Implementing cost-effective 3-dimensional ultrasound using visual probe localization

被引:0
|
作者
Ali, Aziah [1 ]
Logeswaran, Rajasvaran
机构
[1] Multimedia Univ, Fac IT, Cyberjaya 63100, Selangor, Malaysia
[2] Multimedia Univ, Fac Engn, Cyberjaya 63100, Selangor, Malaysia
关键词
3-dimensional ultrasound; camera calibration; 3-dimensional tracking;
D O I
10.1007/s10278-006-0624-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article proposes a set-up for a 3-dimensional ultrasound system using visual probe localization on the conventional 2-dimensional ultrasound machines readily available in most hospitals. A calibrated digital camera is used for probe-tracking (localization) purposes, whereas ultrasound probe calibration is implemented using a purpose-built phantom. The calibration steps and results are detailed here. The overall system is proven effective in clinical trials through scanning of human organs. Results obtained show successful, accurate 3-dimensional representations using this simple cost-effective set-up.
引用
下载
收藏
页码:352 / 366
页数:15
相关论文
共 50 条
  • [1] Implementing Cost-effective 3-Dimensional Ultrasound Using Visual Probe Localization
    Aziah Ali
    Rajasvaran Logeswaran
    Journal of Digital Imaging, 2007, 20 : 352 - 366
  • [2] A visual probe localization and calibration system for cost-effective computer-aided 3D ultrasound
    Ali, Aziah
    Logeswaran, Rajasvaran
    COMPUTERS IN BIOLOGY AND MEDICINE, 2007, 37 (08) : 1141 - 1147
  • [3] Efficient 3-dimensional localization for RFID systems using jumping probe
    Chen, Honglong
    Ma, Guolei
    Wang, Zhibo
    Yu, Jiguo
    Shi, Leyi
    Jiang, Xiangyuan
    PERVASIVE AND MOBILE COMPUTING, 2017, 41 : 300 - 318
  • [4] Is genetic ultrasound cost-effective?
    DeVore, GR
    SEMINARS IN PERINATOLOGY, 2003, 27 (02) : 173 - 182
  • [5] A 3-Dimensional Printed Ultrasound Probe Visuospatial Trainer
    McKenna, Ryan T.
    Dove, Jesse C.
    Ratzlaff, Robert A.
    Diaz-Gomez, Jose L.
    Cox, Daniel J.
    Simon, Leslie V.
    ULTRASOUND QUARTERLY, 2018, 34 (02) : 103 - 105
  • [6] 3-DIMENSIONAL ULTRASONIC DIAGNOSIS OF GASTROINTESTINAL LESIONS USING ENDOSCOPIC ULTRASOUND PROBE
    NISHIMURA, K
    NIWA, Y
    TSUKAMOTO, Y
    GOTO, H
    HASE, S
    MIYATA, A
    YOSHIDA, M
    HASEGAWA, N
    HAYAKAWA, T
    GASTROENTEROLOGY, 1995, 108 (04) : A515 - A515
  • [7] Establishing a Cost-Effective 3-Dimensional Printing Laboratory for Anatomical Modeling and Simulation An Institutional Experience
    Clifton, William
    Damon, Aaron
    Nottmeier, Eric
    Pichelmann, Mark
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2021, 16 (03): : 213 - 220
  • [8] Coronary Flow Assessment Using 3-Dimensional Ultrafast Ultrasound Localization Microscopy
    Demeulenaere, Oscar
    Sandoval, Zulma
    Mateo, Philippe
    Dizeux, Alexandre
    Villemain, Olivier
    Gallet, Romain
    Ghaleh, Bijan
    Deffieux, Thomas
    Demene, Charlie
    Tanter, Mickael
    Papadacci, Clement
    Pernot, Mathieu
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (07) : 1193 - 1208
  • [9] Implementing Cost-Effective Assistive Computer Technology
    Mosley, Shelley
    LIBRARY JOURNAL, 2012, 137 (02) : 78 - 78
  • [10] Cost-Effective Localization of Mobile Robots Using Ultrasound Beacons and Differential Time-of-Flight Measurement
    Al-Hadithi, Basil Mohammed
    Pastor, Carlos
    APPLIED SCIENCES-BASEL, 2024, 14 (17):