Sensitivity of quantitative photoacoustic tomography inversion schemes to experimental uncertainty

被引:1
|
作者
Fonseca, Martina [1 ]
Saratoon, Teedah [1 ]
Zeqiri, Bajram [2 ]
Beard, Paul [1 ]
Cox, Ben [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Gower St, London WC1E 6BT, England
[2] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
关键词
quantitative photoacoustic imaging; virtual phantom studies; model-based inversion; unmixing strategies; sources of uncertainty; accuracy; OPTICAL-PROPERTIES; DISTRIBUTIONS; SCATTERING;
D O I
10.1117/12.2210916
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The ability to accurately quantify chromophore concentration from photoacoustic images would have a major impact on pre-clinical and clinical imaging. Recent years have seen significant advances in the theoretical understanding of quantitative photoacoustic imaging and in the development of model-based inversion strategies that overcome issues such as non-uniqueness and non-linearity. Nevertheless, their full in vivo implementation has not successfully been achieved, partially because experimental uncertainties complicate the transition. In this study, a sensitivity analysis is performed to assess the impact on accuracy of having uncertainty in critical experimental parameters such as scattering, beam diameter, beam position and calibration factor. This study was performed using two virtual phantoms, at one illumination and four optical wavelengths. The model-based inversion was applied in 3 variants - one just inverting for chromophores and two others further inverting for either a scaling factor or the scatterer concentration. The performance of these model-based inversions is also compared to linear unmixing strategies - with and without fluence correction. The results show that experimental uncertainties in a priori fixed parameters - especially calibration factor and scatterer concentration - significantly affect accuracy of model-based inversions and therefore measures to ameliorate this uncertainty should be considered. Including a scaling parameter in the inversion appears to improve quantification estimates. Furthermore, even with realistic levels of experimental uncertainty in model-based input parameters, they outperform linear unmixing approaches. If parameter uncertainty is large and has significant impact on accuracy, the parameter can be included as an unknown in model-based schemes.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation
    Liu, Yubin
    Jiang, Huabei
    Yuan, Zhen
    [J]. MEDICAL PHYSICS, 2016, 43 (07) : 3987 - 3997
  • [2] Experimental validation of a Monte-Carlo-based inversion scheme for 3D quantitative photoacoustic tomography
    Buchmann, Jens
    Kaplan, Bernhard A.
    Prohaska, Steffen
    Laufer, Jan
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [3] Quantitative Photoacoustic Tomography
    Gao, Hao
    Osher, Stanley
    Zhao, Hongkai
    [J]. MATHEMATICAL MODELING IN BIOMEDICAL IMAGING II: OPTICAL, ULTRASOUND, AND OPTO-ACOUSTIC TOMOGRAPHIES, 2012, 2035 : 131 - 158
  • [4] Quantitative photoacoustic tomography
    Yuan, Zhen
    Jiang, Huabei
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1900): : 3043 - 3054
  • [5] Statistical independence in nonlinear model-based inversion for quantitative photoacoustic tomography
    An, Lu
    Saratoon, Teedah
    Fonseca, Martina
    Ellwood, Robert
    Cox, Ben
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (11): : 5297 - 5310
  • [6] Quantitative Fluorescence Photoacoustic Tomography
    Ren, Kui
    Zhao, Hongkai
    [J]. SIAM JOURNAL ON IMAGING SCIENCES, 2013, 6 (04): : 2404 - 2429
  • [7] Quantitative Photoacoustic Tomography Using Iteratively Refined Wavefield Reconstruction Inversion: A Simulation Study
    Ranjbaran, Seyed Mohsen
    Aghamiry, Hossein S.
    Gholami, Ali
    Operto, Stephane
    Avanaki, Kamran
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (02) : 874 - 885
  • [8] Fiber endface photoacoustic generator for quantitative photoacoustic tomography
    Yang, Guang
    Huan, Hengbo
    Luo, Hongbo
    Kou, Sitai
    Amidi, Eghbal
    Achilefu, Samuel
    Zhu, Quing
    [J]. OPTICS LETTERS, 2021, 46 (11) : 2706 - 2709
  • [9] Monte-Carlo-based inversion scheme for 3D quantitative photoacoustic tomography
    Kaplan, Bernhard A.
    Buchmann, Jens
    Prohaska, Steffen
    Laufer, Jan
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [10] Experimental investigation of target and transducer effects on quantitative image reconstruction in photoacoustic tomography
    Gamelin, John
    Aguirre, Andres
    Huang, Fei
    Maurudis, Anastasios
    Castillo, Diego
    Wang, Lihong V.
    Zhu, Quing
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007, 2007, 6437