Surface plasmon resonance imaging biosensor based on silicon photodiode array

被引:0
|
作者
Yin, Shaoyun [1 ]
Sun, Xiuhui [1 ]
Deng, Qiling [1 ]
Xia, Liangpin [1 ]
Du, Chunlei [1 ]
机构
[1] Chinese Acad Sci, Inst Opt & Elect, State Key Lab Opt Technol Microfabricat, Chengdu 610209, Sichuan Prov, Peoples R China
关键词
SPRI; Biosensor; Photodiode array;
D O I
10.1117/12.869483
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The detection limit of surface plasmon resonance imaging (SPRI) biosensor is constrained in part by the SPR biochip and in part by the resolution of the optical intensity of detecting instruments. In this paper, silicon photodiode is proposed as the optical intensity detecting element instead of the traditionally used charge coupled device (CCD), combining with high resolution analog/digital converter, this method can efficiently reduce the cost and increase the sensitivity of the SPRI system while keeping its virtue of multiple channels real time detecting. Based on this method, An SPRI experimental system with two channels is designed and the optical intensity of each channel is detected by a photodiode. By carrying out testing experiments using sucrose solution with different concentrations (corresponding to different refractive index), the system sensitivity of 10(-6) refractive index unit (RIU) is obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A surface plasmon resonance array biosensor based on spectroscopic imaging
    O'Brien, MJ
    Pérez-Luna, VH
    Brueck, SRJ
    López, GP
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (1-2): : 97 - 108
  • [2] An Array Detection Biosensor Based on Surface Plasmon Resonance Interferometric Imaging
    Wang, Daqian
    Deng, Yan
    Ding, Xiang
    Ding, Lili
    Zhang, Enyao
    Yu, Xinglong
    SENSOR LETTERS, 2011, 9 (02) : 728 - 731
  • [3] Colorimetric surface plasmon resonance imaging (SPRI) biosensor array based on polarization orientation
    Wong, Chi Lok
    Chen, George Chung Kit
    Li, Xiaochao
    Ng, Beng Koon
    Shum, Ping
    Chen, Peng
    Lin, Zhiping
    Lin, Chinlon
    Olivo, Malini
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 545 - 552
  • [4] A surface plasmon resonance biosensor based on gold nanoparticle array
    Du, Yuchan
    Shi, Lina
    Hong, Meihua
    Li, Hailiang
    Li, Dongmei
    Liu, Ming
    OPTICS COMMUNICATIONS, 2013, 298 : 232 - 236
  • [5] SURFACE PLASMON RESONANCE IMAGING BIOSENSOR BASED ON GRAPHENE MULTILAYER
    Maharana, Pradeep Kumar
    Srivastava, Triranjita
    Jha, Rajan
    2012 INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS (PHOTONICS), 2012,
  • [6] Biosensor arrays based on surface plasmon resonance phase imaging
    Wong, C. L.
    Ho, H. P.
    Suen, Y. K.
    Chow, Winnie W. Y.
    Wu, S. Y.
    Li, W. J.
    Kong, S. K.
    Lin, Chinlon
    PROCEEDINGS OF INTERNATIONAL SYMPOSIUM ON BIOPHOTONICS, NANOPHOTONICS AND METAMATERIALS, 2006, : 91 - +
  • [7] Polarimetric surface plasmon resonance imaging biosensor
    Duval, Aurelien
    Laisne, Aude
    Pompon, Denis
    Held, Sylvain
    Bellemain, Alain
    Moreau, Julien
    Canva, Michael
    OPTICS LETTERS, 2009, 34 (23) : 3634 - 3636
  • [8] Polarimetric surface plasmon resonance imaging biosensor
    Duval, A.
    Bardin, F.
    Moreau, J.
    Aide, A.
    Bellemain, A.
    Canva, M.
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III, 2007, 6631
  • [9] Surface plasmon resonance phase imaging for array based biosensing
    Halpern, Aaron
    Chen, Yulin
    Kim, Donghyun
    Corn, Robert
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [10] Scanning surface plasmon resonance biosensor for array sample detection
    Qi, Pan
    Li, Ying
    Feng, Ming-Chuang
    Zhong, Jin-Gang
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2012, 20 (11): : 2365 - 2372