Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans

被引:140
|
作者
Gribel, Bruno Frazao [1 ]
Gribel, Marcos Nadler
Frazao, Diogo Campos
McNamara, James A., Jr. [2 ,3 ,4 ]
Manzi, Flavio Ricardo [5 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Orthodont, BR-31340580 Belo Horizonte, MG, Brazil
[2] Univ Michigan, Dept Orthodont & Pediat Dent, Sch Dent, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Human Growth & Dev, Ann Arbor, MI 48109 USA
[5] Pontificia Univ Catolica Minas Gerais, Dept Radiol, Sch Dent, BR-31340580 Belo Horizonte, MG, Brazil
关键词
CBCT; Accuracy; Cephalometry; 3D; Quantitative; Diagnosis; BEAM COMPUTED-TOMOGRAPHY; LANDMARK IDENTIFICATION; FACIAL ASYMMETRY; 3D-CT EVALUATION; IN-VIVO; IMAGES; CT;
D O I
10.2319/032210-166.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the accuracy of craniometric measurements made on lateral cephalograms and on cone beam computed tomography (CBCT) images. Materials and Methods: Ten fiducial markers were placed on known craniometric landmarks of 25 dry skulls with stable occlusions. CBCT scans and conventional lateral headfilms subsequently were taken of each skull. Direct craniometric measurements were compared with CBCT measurements and with cephalometric measurements using repeated measures analysis of variance (ANOVA). All measurements were repeated within a 1-month interval, and intraclass correlations were calculated. Results: No statistically significant difference was noted between CBCT measurements and direct craniometric measurements (mean difference, 0.1 mm). All cephalometric measurements were significantly different statistically from direct craniometric measurements (mean difference, 5 mm). Significant variations among measurements were noted. Some measurements were larger on the lateral cephalogram and some were smaller, but a pattern could be observed: midsagittal measurements were enlarged uniformly, and Co-Gn was changed only slightly; Co-A was always smaller. Conclusion: CBCT craniometric measurements are accurate to a subvoxel size and potentially can be used as a quantitative orthodontic diagnostic tool. Two-dimensional cephalometric norms cannot be readily used for three-dimensional measurements because of differences in measurement accuracy between the two exams. (Angle Orthod. 2011;81:26-35.)
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [1] A comparison between 2D and 3D cephalometry on CBCT scans of human skulls
    van Vlijmen, O. J. C.
    Maal, T.
    Berge, S. J.
    Bronkhorst, E. M.
    Katsaros, C.
    Kuijpers-Jagtman, A. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (02) : 156 - 160
  • [2] High Reliability for Semiautomated 3D Measurements Based on Weightbearing CT Scans
    Kvarda, Peter
    Krahenbuhl, Nicola
    Susdorf, Roman
    Burssens, Arne
    Ruiz, Roxa
    Barg, Alexej
    Hintermann, Beat
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (01) : 91 - 95
  • [3] The accuracy and reliability of CBCT measurements using a custom phantom
    Palomo, J. M.
    Christopher, M.
    Hans, M. G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S422 - S424
  • [4] Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software
    Aksoy, Secil
    Kelahmet, Umay
    Hincal, Evren
    Oz, Ulas
    Orhan, Kaan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (04) : 777 - 784
  • [5] A comparison of craniometric methods: Reliability of 3D scanning methods to direct hand-held measurements
    Hoffman, Megan R.
    Hammerl, Emily E.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2018, 165 : 122 - 122
  • [6] Probing accuracy of 3D measurements
    Kasparaitis, A.
    Sukys, A.
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE OF DAAAM BALTIC INDUSTRIAL ENGINEERING - ADDING INNOVATION CAPACITY OF LABOUR FORCE AND ENTREPRENEUR, 2006, : 139 - +
  • [7] Reliability and accuracy of automatic segmentation of mandibular 3D models on linear measurements
    Poleti, Marcelo Lupion
    Fernandes, Thais Maria Freire
    Moretti, Marcela Rodrigues
    Puzinato, Lucas Ramos
    Slaviero, Thiago Vinicius Sehn
    Rubira-Bullen, Izabel Regina Fischer
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (11) : 6335 - 6346
  • [8] Reliability and accuracy of automatic segmentation of mandibular 3D models on linear measurements
    Marcelo Lupion Poleti
    Thais Maria Freire Fernandes
    Marcela Rodrigues Moretti
    Lucas Ramos Puzinato
    Thiago Vinícius Sehn Slaviero
    Izabel Regina Fischer Rubira-Bullen
    Clinical Oral Investigations, 2021, 25 : 6335 - 6346
  • [9] Accuracy of linear measurements using three imaging modalities: two lateral cephalograms and one 3D model from CBCT data
    Pittayapat, Pisha
    Bornstein, Michael M.
    Nozu Imada, Thais Sumie
    Coucke, Wim
    Lambrichts, Ivo
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (02) : 202 - 208
  • [10] Accuracy of Linear Craniometric Measurements Obtained from Laser Scanning Created 3D Models of Dry Skulls
    Toneva, Diana
    Nikolova, Silviya
    Georgiev, Ivan
    Tchorbadjieff, Assen
    ADVANCED COMPUTING IN INDUSTRIAL MATHEMATICS, 2017, 681 : 215 - 229