Design of sixth-order VCVS active filters using one op-amp

被引:0
|
作者
Pactitis, SA
Theofanous, NG
机构
[1] TEI Athens, Dept Elect, Athens 12243, Greece
[2] Univ Athens, Dept Informat, Athens, Greece
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To realize a sixth-order VCVS active filter, three filters are usually employed in a cascade of suitable second-order blocks. In this paper, we prove that the number of active elements can be reduced to one if we use a sixth-order filter with one operational amplifier (op-amp). Also, a voltage gain K larger than unity (K as a free parameter) decreases the spread element values considerably. A design data table for normalized Butterworth, Chebyshev, and Bessel VCVS active filters and low-pass (LP), high-pass (HP), band-pass (BP), and band-stop (BS) examples are included. With this filter, we have power and space saving, and the table provided and scaling rules enable rapid modeling.
引用
收藏
页码:921 / 927
页数:7