Total airborne mold particle sampling: Evaluation of sample collection, preparation and counting procedures, and collection devices

被引:9
|
作者
Godish, Diana [2 ]
Godish, Thad [1 ]
机构
[1] Ball State Univ, Dept Nat Resources & Environm Management, Muncie, IN 47306 USA
[2] Ball State Univ, Dept Physiol & Hlth Sci, Muncie, IN 47306 USA
关键词
mold; mold counts; mold samplers; mold spores/particles; total airborne mold;
D O I
10.1080/15459620701828310
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 28 条
  • [1] Technical note: Optimization of the preparation of cascade impactors collection substrates for airborne metallic ultrafine particle sampling
    Gaudel, Naima
    Bau, Sebastien
    Matera, Virginie
    JOURNAL OF AEROSOL SCIENCE, 2024, 181
  • [2] Sample collection and preparation for analysis of airborne particulate matter by total reflection X-ray fluorescence spectrometry
    Schmeling, M
    Klockow, D
    ANALYTICA CHIMICA ACTA, 1997, 346 (01) : 121 - 126
  • [3] Drug testing in oral fluid - Evaluation of sample collection devices
    Langel, Kaarina
    Engblom, Charlotta
    Pehrsson, Anna
    Gunnar, Teemu
    Ariniemi, Kari
    Lillsunde, Pirjo
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (06) : 393 - 401
  • [4] The first harmonised total diet study in Portugal: Planning, sample collection and sample preparation
    Vasco, Elsa
    Dias, M. Grata
    Oliveira, Luisa
    FOOD CHEMISTRY, 2021, 363
  • [5] Portable automated handheld sample collection-preparation instrument for airborne volatile substances
    Bimbiraite-Surviliene, Kristina
    Drevinskas, Tomas
    Maruska, Audrius
    Kornysova, Olga
    Gorbatsova, Jelena
    Ihara, Hirotaka
    Kaljurand, Mihkel
    MICROCHEMICAL JOURNAL, 2020, 159
  • [6] Revisiting herbage sample collection and preparation procedures to minimise risks of trace element contamination
    Dahlin, A. Sigrun
    Edwards, Anthony C.
    Lindstrom, Bodil E. M.
    Ramezanian, Atefeh
    Shand, Charles A.
    Walker, Robin L.
    Watson, Christine A.
    Oborn, Ingrid
    EUROPEAN JOURNAL OF AGRONOMY, 2012, 43 : 33 - 39
  • [7] Evaluation of salt particle collection devices for coastal metal storage facilities with natural ventilation
    National Atomic Research Institute, No. 1000 Wenhua Road Jiaan Village Longtan Township, Taoyuan City
    325207, Taiwan
    J. Phys. Conf. Ser., 1
  • [8] Review of sampling, sample and data collection procedures in nursing research - An example of research on ethical climate as perceived by nurses
    Suhonen, Riitta
    Stolt, Minna
    Katajisto, Jouko
    Leino-Kilpi, Helena
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2015, 29 (04) : 843 - 858
  • [9] Identification of optimal sample collection devices and sampling locations for the detection of environmental viral contamination in wire poultry cages
    Mo, Jongseo
    Spackman, Erica
    Stephens, Christopher B.
    TRANSBOUNDARY AND EMERGING DISEASES, 2021, 68 (02) : 598 - 604
  • [10] COXSACKIE VIRUSES FROM SEWAGE - METHODOLOGY INCLUDING AN EVALUATION OF THE GRAB SAMPLE AND GAUZE PAD COLLECTION PROCEDURES
    MELNICK, JL
    EMMONS, J
    OPTON, EM
    COFFEY, JH
    AMERICAN JOURNAL OF HYGIENE, 1954, 59 (02): : 185 - 195