Compact hard X-ray imaging system with a large FOV

被引:0
|
作者
Katsuragawa, Miho [1 ,2 ]
Takeda, Shin'ichiro [3 ]
Sato, Goro [1 ]
Harayama, Atsushi [1 ]
Kennedy, Patrick Kenneth [3 ]
Deasy, Kieran [3 ]
Watanabe, Shin [1 ,2 ]
Takahashi, Tadayuki [1 ,2 ]
机构
[1] ISAS JAXA, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2298510, Japan
[2] Univ Tokyo, Dept Phys, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1130033, Japan
[3] OIST, 1919-1 Tancha, Onna Son, Okinawa 9040495, Japan
关键词
CdTe-DSD; Coded mask; Uniformly Redundant Arrays; DETECTOR;
D O I
10.1117/12.2240497
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a compact hard X-ray imaging system composed of a cadmium telluride double-sided strip detector (CdTe-DSD) and a coded mask. We investigate the imaging performance using two different coded masks with different sizes and patterns. In our system, a CdTe-DSD of pitch 250 pm is used in conjunction with a coded mask is placed 70-100 mm above the detector to form a compact imaging system. We obtained an angular resolution of up to 11.8 arc min, as measured from gamma-ray lines of point-like radioactive isotope sources. This is consistent with that expected from the geometry. The energy resolution is 1.7 keV (FWHM) at 60 keV and the energy range of imaging is from 5 keV to 122 keV. These results agree very well with Monte Carlo simulations of the detector.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hard x-ray imaging system for XEUS
    Kunieda, Hideyo
    Takahashi, Tadayuki
    Kokubun, Motohide
    Nakazawa, Kazuhiro
    Ogasaka, Yasushi
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [2] Compact digital X-ray imaging system
    Zheng, Yu-Quan
    Wang, Hui
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2008, 16 (04): : 591 - 597
  • [3] A COMPACT HARD X-RAY SOURCE FOR MEDICAL IMAGING AND BIOMOLECULAR STUDIES
    CLINE, DB
    GARREN, AA
    GREEN, MA
    KOLONKO, J
    MADURA, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 821 - 823
  • [4] Simulation Analysis of a Pulsed Compact FLTD System for Large-Area Hard X-Ray Sources
    Zhang, PengFei
    Sun, Jianfeng
    Sun, Fengju
    Qiu, Aici
    Sun, Jiang
    Hu, Yang
    Cong, Peitian
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (05) : 803 - 807
  • [5] A compact PC-based X-ray imaging system
    Asimidis, A.
    Evangelou, I.
    Kokkas, P.
    Manthos, N.
    Triantis, F.
    Speller, R. D.
    Hall, G.
    Van der Stelt, P. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 19 - 22
  • [6] Imaging in hard X-ray astronomy
    Li, TP
    HIGH ENERGY PROCESSES AND PHENOMENA IN ASTROPHYSICS, 2003, (214): : 70 - 83
  • [7] Hard X-ray microtomography using X-ray imaging optics
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Suzuki, Yoshio
    Aoki, Sadao
    1600, Japan Society of Applied Physics (40): : 1499 - 1503
  • [8] Hard X-ray microtomography using X-ray imaging optics
    Takeuchi, A
    Uesugi, K
    Suzuki, Y
    Aoki, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (3A): : 1499 - 1503
  • [9] Laser pulse circulation system for a compact monochromatic hard X-ray source
    Ebina, F
    Fukasawa, A
    Sakamoto, F
    Ogino, H
    Uesaka, M
    Dobashi, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 241 (1-4): : 905 - 908
  • [10] Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source
    Schleede, Simone
    Bech, Martin
    Achterhold, Klaus
    Potdevin, Guillaume
    Gifford, Martin
    Loewen, Rod
    Limborg, Cecile
    Ruth, Ronald
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 525 - 529