Soft tissue-based registration of intraoral scan with cone beam computed tomography scan

被引:8
|
作者
Deferm, J. T. [1 ]
Nijsink, J. [2 ]
Baan, F. [3 ]
Verhamme, L. [3 ]
Meijer, G. [1 ,4 ]
Maal, T. [3 ]
机构
[1] Radboud Univ Nijmegen, Dept Oral & Maxillofacial Surg, Med Ctr, Geert Grootepl 10, NL-6525 GA Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol Ad Nucl Med, 3D Lab, Med Ctr, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Dept Oral & Maxillofacial Surg, 3D Lab, Med Ctr, Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Dept Implantol & Periodontol, Med Ctr, Nijmegen, Netherlands
关键词
three-dimensional imaging; cone-beam computed tomography; computer-assisted image processing; edentulous jaw; pre-prosthetic oral surgical procedures; maxilla; mouth; GUIDED IMPLANT-SURGERY;
D O I
10.1016/j.ijom.2021.04.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate a novel soft tissue-based method to register an intraoral scan (IOS) with a cone beam computed tomography (CBCT) scan. IOS and CBCT data were obtained from eight dentate patients (mean age 21 +/- 2 years; three male, five female) and 14 fully edentulous patients (mean age 56 +/- 9 years; eight male, six female). An algorithm was developed to create a soft tissue model of the CBCT scan, which allowed a soft tissue-based registration to be performed with the IOS. First, validation was performed on dentate jaws with registration of the palatal mucosal surface and accuracy evaluation at the level of the teeth. Second, fully edentulous jaws were registered using both the palatal and alveolar crest mucosal surfaces. Distance maps were created to measure the method accuracy. The mean registration error was 0.49 +/- 0.26 mm for the dentate jaws. Registration of the fully edentulous jaws had a mean error of 0.16 +/- 0.08 mm at the palate and 0.16 +/- 0.05 mm at the alveolar crest. In conclusion, the high accuracy of this registration method may allow the digital workflow to be optimized when no teeth are available to perform a regular registration procedure.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [1] Validation of automated registration of intraoral scan onto Cone Beam Computed Tomography for an efficient digital dental workflow
    Preda, Flavia
    Nogueira-Reis, Fernanda
    Stanciu, Eugen Marius
    Smolders, Andreas
    Jacobs, Reinhilde
    Shaheen, Eman
    JOURNAL OF DENTISTRY, 2024, 149
  • [2] The influence of metal artifact reduction on the trueness of registration of a cone-beam computed tomography scan with an intraoral scan in the presence of severe restoration artifact
    Biun, John
    Dudhia, Raahib
    Arora, Himanshu
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 700 - 705
  • [3] Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan
    Deferm, Julie Tilly
    Baan, Frank
    Nijsink, Johan
    Verhamme, Luc
    Maal, Thomas
    Meijer, Gert
    IMAGING SCIENCE IN DENTISTRY, 2023, 53 (01) : 21 - 26
  • [4] The in-vitro accuracy of fiducial marker-based versus markerless registration of an intraoral scan with a cone-beam computed tomography scan in the presence of restoration artifact
    Biun, John
    Dudhia, Raahib
    Arora, Himanshu
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (11) : 1257 - 1266
  • [5] Positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan using surface scan registration
    Jamjoom, Faris Z.
    Kim, Do-Gyoon
    McGlumphy, Edwin A.
    Lee, Damian J.
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 367 - 374
  • [6] Novel Procedure for Automatic Registration between Cone-Beam Computed Tomography and Intraoral Scan Data Supported with 3D Segmentation
    Kim, Yoon-Ji
    Ahn, Jang-Hoon
    Lim, Hyun-Kyo
    Nguyen, Thong Phi
    Jha, Nayansi
    Kim, Ami
    Yoon, Jonghun
    BIOENGINEERING-BASEL, 2023, 10 (11):
  • [7] Evaluation of the accuracy of cone-beam computed tomography for measuring intraoral soft tissue thickness
    Wang, Xue-Yu
    Shi, Yan-Wei
    Zhou, Song
    Chen, Yu-Hui
    Yan, Shu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (01): : 37 - 44
  • [8] Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: An in vitro study
    Jamjoom, Faris Z.
    Yilmaz, Burak
    Johnston, William M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (08) : 826 - 832
  • [9] Tetrahedron-based orthogonal simultaneous scan for cone-beam computed tomography
    Ye, Ivan B.
    Wang, Ge
    OPTICAL ENGINEERING, 2012, 51 (08)
  • [10] Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique
    Lee, Soo Young
    Kim, Heechul
    Lee, Doyun
    Park, Chan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 212 - 215