Effect of scan duration on lesion detectability in PET oncology imaging

被引:0
|
作者
Cheng, PM [1 ]
Kinahan, PE [1 ]
Comtat, C [1 ]
Kim, JS [1 ]
Lartizien, C [1 ]
Lewellen, TK [1 ]
机构
[1] Univ Washington, Seattle, WA 98195 USA
来源
2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2 | 2004年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We have simulated 2D PET acquisitions of an anthropomorphic phantom with numerous spherical target lesions. The diameters of the lesions were varied from 1.0 to 3.0 cm, and the contrast ratios of the lesions were varied from 1.5 to 4.0. Noise-free scans were simulated with an analytical simulator. Poisson noise was added to simulate scan durations ranging from I to 10 minutes, using noise equivalent count rates previously measured in 2D whole-body acquisitions of an anthropomorphic phantom. The average detectability of each target lesion under each condition was calculated using a non-prewhitening g matched filter. Our results demonstrate the variation of the minimum scan duration required to detect a target of a given size and contrast ratio, for any fixed threshold of detectability.
引用
收藏
页码:1432 / 1435
页数:4
相关论文
共 50 条
  • [1] Effect of patient thickness and scan duration on lesion detectability in PET oncology imaging
    Cheng, PM
    Kinahan, PE
    Comtat, C
    Lartizien, C
    Lewellen, TK
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 960 - 968
  • [2] Effect of emission scan duration on lesion detectability and noise on dedicated breast PET in breast cancer screening
    Miyake, Kanae
    Nakamoto, Yuji
    Torii, Masae
    Takakura, Kyoko
    Ishimori, Takayoshi
    Kataoka, Masako
    Matsumoto, Yoshiaki
    Isoda, Hiroyoshi
    Toi, Masakazu
    Togashi, Kaori
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [3] Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability
    Halpern, BS
    Dahlbom, M
    Quon, A
    Schiepers, C
    Waldherr, C
    Silverman, DH
    Ratib, O
    Czernin, J
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (05) : 797 - 801
  • [4] PET scan imaging in oncology
    Jerusalem, G
    Hustinx, R
    Beguin, Y
    Fillet, G
    EUROPEAN JOURNAL OF CANCER, 2003, 39 (11) : 1525 - 1534
  • [5] A Phantom Design and Assessment of Lesion Detectability in PET Imaging
    Wollenweber, Scott D.
    Kinahan, Paul E.
    Alessio, Adam M.
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [6] Impact of improved PET spatial and timing resolution on lesion detectability in oncology
    Surti, Suleman
    Reddin, Janet
    Scheuermann, Joshua
    Daube-Witherspoon, Margaret
    Conti, Maurizio
    Casey, Michael
    Karp, Joel
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [7] Application of Lesion Detectability Phantoms for Model Observer Assessment in PET Imaging
    Wollenweber, Scott
    Kinahan, Paul
    Alessio, Adam
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [8] Improving lesion detectability in PET imaging with a penalized likelihood reconstruction algorithm
    Wangerin, Kristen A.
    Ahn, Sangtae
    Ross, Steven G.
    Kinahan, Paul E.
    Manjeshwar, Ravindra M.
    MEDICAL IMAGING 2015: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2015, 9416
  • [9] Effect of Varying Number of OSEM Subsets on PET Lesion Detectability
    Morey, A. Michael
    Kadrmas, Dan J.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2013, 41 (04) : 268 - 273
  • [10] The effect of attenuation on lesion detection in PET oncology
    Bai, CY
    Wang, RF
    Kinahan, P
    Shao, L
    Ye, JH
    Da Silva, AJ
    Zhao, Z
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2124 - 2128