Registration of low molecular weight environmental toxins with total internal reflection ellipsometry

被引:5
|
作者
Nabok, AV [1 ]
Tsargorodskaya, A [1 ]
Holloway, A [1 ]
Starodub, NF [1 ]
Demchenko, A [1 ]
Gojster, O [1 ]
机构
[1] Sheffield Hallam Univ, Fac ACES, Mat Engn Res Inst, Sheffield S1 1WB, S Yorkshire, England
关键词
T2; mycotoxin; simazine; atrazine; immune assay; spectroscopic ellipsometry; total internal reflection; SPR; QCM impedance spectroscopy;
D O I
10.1109/ICSENS.2004.1426392
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A very sensitive optical method of Total Internal Reflection Ellipsometry (TIRE) in conjunction with immune assay approach were exploited for the registration of low molecular weight environmental toxins, such as simazine, atrazine and T2 mycotoxin in a wide range of concentrations down to 0.1 ng/ml. QCM Impedance measurements provided additional information on the mechanism of T2 binding.
引用
收藏
页码:1195 / 1198
页数:4
相关论文
共 50 条
  • [1] Total internal reflection ellipsometry and SPR detection of low molecular weight environmental toxins
    Nabok, AV
    Tsargorodskaya, A
    Hassan, AK
    Starodub, NF
    APPLIED SURFACE SCIENCE, 2005, 246 (04) : 381 - 386
  • [2] Total internal reflection ellipsometry of periodic structures
    Pistora, J
    Vlcek, J
    Hlubina, P
    Foldyna, M
    Zivotsky, O
    PHOTONICS, DEVICES, AND SYSTEMS III, 2006, 6180
  • [3] Total internal reflection ellipsometry: principles and applications
    Arwin, H
    Poksinski, M
    Johansen, K
    APPLIED OPTICS, 2004, 43 (15) : 3028 - 3036
  • [4] Potential Modulation on Total Internal Reflection Ellipsometry
    Liu, Wei
    Niu, Yu
    Viana, A. S.
    Correia, Jorge P.
    Jin, Gang
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3211 - 3217
  • [5] Biosensor with total internal reflection imaging ellipsometry
    Chen, Y-Y.
    Wang, Z-H.
    Meng, Y-H.
    Jin, G.
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2007, 4 (1-2) : 171 - 178
  • [6] Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods
    Nabok, A. V.
    Tsargorodskaya, A.
    Holloway, A.
    Starodub, N. F.
    Gojster, O.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 885 - 890
  • [7] Detection of low molecular weight toxins using an optical phase method of ellipsometry
    Nabok, A.
    Tsargorodskaya, A.
    Mustafa, M. K.
    Szekacs, I.
    Starodub, N. F.
    Szekacs, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 154 (02): : 232 - 237
  • [8] Study of optical anisotropy in thin molecular layers by total internal reflection ellipsometry
    Balevicius, Z.
    Makaraviciute, A.
    Babonas, G. -J.
    Tumenas, S.
    Bukauskas, V.
    Ramanaviciene, A.
    Ramanavicius, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 119 - 124
  • [9] Monolayer film analysis by total internal reflection ellipsometry
    Vaicikauskas, V.
    Balevicius, Z.
    LITHUANIAN JOURNAL OF PHYSICS, 2007, 47 (01): : 81 - 85
  • [10] Copper corrosion monitoring with total internal reflection ellipsometry
    Poksinski, M
    Dzuho, H
    Arwin, H
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (11) : B536 - B539