Reliability of the two-unit priority standby system revisited

被引:4
|
作者
Eryilmaz, Serkan [1 ]
Finkelstein, Maxim [2 ,3 ]
机构
[1] Atilim Univ, Dept Ind Engn, TR-06836 Ankara, Turkey
[2] Univ Free State, Bloemfontein, South Africa
[3] ITMO Univ, St Petersburg, Russia
关键词
Matrix-exponential distribution; matrix-geometric distribution; probability generating function; standby systems; Laplace-Stieltjes transform; REPAIRABLE SYSTEMS; AVAILABILITY;
D O I
10.1177/1748006X211051828
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper deals with reliability assessment of the repairable two-unit cold standby system when the first, main unit has the better performance level than the second one. Therefore, after its repair, the main unit is always switched into operation. The new Laplace transform representation for the system's lifetime is obtained for arbitrary operation and repair time distributions of the units. For some particular cases, the Laplace transform of the system is shown to be rational, which enables the use of the matrix-exponential distributions for obtaining relevant reliability indices. The discrete setup of the model is also considered through the corresponding matrix-geometric distributions, which are the discrete analogs of the matrix-exponential distributions.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 50 条
  • [1] Approximations of a two-unit cold standby system's reliability behaviour
    Cheng, K
    Wang, WY
    MICROELECTRONICS AND RELIABILITY, 1996, 36 (05): : 627 - 630
  • [2] Long-run availability of a two-unit standby system subjected to a priority rule
    Vanderperre, EJ
    BULLETIN OF THE BELGIAN MATHEMATICAL SOCIETY-SIMON STEVIN, 2000, 7 (03) : 355 - 364
  • [3] Cost analysis of a two-unit cold standby system subject to degradation, inspection and priority
    Kumar, Jitender
    Kadyan, Mukender Singh
    Malik, Suresh Chander
    Eksploatacja i Niezawodnosc, 2012, 14 (04) : 278 - 283
  • [4] COST ANALYSIS OF A TWO-UNIT COLD STANDBY SYSTEM SUBJECT TO DEGRADATION, INSPECTION AND PRIORITY
    Kumar, Jitender
    Kadyan, Mukender Singh
    Malik, Suresh Chander
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2012, 14 (04): : 278 - 283
  • [5] The reliability analysis of a two-unit cold standby system with failable switch and maintenance equipment
    Meng, Xian-yun
    Yuan, Li
    Yin, Rui-ling
    2006 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND SECURITY, PTS 1 AND 2, PROCEEDINGS, 2006, : 941 - 944
  • [6] Reliability analysis of a two-unit standby system under Marshall-Olkin dependency
    Yaghoubi, Afshin
    Niaki, Seyed Taghi Akhavan
    INTERNATIONAL JOURNAL OF QUALITY & RELIABILITY MANAGEMENT, 2023, 40 (06) : 1587 - 1596
  • [7] Reliability analysis of a two-unit cold standby system with arbitrary distributions and change in units
    Mohamed Salah EL-Sherbeny
    M. A. W. Mahmoud
    Zienab M. Hussien
    Life Cycle Reliability and Safety Engineering, 2020, 9 (3) : 261 - 272
  • [8] Analysis of a two-unit warm standby system subject to degradation
    Mokaddis, G.S.
    Labib, S.W.
    Ahmed, A.M.
    Microelectronics Reliability, 1997, 37 (04): : 641 - 647
  • [9] Two-unit priority standby system subject to random shocks and releigh failure-time distribution
    Gupta, Rakesh
    Chaudhary, Alka
    Microelectronics Reliability, 1992, 32 (12) : 1713 - 1723
  • [10] Analysis of a two-unit warm standby system subject to degradation
    Mokaddis, GS
    Labib, SW
    Ahmed, AM
    MICROELECTRONICS AND RELIABILITY, 1997, 37 (04): : 641 - 647