Experimental study of patient specific kink in arterio-venous graft using particle image velocimetry

被引:0
|
作者
Van Canneyt, K.
Kaminsky, R.
Antiga, L.
Tordoir, J.
Verdonck, P.
Eloot, S.
机构
[1] Univ Ghent, Inst Biomed Technol, B-9000 Ghent, Belgium
[2] Mario Negri Inst Pharmacol Res, Bioengn Dept, Bergamo, Italy
[3] Maastricht Univ Hosp, Dept Surg, Maastricht, Netherlands
来源
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:710 / 710
页数:1
相关论文
共 50 条
  • [1] Successful use of arterio-venous graft for hemodialysis in patient with hemophilia
    Amberker, Deepa
    Li, Ting Ting
    Rampure, Ritesh
    HEMODIALYSIS INTERNATIONAL, 2018, 22 : S88 - S91
  • [2] Experimental evaluation of the patient-specific haemodynamics of an aortic dissection model using particle image velocimetry
    Franzetti, Gaia
    Bonfanti, Mirko
    Homer-Vanniasinkam, Shervanthi
    Diaz-Zuccarini, Vanessa
    Balabani, Stavroula
    JOURNAL OF BIOMECHANICS, 2022, 134
  • [3] Experimental study on flow in the impeller of low specific speed pump using particle image velocimetry
    Shao, Chun-Lei
    Gu, Bo-Qin
    Huang, Xing-Lu
    Zhou, Jian-Feng
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2010, 25 (09): : 2091 - 2096
  • [4] A longitudinal study of the arterio-venous fistula maturation of a single patient over 15 weeks
    Colley, Eamonn
    Carroll, John
    Anne, Simmons
    Shannon, Thomas
    Ramon, Varcoe
    Tracie, Barber
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2022, 21 (04) : 1217 - 1232
  • [5] A longitudinal study of the arterio-venous fistula maturation of a single patient over 15 weeks
    Eamonn Colley
    John Carroll
    Simmons Anne
    Thomas Shannon
    Varcoe Ramon
    Barber Tracie
    Biomechanics and Modeling in Mechanobiology, 2022, 21 : 1217 - 1232
  • [6] Using Ultrasound in Performing Image-Guided Interventions on Malfunctioning Arterio-Venous Hemodialysis Shunts
    Viets, R.
    Patel, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [7] High-grade bacteremia in a patient with infected upper arm arterio-venous graft: resolution of the bacteremia upon graft ligation only
    Gharaibeh, Kamel A.
    Baldwin, Zachary
    Fueloep, Tibor
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (02): : E8 - E9
  • [8] Influence of Wall Compliance on the Flow Patterns in a Patient-Specific Brachio-Cephalic Arterio-Venous Fistula
    Alam, Neda
    Newport, David
    BIOMECHANICS, 2022, 2 (02): : 158 - 173
  • [9] Experimental study on a zigzagging bubble using tomographic particle image velocimetry with shadow image reconstruction
    She, Wen-Xuan
    Gao, Qi
    Zuo, Zheng-Yu
    Liao, Xiang-Wei
    Zhao, Liang
    Zhang, Ling-Xin
    Nie, De-Ming
    Shao, Xue-Ming
    PHYSICS OF FLUIDS, 2021, 33 (08)
  • [10] Estimation of Arterio-Venous Access Blood Flow in Hemodialysis Patients using Video Image Processing Technique
    Zhu, Fansan
    Williams, Schantel
    Putnam, Hannah
    Campos, Israel
    Ma, Jie
    Johnson, Camille
    Kappel, Franz
    Kotanko, Peter
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 207 - 210