Removing electroencephalographic artifacts: Comparison between ICA and PCA

被引:122
|
作者
Jung, TP [1 ]
Humphries, C [1 ]
Lee, TW [1 ]
Makeig, S [1 ]
McKeown, MJ [1 ]
Iragui, V [1 ]
Sejnowski, TJ [1 ]
机构
[1] Salk Inst, Computat Neurobiol Lab, San Diego, CA 92186 USA
关键词
D O I
10.1109/NNSP.1998.710633
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Pervasive electroencephalographic (EEG) artifacts associated with blinks, eye-movements, muscle noise, cardiac signals, and line noise poses a major challenge for EEG interpretation and analysis. Here, we propose a generally applicable method for removing a wide variety of artifacts from EEG records based on an extended version of an Independent Component Analysis (ICA) algorithm [2, 12] for performing blind source separation on linear mixtures of independent source signals. Our results show that ICA can effectively separate and remove contamination from a wide variety of artifactual sources in EEG records with results comparing favorably to those obtained using Principal Component Analysis.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 50 条
  • [1] Removing electroencephalographic artifacts by blind source separation
    Jung, TP
    Makeig, S
    Humphries, C
    Lee, TW
    McKeown, MJ
    Iragui, V
    Sejnowski, TJ
    [J]. PSYCHOPHYSIOLOGY, 2000, 37 (02) : 163 - 178
  • [2] Removing Electroencephalographic Artifacts by Independent Components Analysis
    Nguyen Thi Minh Huong
    Truong Quang Dang Khoa
    Nguyen Thi Kim Cuong
    Vo Quang Ha
    Nguyen Huu Pho
    Le Tu Quoc Tuan
    Ngo Thanh Hoan
    Huynh Quang Linh
    Vo Van Toi
    [J]. THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 287 - +
  • [3] PCA and ICA processing methods for removal of artifacts and noise in electrocardiograms: A survey and comparison
    Chawla, M. P. S.
    [J]. APPLIED SOFT COMPUTING, 2011, 11 (02) : 2216 - 2226
  • [4] Extended ICA removes artifacts from electroencephalographic recordings
    Jung, TP
    Humphries, C
    Lee, TW
    Makeig, S
    McKeown, MJ
    Iragui, V
    Sejnowski, TJ
    [J]. ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 10, 1998, 10 : 894 - 900
  • [5] Study of removal of artifacts in MEG using PCA and ICA
    Gao, Li
    Huang, Li-Yu
    Ding, Cui-Ling
    [J]. Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2007, 34 (06): : 939 - 943
  • [6] Extracting structural damage features: Comparison between PCA and ICA
    Zhong, Luo
    Song, Huazhu
    Han, Bo
    [J]. INTELLIGENT COMPUTING IN SIGNAL PROCESSING AND PATTERN RECOGNITION, 2006, 345 : 840 - 845
  • [7] Method of removing EOG artifacts from EEG based on ICA
    Chen, LW
    Bi, GT
    Sun, M
    Liao, J
    Li, XY
    [J]. ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 5, 2005, : 458 - 460
  • [8] Method of removing ECG artifacts from EEG based on ICA
    Li, XY
    [J]. ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 1900 - 1903
  • [9] Comparison of PCA and ICA in color recognition
    Laamanen, H
    Jaaskelainen, T
    Parkkinen, JPS
    [J]. INTELLIGENT ROBOTS AND COMPUTER VISION XIX: ALGORITHMS, TECHNIQUES, AND ACTIVE VISION, 2000, 4197 : 367 - 377
  • [10] COMPARISON OF PCA AND ICA IN FACE RECOGNITION
    Luo, Bing
    Hao, Yu-Jie
    Zhang, Wei-Hua
    Liu, Zhi-Shen
    [J]. 2008 INTERNATIONAL CONFERENCE ON APPERCEIVING COMPUTING AND INTELLIGENCE ANALYSIS (ICACIA 2008), 2008, : 241 - +