A prospective randomized trial comparing contrast-enhanced targeted versus systematic ultrasound guided biopsies: Impact on prostate cancer detection

被引:63
|
作者
Mitterberger, Michael
Horninger, Wolfgang
Pelzer, Alexandre
Strasser, Hannes
Bartsch, Georg
Moser, Patrizia
Halpern, Ethan J.
Gradl, Johann
Aigner, Friedrich
Pallwein, Leo
Frauscher, Ferdinand
机构
[1] Med Univ Innsbruck, Dept Urol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Radiat 2, Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Pathol, Innsbruck, Austria
[4] Thomas Jefferson Univ, Div Diagnost Ultrasound, Philadelphia, PA USA
来源
PROSTATE | 2007年 / 67卷 / 14期
关键词
prostate cancer; ultrasound; contrast-enhanced ultrasound; prostate biopsy;
D O I
10.1002/pros.20639
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: We performed a prospective randomized trial comparing 5 contrast-enhanced color Doppler (CECD) ultrasound (US) targeted biopsy cores to 10 gray-scale US guided systematic biopsy (SB) cores to determine the impact on the cancer detection rate. METHODS:. We prospectively randomized 100 prostate specific antigen (PSA) screening volunteers with an elevated PSA (>= 1.25 ng/ml and free-to-total PSA < 18%) to undergo contrast-enhanced targeted or SB. Contrast-enhanced targeted biopsies with a limited number of five cores were performed into hypervascular areas of the peripheral zone (PZ) during administration of the US contrast agent SonoVue (R) (Bracco, Italy). A subjective grading of the vascularity from 0 to 3 was used: grade 0, no color signal; 1, low density; 2, medium density; and 3, high density of color signals. Ten SBs were obtained in a standard spatial distribution. Cancer detection rates were compared in the groups. RESULTS: Cancer was detected in 16/50 subjects (32%) by targeted biopsy, and in 13/50 patients (26%) with SB. The cancer detection rate was significantly better for the targeted approach (P < 0.04, McNemar). The detection rate for targeted biopsy cores (15.6% or 39/250 cores) was significantly better than for SB cores (6.8% or 34/500 cores, P < 0.001, McNemar). CONCLUSIONS:. CECD targeted biopsy detected more cancers than SB with a reduced number of biopsy cores.
引用
收藏
页码:1537 / 1542
页数:6
相关论文
共 50 条
  • [2] A prospective randomized trial comparing contrast-enhanced targeted versus systematic ultrasound guided biopsies:: Impact on prostate cancer detection
    Frauscher, F
    Pallwein, L
    Koppelstätter, F
    Berger, AP
    Leonhartsberger, N
    Klauser, A
    Bartsch, GC
    Halpern, EJ
    JOURNAL OF UROLOGY, 2005, 173 (04): : 464 - 464
  • [3] Contrast-enhanced versus systematic transrectal ultrasound-guided prostate cancer detection: An overview of techniques and a systematic review
    Heijmink, Stijn W. T. P. J.
    Barentsz, Jelle O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 63 (03) : 310 - 316
  • [4] Comparative efficiency of contrast-enhanced colour Doppler ultrasound targeted versus systematic biopsy for prostate cancer detection
    Michael Josef Mitterberger
    Friedrich Aigner
    Wolfgang Horninger
    Hanno Ulmer
    Silvio Cavuto
    Ethan J. Halpern
    Ferdinand Frauscher
    European Radiology, 2010, 20 : 2791 - 2796
  • [5] Comparative efficiency of contrast-enhanced colour Doppler ultrasound targeted versus systematic biopsy for prostate cancer detection
    Mitterberger, Michael Josef
    Aigner, Friedrich
    Horninger, Wolfgang
    Ulmer, Hanno
    Cavuto, Silvio
    Halpern, Ethan J.
    Frauscher, Ferdinand
    EUROPEAN RADIOLOGY, 2010, 20 (12) : 2791 - 2796
  • [6] Contrast-enhanced ultrasound targeted versus conventional ultrasound guided systematic prostate biopsy for the accurate diagnosis of prostate cancer: A meta-analysis
    Zhang, Ming
    Meng, Qingsong
    Feng, Lulu
    Wang, Dongbin
    Qu, Changbao
    Tian, Hui
    Jia, Jianghua
    Gao, Qinglu
    Wang, Xin
    MEDICINE, 2022, 101 (51)
  • [7] Comparison of contrast-enhanced ultrasound targeted biopsies versus standard systematic biopsies for prostate cancer correction in different PSA value groups in rural China
    Lu, Dian Yuan
    Liu, Lan
    Shen, Li
    Cai, Jian Rong
    Xu, Li
    Xiang, Li Hua
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 77 (03) : 295 - 301
  • [8] PROSTATE CANCER DETECTION USING POWER DOPPLER CONTRAST-ENHANCED ULTRASONOGRAPHY AND ELASTOGRAPHY FOR TARGETED BIOPSIES
    Budau, M.
    Jinga, V
    Braticevici, B.
    Ambert, V
    Radavoi, G. D.
    Calin, C.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 271 - 271
  • [9] A Deep Learning Approach for Targeted Contrast-Enhanced Ultrasound Based Prostate Cancer Detection
    Feng, Yujie
    Yang, Fan
    Zhou, Xichuan
    Guo, Yanli
    Tang, Fang
    Ren, Fengbo
    Guo, Jishun
    Ji, Shuiwang
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2019, 16 (06) : 1794 - 1801
  • [10] Comparison of contrast-enhanced ultrasound targeted biopsy versus standard systematic biopsy for clinically significant prostate cancer detection: results of a prospective cohort study with 1024 patients
    Zhu Yunkai
    Chen Yaqing
    Jiang Jun
    Qi Tingyue
    Liu Weiyong
    Qu Yuehong
    Guan Wenbin
    Wang Lifeng
    Qi Jun
    WORLD JOURNAL OF UROLOGY, 2019, 37 (05) : 805 - 811