Role of B-scan ultrasonography in the localization of intraocular foreign bodies in the anterior segment: a report of three cases

被引:5
|
作者
Wang, Kaijun [1 ,2 ]
Liu, Jun [1 ]
Chen, Min [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Eye Ctr, Hangzhou 310009, Zhejiang, Peoples R China
[2] Zhejiang Prov Key Lab Ophthalmol, Hangzhou, Zhejiang, Peoples R China
来源
BMC OPHTHALMOLOGY | 2015年 / 15卷
基金
中国国家自然科学基金;
关键词
Ocular trauma; Intraocular foreign bodies; B-scan ultrasonography; Localization; OPTICAL COHERENCE TOMOGRAPHY; ULTRASOUND BIOMICROSCOPY; COMPUTED-TOMOGRAPHY; BODY; MANAGEMENT;
D O I
10.1186/s12886-015-0076-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The accurate localization of intraocular foreign bodies (IOFBs) is very important for the management of ocular trauma patients. B-scan ultrasonography is usually used to detect IOFBs in the posterior segment. Here, we report three cases with IOFBs in the anterior segment near the posterior lens capsule, which were accurately localized by B-scan ultrasonography under dynamic transversal scanning. Case presentation: All three patients had a history of ocular trauma, and their clinical symptoms were compatible with the persistence of IOFBs. It was difficult to get a direct visualization of IOFBs with slit-lamp biomicroscopy because of opacities of the cornea and traumatic cataract. A computed tomography scan detected IOFBs in the anterior segment, but could not determine the exact location. Ultrasound biomicroscopy was performed but failed to show any IOFBs owing to the limited depth of penetration. B-scan ultrasonography was further applied but also failed to show any intraocular foreign bodies using axial scanning, a routine procedure of B-scan ultrasonography examination. However, using dynamic transversal scanning of B-scan ultrasonography, the accurate location of IOFBs was eventually shown to be embedded in the posterior lens cortex in case 1, adjacent to the posterior lens capsule in case 2, and located in the anterior vitreous close to the posterior lens capsule in case 3. Different surgical procedures were designed according to localization by B-scan ultrasonography, and all IOFBs were successfully removed. Conclusion: B-scan ultrasonography is a simple and effective imaging modality in the localization of IOFBs in traumatic cataract. Transversal scanning is more suitable than axial scanning to detect IOFBs in the anterior segment near the posterior lens capsule.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Role of B-scan ultrasonography in the localization of intraocular foreign bodies in the anterior segment: a report of three cases
    Kaijun Wang
    Jun Liu
    Min Chen
    [J]. BMC Ophthalmology, 15
  • [2] B-SCAN ULTRASONOGRAPHY OF ANTERIOR SEGMENT OF EYE
    LEMAY, M
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1978, 62 (09) : 651 - 656
  • [3] Role of B-Scan Ultrasonography for Posterior Segment Lesions
    Dawood, Zafar
    Mirza, Sajid Ali
    Qadeer, Abdul
    [J]. JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2008, 7 (01): : 7 - 12
  • [4] Topographic localization of an intraocular foreign body by B-scan echography
    Stefanovic, Ivan
    Dacic, Bojana
    Novak, Sasa
    Veselinovic, Dragan
    Jovanovic, Predrag
    Dzunic, Boban
    Tomasevic, Branislav
    [J]. VOJNOSANITETSKI PREGLED, 2010, 67 (03) : 213 - 215
  • [5] LOCALIZATION OF INTRAOCULAR AND INTRAORBITAL FOREIGN-BODIES BY MEANS OF A-SCAN ULTRASONOGRAPHY
    BERTENYI, A
    [J]. ULTRASONICS, 1976, 14 (04) : 183 - 185
  • [6] Three-dimensional ophthalmic contact B-scan ultrasonography of the posterior segment
    Fisher, Y
    Hanutsaha, P
    Tong, SD
    Fenster, A
    Mazarin, G
    Mandava, N
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1998, 18 (03): : 251 - 256
  • [7] A closer look at anterior segment intraocular foreign bodies
    Cooke, CA
    Mulholland, DA
    [J]. EYE, 2005, 19 (04) : 476 - 478
  • [8] A closer look at anterior segment intraocular foreign bodies
    C A Cooke
    D A Mulholland
    [J]. Eye, 2005, 19 : 476 - 478
  • [9] PROTOCOL FOR B-SCAN AND RADIOGRAPHIC FOREIGN BODY LOCALIZATION
    COLEMAN, DJ
    TROKEL, SL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 71 (01) : 84 - &
  • [10] Three-dimensional contact B-scan ultrasonography of the posterior segment in pathological myopia.
    Ciardella, AP
    Slakter, JS
    Fisher, YL
    Yannuzzi, LA
    Guyer, DR
    Fenster, A
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2828 - 2828