Device-less patent foramen ovale closure by radiofrequency thermal energy

被引:0
|
作者
Walpoth, Nazan B. [1 ]
Habermacher, Kathrin [1 ]
Moarof, Igal [1 ]
Watson, Sandy [1 ]
Wahl, Andreas [1 ]
Windecker, Stephan [1 ]
Schoenenberger, Christa [1 ]
Meier, Bernhard [1 ]
机构
[1] Univ Hosp Bern, Cardiovasc Dept, CH-3010 Bern, Switzerland
关键词
patent foramen ovale; cardiac catheterisation; device-less closure; radiofrequency energy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). Methods: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. Results: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter: 7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. Conclusions: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [1] Patent Foramen Ovale Stroke and Device Closure
    Suradi, Hussam S.
    Hijazi, Ziyad M.
    CARDIOLOGY CLINICS, 2016, 34 (02) : 231 - +
  • [2] Device Closure for Stroke with Patent Foramen Ovale
    Dani, Sourbha
    Singh, Aniruddha
    Trivedi, Nitin
    NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (24): : 2323 - 2323
  • [3] Effectiveness of Amplatzer device for closure of patent foramen ovale
    Ali, Oto
    Kudret, Aytemir
    Ali, Deniz
    Orcun, Ciftci
    Hikmet, Yorgun
    Lale, Tokgozoglu
    Giray, Kabakci
    Nasih, Nazli
    Hilmi, Ozkutlu
    CARDIOVASCULAR DRUGS AND THERAPY, 2007, 21 : S67 - S67
  • [4] Use of a Second Device for the Closure of Patent Foramen Ovale
    Cruz-Gonzalez, Ignacio
    Diaz, Tulio A.
    Inglessis-Azuaje, Ignacio
    Palacios, Igor F.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (11): : 1384 - 1386
  • [5] Patent foramen ovale transcatheter closure device thrombosis
    Nkomo, VT
    Theuma, P
    Maniu, CV
    Chandrasekaran, K
    Miller, FA
    Schaff, HV
    Petty, GW
    Miller, TD
    MAYO CLINIC PROCEEDINGS, 2001, 76 (10) : 1057 - 1061
  • [6] Patent foramen ovale closure using the premere device
    Richartz, B. M.
    HERZ, 2006, 31 (06) : 597 - 597
  • [7] Is patent foramen ovale closure indicated for migraine? Patent Foramen Ovale Closure for Migraine
    Reisman, Mark
    Fuller, Cindy J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) : 468 - 474
  • [8] The Dangerous Patent Foramen Ovale: Device Closure for Stroke Patients with High-Risk Patent Foramen Ovale
    Mojadidi, Mohammad K.
    Zaman, Muhammad O.
    Nietlispach, Fabian
    Tobis, Jonathan M.
    Meier, Bernhard
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (10) : 1366 - 1367
  • [9] Patent Foramen Ovale Closure
    Kussmaul, William G., III
    ANNALS OF INTERNAL MEDICINE, 2018, 168 (05) : 367 - 368
  • [10] Patent foramen ovale closure
    Amin, Zahid
    ANNALS OF PEDIATRIC CARDIOLOGY, 2010, 3 (01) : 35 - 39