Simultaneous determination of bromate, chlorite and haloacetic acids by two-dimensional matrix elimination ion chromatography with coupled conventional and capillary columns

被引:33
|
作者
Teh, Hui Boon [1 ]
Li, Sam Fong Yau [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] NUS Environm Res Inst, Singapore 117411, Singapore
[3] Peking Univ, Shenzhen Grad Sch, Sch Environm & Energy, Shenzhen Engn Lab Ecoefficient Polysilicate Mat, Shenzhen 518055, Peoples R China
基金
新加坡国家研究基金会;
关键词
Bromate; Haloacetic acids; Ion-chromatography; Two-dimensional; Capillary; DRINKING-WATER; BY-PRODUCTS; TRICHLOROACETIC-ACID; DICHLOROACETIC ACID; MASS-SPECTROMETRY; CHLORINATION; OXYHALIDES; OZONATION; BROMIDE; LIVER;
D O I
10.1016/j.chroma.2015.01.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new, highly sensitive and reliable two-dimensional matrix elimination ion chromatography (IC) method was developed for simultaneous detection of bromate, chlorite and five haloacetic acids. This method combined the conventional IC in first dimension with capillary IC in the second dimension coupled with suppressed conductivity detection. The first dimension utilizes a high capacity column to partially resolve matrix from target analytes. By optimizing the cut window, the target analytes were selectively cut and trapped in a trap column through the use of a six-port valve, while the separated matrix were diverted to waste. The trapped target analytes were delivered on to the capillary column for further separation and detection. Temperature programming was used to improve selectivity in second dimension column to obtain complete resolution of the target analytes. Compared to the performance of one-dimensional IC, the two-dimensional approach resulted in a significant increase in sensitivity for all target analytes with limit of detection ranging from 0.30 to 0.64 mu g/L and provided more reliable analysis due to second column confirmation. Good linearity was obtained for all the target analytes with correlation coefficients >0.998. The proposed method was successfully applied to the determination of oxyhalides and haloacetic acids in various matrices with recoveries ranging from 90 to 116% and RSD less than 6.1%. The method allows direct injection of samples and the use of columns with different selectivity, thus significantly reduces the level of false positive results. The method is fully automated and simple, making it practical for routine monitoring of water quality. The satisfactory results also demonstrated that the two-dimensional matrix elimination method coupled with capillary IC is a promising approach for detection of trace substances in complex matrices. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [1] Determination of haloacetic acids in drinking water using matrix elimination ion chromatography
    Fisher, Carl
    Lin, Rong
    Bahten, Kris
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [2] Simultaneous determination of trace level bromate and chlorinated haloacetic acids in bottled drinking water by ion chromatography
    Liu, YJ
    Mou, SF
    MICROCHEMICAL JOURNAL, 2003, 75 (02) : 79 - 86
  • [3] Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection
    Creed, JT
    Magnuson, ML
    Brockhoff, CA
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) : 2059 - 2063
  • [4] Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection
    Creed, John T.
    Magnuson, Matthew L.
    Brockhoff, Carol A.
    Environmental Science and Technology, 1997, 31 (07): : 2059 - 2063
  • [5] Determination of Phosphite, Phosphate, Glyphosate and Aminomethylphosphonic Acid by Two-Dimensional Ion Chromatography System Coupled with Capillary Ion Chromatography
    Qiu Hui-Min
    Geng Jin-Ju
    Han Chao
    Ren Hong-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (12) : 1910 - 1913
  • [6] Direct determination of trace-level haloacetic acids in drinking water by two-dimensional ion chromatography with suppressed conductivity
    Verrey, Dominique
    Louyer, Mari-Vorgan
    Thomas, Olivier
    Baures, Estelle
    MICROCHEMICAL JOURNAL, 2013, 110 : 608 - 613
  • [7] Determination of bromate in sea water using multi-dimensional matrix-elimination ion chromatography
    Zakaria, Philip
    Bloomfield, Carrie
    Shellie, Robert A.
    Haddad, Paul R.
    Dicinoski, Greg W.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (50) : 9080 - 9085
  • [8] Direct injection ion chromatography for the control of chlorinated drinking water: simultaneous estimation of nine haloacetic acids and quantitation of bromate, chlorite and chlorate along with the major inorganic anions
    Garcia-Villanova, Rafael J.
    Raposo Funcia, Cesar
    Oliveira Dantas Leite, M. Vilani
    Toruno Fonseca, Ivania M.
    Espinosa Nieto, Miguel
    Espuelas India, Javier
    JOURNAL OF WATER AND HEALTH, 2014, 12 (03) : 443 - 451
  • [9] Applications of two-dimensional ion chromatography for analytes determination in environmental matrix: A review
    Yang, Yang
    Pan, Huimei
    Li, Xiao
    Luo, Wang
    Bharti, Bandna
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1694
  • [10] Trace anion determination in concentrated hydrofluoric acid solutions by two-dimensional ion chromatography - I. Matrix elimination by ion-exclusion chromatography
    Vermeiren, K
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) : 60 - 65