Water-tree
    Asai, D.
    Kurimoto, M.
    Komori, F.
    Kato, T.
    Funabashi, T.
    Suzuoki, Y.
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 385 - 388
  • [3] Inception of electrical tree from water-tree degradation
    Suzuoki, Y.
    Saito, T.
    Komori, F.
    Uchida, K.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 111 - +
  • [4] Temperature Dependence of Inception of Electrical Tree from Water-tree Degradation
    Hayashi, Y.
    Suzuok, Y.
    Kato, T.
    Komori, F.
    Mashima, H.
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 538 - +
  • [5] Inception of Electrical Tree from Water-Tree Degradation at High Temperature
    Suzuoki, Yasuo
    Hayashi, Yusuke
    Kato, Takeyoshi
    Komori, Fumitaka
    Mashima, Hironori
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 408 - +
  • [6] Inception and propagation of electrical tree from water tree degradation - Effects of water-tree degradation condition and impulse-voltage application
    Saito, T
    Suzuoki, Y
    Komori, F
    Uchida, K
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 714 - 717
  • [7] Inception of electrical tree from water tree degradation - Effect of impulse voltage application and drying of water tree
    Saito, T
    Suzuoki, Y
    Komori, F
    Uchida, K
    2005 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2005, : 540 - 543
  • [8] Inception and propagation of electrical tree from water tree degradation
    Suzuoki, Y
    Saito, T
    Morita, M
    Komori, F
    Wu, K
    Kato, T
    Uchida, K
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 302 - 305
  • [9] Influence of water-tree degradation on electroluminescence spectrum in XLPE
    Watanabe, M.
    Mito, T.
    Muramoto, Y.
    Shimizu, N.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 720 - 723
  • [10] Temperature Dependence of Electrical Tree Inception from Water Tree Degradation
    Hayashi, Yusuke
    Kato, Takeyoshi
    Suzuoki, Yasuo
    Komori, Fumitaka
    Hayashi, Naoki
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 164 - 164