Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study

被引:3
|
作者
Pichtchoulin, Sara [1 ]
Selmeryd, Ingrid [2 ]
Freyhult, Elisabeth [3 ]
Hedberg, Par [1 ,4 ]
Selmeryd, Jonas [1 ,4 ]
机构
[1] Vastmanland Cty Hosp, Dept Clin Physiol, Vasteras, Sweden
[2] Vastmanland Cty Hosp, Dept Infect Dis, Vasteras, Sweden
[3] Vastmanland Cty Hosp, Dept Microbiol, Vasteras, Sweden
[4] Uppsala Univ, Vastmanland Cty Hosp, Ctr Clin Res, Vasteras, Sweden
关键词
Staphylococcus aureus; cardiac implantable electronic device; endocarditis; pacemaker; INFECTION; SEPSIS; RISK; OUTCOMES; HRS;
D O I
10.48101/ujms.v126.5653
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations. Methods: All CIED carriers with SAB, excluding clinical pocket infections, in the County of Vastmanland during 2010-2017 were reviewed retrospectively. Results: There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases. Conclusions: During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Staphylococcus aureus bacteraemia, cardiac implantable electronic device, and the risk of endocarditis: a retrospective population-based cohort study
    Berge, Andreas
    Carlsen, Casper
    Petropoulos, Alexandros
    Gadler, Fredrik
    Rasmussen, Magnus
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (05) : 583 - 591
  • [2] Staphylococcus aureus bacteraemia, cardiac implantable electronic device, extraction, and the risk of recurrent infection; a retrospective population-based cohort study
    Berge, Andreas
    Carlsen, Casper
    Petropoulos, Alexandros
    Gadler, Fredrik
    Rasmussen, Magnus
    [J]. INFECTIOUS DISEASES, 2024, 56 (07) : 543 - 553
  • [3] Staphylococcus aureus bacteraemia, cardiac implantable electronic device, and the risk of endocarditis: a retrospective population–based cohort study
    Andreas Berge
    Casper Carlsén
    Alexandros Petropoulos
    Fredrik Gadler
    Magnus Rasmussen
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2023, 42 : 583 - 591
  • [4] Incidence of Staphylococcus aureus Bacteremia in Patients Following Implantation of Cardiac Implantable Electronic Devices: A Danish Nationwide Cohort Study
    Bengtsen, Kasper Hotoft
    Falkentoft, Alexander Christian
    Le, Melanie Vuong
    Haugan, Ketil
    Philbert, Berit Thornvig
    Johansen, Jens Brock
    Torp-Pedersen, Christian
    Riahi, Sam
    Nielsen, Jens Cosedis
    Larroude, Charlotte
    Petersen, Andreas
    Larsen, Anders Rhod
    Ostergaard, Lauge
    Fosbol, Emil
    Bruun, Niels Eske
    Ruwald, Anne-Christine
    [J]. OPEN FORUM INFECTIOUS DISEASES, 2024, 11 (09):
  • [5] Staphylococcus aureus bacteremia in Danish patients with cardiac implantable electronic devices: an explorative epidemiological study
    Bengtsen, K.
    Fosboel, E.
    Haugan, K.
    Philbert, B. T.
    Johansen, J. B.
    Torp-Pedersen, C.
    Riahi, S.
    Nielsen, J. C.
    Petersen, A.
    Larsen, A. R.
    Bruun, N. E.
    Ruwald, A. C.
    [J]. EUROPEAN HEART JOURNAL, 2022, 43 : 1677 - 1677
  • [6] Non-betahemolytic streptococcal bacteremia, cardiac implantable electronic device, endocarditis, extraction, and outcome; a population-based retrospective cohort study
    Berge, Andreas
    Lundin, Johannes
    Blackberg, Anna
    Sunnerhagen, Torgny
    Rasmussen, Magnus
    [J]. INFECTION, 2024,
  • [7] Staphylococcus aureus bacteremia, cardiac implantable electronic device, extraction, and the risk of recurrence
    Berge, Andreas
    Strand, Rasmus
    Nilson, Bo
    Naucler, Pontus
    Rasmussen, Magnus
    [J]. JOURNAL OF INFECTION, 2022, 84 (05) : E67 - E69
  • [8] A Population-Based Evaluation of Polymicrobial Staphylococcus aureus Bacteremia
    Hindy, Joya-Rita
    Quintero-Martinez, Juan A.
    Lahr, Brian D.
    DeSimone, Daniel C.
    Baddour, Larry M.
    [J]. PATHOGENS, 2022, 11 (12):
  • [9] Temporal Trends in the Incidence of Staphylococcus aureus Bacteremia in Olmsted County, Minnesota, 1998 to 2005: A Population-Based Study
    El Atrouni, Wissam I.
    Knoll, Bettina M.
    Lahr, Brian D.
    Eckel-Passow, Jeanette E.
    Sia, Irene G.
    Baddour, Larry M.
    [J]. CLINICAL INFECTIOUS DISEASES, 2009, 49 (12) : E130 - E138
  • [10] Incidence of Monomicrobial Staphylococcus aureus Bacteremia: A Population-Based Study in Olmsted County, Minnesota-2006 to 2020
    Hindy, Joya Rita
    Quintero-Martinez, Juan A.
    Lahr, Brian D.
    Palraj, Raj
    Go, John R.
    Fida, Madiha
    Abu Saleh, Omar M.
    Arshad, Verda
    Talha, Khawaja M.
    DeSimone, Daniel C.
    Sohail, M. Rizwan
    Baddour, Larry M.
    [J]. OPEN FORUM INFECTIOUS DISEASES, 2022, 9 (07):