Intra-session repeatability of anterior chamber depth across the chamber width using Pentacam Scheimpflug imaging in healthy subjects

被引:3
|
作者
Phu, Jack [1 ,2 ]
Tong, Janelle [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Kensington, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Kensington, NSW, Australia
关键词
angle closure; angle closure disease; glaucoma; narrow angles; Pentacam; Scheimpflug imaging; OPTICAL COHERENCE TOMOGRAPHY; PATTERN-RECOGNITION ANALYSIS; ANGLE-CLOSURE; CORNEAL; AGREEMENT; VALIDITY; AGE;
D O I
10.1111/opo.12880
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatability of Pentacam Scheimpflug photography for measuring the ACD across the chamber width in healthy subjects and thus inform expected limits of normality. Methods Pentacam Scheimpflug photography was used to obtain ACD measurements at 57 points across the central 8mm of the chamber width from one randomly selected eye of 130 healthy (normal vision and no ocular diseases, except age-normal cataracts) subjects (median age 58.0 years, interquartile range 46.3-63.0 years; 48 males, 82 females). Intra-session ACD measurements were compared. Univariate and multivariate linear regression was performed to identify categorical and continuous variables demonstrating a significant relationship with ACD and its repeatability. Results Bland-Altman analyses showed no directional or depth-dependent bias in the difference between the first and second tests (mean bias -0.003 mm, 95% limits of agreement -0.115 to +0.109 mm). Multivariate analysis found gender to be a significant factor (p < 0.0001), but not age (p = 0.69) nor ethnicity (p = 0.65), although the model fit was poor (R-2 = 0.004). There were no regional differences in repeatability measures found in males, but six locations in the superior aspect in females were found to be significantly different in their repeatability characteristics. Tolerance limits used to calculate the number of step sizes between 60-year-old age groups found 8.1-11.5 steps for females, and 7.5-9.2 steps for males. Conclusions Scheimpflug imaging using the Pentacam has excellent intra-session repeatability. Only gender appeared to affect repeatability characteristics, manifesting with a greater number of meaningful steps of change between two extremes of age range in females compared to males, which provides guidance for identifying clinically significant and measurable change between tests.
引用
收藏
页码:1273 / 1284
页数:12
相关论文
共 47 条
  • [1] Anterior chamber depth in normal subjects by rotating scheimpflug imaging
    Feng, Matthew T.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Grewal, Satinder P. S.
    Yan, Wang
    Shaheen, Mohamed S.
    McGhee, Charles
    Maeda, Naoyuki
    Neuhann, Tobias H.
    Dick, H. Burkhard
    Alageel, Saleh A.
    Steinmueller, Andreas
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2011, 25 (03) : 255 - 259
  • [2] Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan
    Lackner, Birgit
    Schmidinger, Gerald
    Skorpik, Christian
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) : 858 - 861
  • [3] Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement
    Wang, Qinmei
    Ding, Xixia
    Savini, Giacomo
    Chen, Hao
    Feng, Yifan
    Pan, Chao
    Hua, Yanjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 178 - 185
  • [4] Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    Rabsilber, TM
    Khoramnia, R
    Auffarth, GU
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 456 - 459
  • [5] The Alterations of the Anterior Chamber Parameters Measured with Pentacam with Age in Healthy Subjects
    Emre, Sinan
    Koc, Bekir
    Doganay, Selim
    Yologlu, Saim
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (06): : 452 - 458
  • [6] Alteration of anterior chamber in 81 glaucomatous eyes using Pentacam Scheimpflug system
    Zou, Xuan
    Duan, Xuan-Chu
    Zhong, Qian
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2010, 3 (04) : 349 - 351
  • [7] Anterior chamber depth measurement using Pentacam and Biograph in children
    Hashemi, Hassan
    Heydarian, Samira
    Khabazkhoob, Mehdi
    Emamian, Mohammad Hassan
    Yekta, Abbasali
    Fotouhi, Akbar
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (06) : 582 - 586
  • [8] Intra-session repeatability of iridocorneal angle measurements in normal subjects and glaucoma patients using Scheimpflug-Placido disc topographer
    Mansoori, Tarannum
    Balakrishna, Nagalla
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (05) : 1849 - 1851
  • [9] Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes
    Ruiz-Belda, Clara
    Pinero, David P.
    Ruiz-Fortes, Pedro
    Soto-Negro, Roberto
    Moya, Myriam
    Perez-Cambrodi, Rafael J.
    Artola, Alberto
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (01) : 169 - 175
  • [10] Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes
    Clara Ruiz-Belda
    David P. Piñero
    Pedro Ruiz-Fortes
    Roberto Soto-Negro
    Myriam Moya
    Rafael J Pérez-Cambrodí
    Alberto Artola
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 169 - 175