摘要
The objective of this study was to present the design of a prototype rear impact crash test dummy, representing a 50th percentile female, and compare its performance to volunteer response data. The intention was to develop a first crude prototype as a first step toward a future biofidelic 50th percentile female rear impact dummy. The current rear impact crash test dummy, BioRID II, represents a 50th percentile male, which may limit the assessment and development of whiplash protection systems with regard to female occupants. Introduction of this new dummy size will facilitate evaluation of seat and head restraint (HR) responses in both the average sized female and male in rear impacts. A 50th percentile female rear impact prototype dummy, the BioRID P50F, was developed from modified body segments originating from the BioRID II. The mass and rough dimensions of the BioRID P50F is representative of a 50th percentile female. The prototype dummy was evaluated against low severity rear impact sled tests comprising six female volunteers closely resembling a 50th percentile female with regard to stature and mass. The head/neck response of the BioRID P50F prototype resembled the female volunteer response corridors. The stiffness of the thoracic and lumbar spinal joints remained the same as the average sized male BioRID II, and therefore likely stiffer than joints of an average female. Consequently, the peak rearward angular displacement of the head and T1, and the rearward displacement of the T1, were lesser for the BioRID P50F in comparison to the female volunteers. The biofidelity of the BioRID P50F prototype thus has some limitations. Based on a seat response comparison between the BioRID P50F and the BioRID II, it can be concluded that the male BioRID II is an insufficient representation of the average female in the assessment of the dynamic seat response and effectiveness of whiplash protection systems.
引用
收藏
页数:9
相关论文
共 2 条
  • [1] Anthropometric Specifications, Development, and Evaluation of EvaRID-A 50th Percentile Female Rear Impact Finite Element Dummy Model
    Carlsson, Anna
    Chang, Fred
    Lemmen, Paul
    Kullgren, Anders
    Schmitt, Kai-Uwe
    Linder, Astrid
    Svensson, Mats Y.
    TRAFFIC INJURY PREVENTION, 2014, 15 (08) : 855 - 865
  • [2] DEVELOPMENT OF A NEW FINITE ELEMENT MODEL IN ABAQUS FOR THE WORLDSID 50TH PERCENTILE MALE SIDE IMPACT DUMMY
    Scarlat, George
    Sankar, Sridhar
    Oancea, Victor
    Grimes, Bill
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 9, 2012, : 57 - 68