Towards Characterising the Size of Microscopic Optical Absorbers Using Optoacoustic Emission Spectroscopy

被引:4
|
作者
Gertsch, A. G. [1 ]
Bush, N. L. [1 ]
Birtill, D. C. C. [1 ]
Bamber, J. C. [1 ]
机构
[1] Inst Canc Res, Joint Dept Phys, Surrey, England
关键词
Optoacoustic Imaging; Absorber Size; Optoacoustic Emission Spectroscopy; Tissue Characterisation; Photoacoustics; TUMOR ANGIOGENESIS; IN-VIVO; RECONSTRUCTION; CANCER;
D O I
10.1117/12.844188
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To assess the malignancy and progression of a tumour, parameters such as the size and number density of the microvessels are expected to be important. The optical absorption due to the blood that fills the microvessels can be visualised by optoacoustic imaging (OA). We have previously reported that increasing the inhomogeneity of absorption within a large absorbing volume produces evidence of reduced acoustic coherence which results in improved contrast and boundary detectability. Here we propose to take advantage of the expectation that the detailed nature of the inhomogeneity should influence the frequency spectrum of the OA signal. The overall aim of this work is to determine whether an analysis of the frequency spectrum of the emitted optoacoustic signal can be used to determine the scale of this absorption inhomogeneity, in particular parameters such as the characteristic size and separation of the absorbers (microvessels). In the preliminary study reported here, various gelatine-intralipid phantoms containing cylindrical wall-less tubes filled with an ink solution were measured in water with a linear array ultrasound detector, using pulsed-illumination that had been adjusted for an optimal distribution of light fluence with depth. Simulations of the experiments were also conducted, using a time domain acoustic propagation method. The results confirm that optoacoustic signals bear information on the sizes and distribution of the absorbers in their frequency spectra. It is shown that a simple way to determine the diameter of a single cylindrical absorber is to estimate the quefrency of the peak in the cepstrum of the measured signal. Further work is proposed to extend this to the statistical estimation of mean diameter and mean separation for an ensemble of similar absorbers and to absorbers with a diameter that is smaller than the axial resolution of the acoustic receiver.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Characterising the radio frequency plasma source for glow discharge optical emission spectroscopy
    Payling, Richard
    Chapon, Patrick
    Bonnot, Olivier
    Belenguer, Philippe
    Guillot, Philippe
    Pitchford, Leanne C.
    Therese, Laurent
    Michler, Johann
    Aeberhard, Max
    ISIJ International, 2002, 42 (SUPPL.)
  • [2] Optical emission spectroscopy of microscopic gas discharges using a high-pressure scanning tunneling microscope
    Möller, D
    Eckert, R
    Haefke, H
    Güntherodt, HJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2000, 18 (02): : 644 - 647
  • [3] Seasoning Optimization by Using Optical Emission Spectroscopy
    Shiga, Masahiro
    Omine, Haruki
    Kitsunezuka, Masaki
    Moki, Hironori
    Kataoka, Yuki
    Matsuzawa, Takahito
    Suzuki, Yasuhisa
    Fukazawa, Yusuke
    Makita, Tsuyoshi
    Takasawa, Kazuyuki
    Yamamoto, Takuo
    Funakubo, Takao
    2020 INTERNATIONAL SYMPOSIUM ON SEMICONDUCTOR MANUFACTURING (ISSM), 2020,
  • [4] Plasma etch modeling using optical emission spectroscopy
    J Vac Sci Technol A, 3 pt 2 (1901):
  • [5] Plasma etch modeling using optical emission spectroscopy
    Chen, RW
    Huang, H
    Spanos, CJ
    Gatto, M
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1996, 14 (03): : 1901 - 1906
  • [6] Characterization of glowing cotacts using optical emission spectroscopy
    Zhou, Xin
    Shea, John
    PROCEEDINGS OF THE 53RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2007, : 98 - +
  • [7] In vivo monitoring of vascularization and oxygenation of tumor xenografts using optoacoustic microscopy and diffuse optical spectroscopy
    Akhmedzhanova, K. G.
    Kurnikov, A. A.
    Khochenkov, D. A.
    Khochenkova, Yu A.
    Glyavina, A. M.
    Kazakov, V. V.
    Yudintsev, A., V
    Maslennikova, A., V
    Turchin, I., V
    Subochev, P., V
    Orlova, A. G.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (11) : 5695 - 5708
  • [8] NBN FILM DEPOSITION USING OPTICAL-EMISSION SPECTROSCOPY
    BHUSHAN, M
    IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) : 843 - 846
  • [9] Mechanisms of amino acid formation using optical emission spectroscopy
    Miyakawa, S
    Sawaoka, AB
    Ushio, K
    Kobayashi, K
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (09) : 6853 - 6857
  • [10] Endpoint Detection Using Optical Emission Spectroscopy in TSV Fabrication
    Gu, Ja Myung
    Thadesar, Paragkumar A.
    Dembla, Ashish
    Hong, Sang Jeen
    Bakir, Muhannad S.
    May, Gary S.
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL INTERCONNECT TECHNOLOGY CONFERENCE (IITC), 2013,